Home |
Search |
Today's Posts |
#1
![]() |
|||
|
|||
![]()
hi
I was wanting to dispel some myths about connector losses lets assume my worst case freq 450mhz LOW /week singal work lets assume my worst coax is ether lmr400 or 600 (not imp ) so naturally i'd use typically N connectors how much do i lose if I screw in a right angle adapter? in general at the base of a radio and same question say i want to join to lengths of coax and use a small stubby f/f N connector adapter ?? lose going from a DIN to an N via a adapter?? at radio and 'inline' joining 2 coax lengths some say the loss is actually neg some say it's going to add up and the insertion loss could easily go over 1/2 db i dunno exactly how good/bad is it? and where can u get some good low loss adapters (i know of ampenol) I bought some unknowns at a flea market and they had great loss to which in that case i attribute to just poor quality thanks to all those in advance that help me put the hamster back on the wheel ml |
#2
![]() |
|||
|
|||
![]() "ml" wrote in message ... hi I was wanting to dispel some myths about connector losses lets assume my worst case freq 450mhz LOW /week singal work lets assume my worst coax is ether lmr400 or 600 (not imp ) so naturally i'd use typically N connectors how much do i lose if I screw in a right angle adapter? My comment would be on the right angle N connectors. They vary dramatically. My area of interest is 1296MHz EME where any loss before the Feedhorn LNA shows up easily. I have an HP network analyzer and qualified a number of right angle N's. In general the adapter with a square block at the elbow were fine- under -0.03 dB. The gradual bend (called a sweep in plumbing terms I believe) had unacceptable return loss and much higher loss (sorry, no figures there). Dale W4OP |
#3
![]() |
|||
|
|||
![]()
On Sat, 30 Sep 2006 13:31:09 GMT, ml wrote:
hi I was wanting to dispel some myths about connector losses Hi Myles, They are largely myths. The true fact of the matter is in quality of construction and selection of materials. However, even there with a dedicated connection that is wrapped against the environment, a cheap materials connector will work as well (still, it must have good construction). lose going from a DIN to an N via a adapter?? That's a new one on me. There are a lot of DIN standards. some say the loss is actually neg some say it's going to add up and the insertion loss could easily go over 1/2 db i dunno Negatives add up to bigger negatives. The point of negatives is in application. You can say a connector is specified at -0.1dB or that it has 0.1dB loss - same thing. To say it has -0.1dB loss is something of an anachronism, but it is often encountered. exactly how good/bad is it? Same dependencies I've already mentioned. You probably couldn't measure it without sophisticated tools. and where can u get some good low loss adapters (i know of ampenol) I bought some unknowns at a flea market and they had great loss to which in that case i attribute to just poor quality I would then have to ask: How do you know they had "great loss?" 1dB loss at the connection point would be as hot as a Christmas tree lightbulb for 100W passing through it. 73's Richard Clark, KB7QHC |
#4
![]() |
|||
|
|||
![]()
In article t3vTg.1268$753.976@trnddc05,
"Dale Parfitt" wrote: "ml" wrote in message ... hi I was wanting to dispel some myths about connector losses lets assume my worst case freq 450mhz LOW /week singal work lets assume my worst coax is ether lmr400 or 600 (not imp ) so naturally i'd use typically N connectors how much do i lose if I screw in a right angle adapter? My comment would be on the right angle N connectors. They vary dramatically. My area of interest is 1296MHz EME where any loss before the Feedhorn LNA shows up easily. I have an HP network analyzer and qualified a number of right angle N's. In general the adapter with a square block at the elbow were fine- under -0.03 dB. The gradual bend (called a sweep in plumbing terms I believe) had unacceptable return loss and much higher loss (sorry, no figures there). Dale W4OP thanks rich and dale appreciate the help! rich i new the connector was bad cause i noticed less power on my meter swapped it out, got a few lemons ![]() dale: wow i always wondered about those elebow square designs , not sure what you ment by the 'gradual' bend ones i've seen the 'standard' right angle connectors but werent' 'gentle' they were 90 hard bends is this what you ment? or did you ment if you simply made a gentle arc in the coax vs using a rt angle connector tht a good connector rt angle adapter was better i'd like to put a few adapters both F/F and rt angles on but didn't want to do it if it would kill me loss wise thanks |
#5
![]() |
|||
|
|||
![]() "ml" wrote in message ... In article t3vTg.1268$753.976@trnddc05, "Dale Parfitt" wrote: "ml" wrote in message ... hi I was wanting to dispel some myths about connector losses lets assume my worst case freq 450mhz LOW /week singal work lets assume my worst coax is ether lmr400 or 600 (not imp ) so naturally i'd use typically N connectors how much do i lose if I screw in a right angle adapter? My comment would be on the right angle N connectors. They vary dramatically. My area of interest is 1296MHz EME where any loss before the Feedhorn LNA shows up easily. I have an HP network analyzer and qualified a number of right angle N's. In general the adapter with a square block at the elbow were fine- under -0.03 dB. The gradual bend (called a sweep in plumbing terms I believe) had unacceptable return loss and much higher loss (sorry, no figures there). Dale W4OP thanks rich and dale appreciate the help! rich i new the connector was bad cause i noticed less power on my meter swapped it out, got a few lemons ![]() dale: wow i always wondered about those elebow square designs , not sure what you ment by the 'gradual' bend ones i've seen the 'standard' right angle connectors but werent' 'gentle' they were 90 hard bends is this what you ment? or did you ment if you simply made a gentle arc in the coax vs using a rt angle connector tht a good connector rt angle adapter was better i'd like to put a few adapters both F/F and rt angles on but didn't want to do it if it would kill me loss wise thanks Both are 90 degree elbows- from my measurements the ones that have a square block of metal at the elbow were fine. The ones that looked like a 90 degree plumbing sweep had bad return loss. This may vary from mfg to mfg, but Al Ward W5LUA who has had experience up through 24GHz agrees. Perhaps I'll get time and inclination to mill one of the sweep styles open and see what's up. Dale W4OP |
#6
![]() |
|||
|
|||
![]() "ml" wrote in message ... hi I was wanting to dispel some myths about connector losses lets assume my worst case freq 450mhz LOW /week singal work lets assume my worst coax is ether lmr400 or 600 (not imp ) so naturally i'd use typically N connectors how much do i lose if I screw in a right angle adapter? in general at the base of a radio and same question say i want to join to lengths of coax and use a small stubby f/f N connector adapter ?? lose going from a DIN to an N via a adapter?? at radio and 'inline' joining 2 coax lengths some say the loss is actually neg some say it's going to add up and the insertion loss could easily go over 1/2 db i dunno I can help a little, just not at 450 MHz. In the 1970's I had the TV system on an aircraft carrier for maintenance. One slow day at sea, I tested the connector-loss stories. I took the longest piece of RG-59 I had (about 60' or so) and measured the loss around 60 MHz, Channel 3, the freq of my test generator. Next, I joined about ten pieces of RG-59 together to make the same length and repeated the measurement. I was surprised at my result: only about 1 dB more loss. Certainly nothing like the mythical 1 dB per connector figure that had been bandied about. Plus, crimped-on F-59 connectors have nothing to recommend them, compared to N-type connectors we use for UHF hamming. I did not have any right-angle F-connectors to test then. I have some now and I have modulators I can tune to UHF to source a stable signal. Maybe I'll run some more tests. |
#7
![]() |
|||
|
|||
![]()
Both are 90 degree elbows- from my measurements the ones that have a
square block of metal at the elbow were fine. The ones that looked like a 90 degree plumbing sweep had bad return loss. This may vary from mfg to mfg, but Al Ward W5LUA who has had experience up through 24GHz agrees. Perhaps I'll get time and inclination to mill one of the sweep styles open and see what's up. Dale W4OP This is a very strange result, the non 90 degree elbow ones, normally referred to as "swept radius" are intended to reduce the step discontinuities that the a 90 elbow type introduce. They are usually used at microwave frequencies where these discontinuities are more apparent. 73 Jeff |
#8
![]() |
|||
|
|||
![]()
In article 3eFTg.217$pS3.30@trnddc01,
"Dale Parfitt" wrote: "ml" wrote in message ... In article t3vTg.1268$753.976@trnddc05, "Dale Parfitt" wrote: "ml" wrote in message ... hi I was wanting to dispel some myths about connector losses lets assume my worst case freq 450mhz LOW /week singal work lets assume my worst coax is ether lmr400 or 600 (not imp ) so naturally i'd use typically N connectors how much do i lose if I screw in a right angle adapter? My comment would be on the right angle N connectors. They vary dramatically. My area of interest is 1296MHz EME where any loss before the Feedhorn LNA shows up easily. I have an HP network analyzer and qualified a number of right angle N's. In general the adapter with a square block at the elbow were fine- under -0.03 dB. The gradual bend (called a sweep in plumbing terms I believe) had unacceptable return loss and much higher loss (sorry, no figures there). Dale W4OP thanks rich and dale appreciate the help! rich i new the connector was bad cause i noticed less power on my meter swapped it out, got a few lemons ![]() dale: wow i always wondered about those elebow square designs , not sure what you ment by the 'gradual' bend ones i've seen the 'standard' right angle connectors but werent' 'gentle' they were 90 hard bends is this what you ment? or did you ment if you simply made a gentle arc in the coax vs using a rt angle connector tht a good connector rt angle adapter was better i'd like to put a few adapters both F/F and rt angles on but didn't want to do it if it would kill me loss wise thanks Both are 90 degree elbows- from my measurements the ones that have a square block of metal at the elbow were fine. The ones that looked like a 90 degree plumbing sweep had bad return loss. This may vary from mfg to mfg, but Al Ward W5LUA who has had experience up through 24GHz agrees. Perhaps I'll get time and inclination to mill one of the sweep styles open and see what's up. Dale W4OP that would be a very interesting experiment I guess i could hack saw open a regular 90 elbow rt angle but i thinkk i know what i would find and guess why they wouldn't work well could be wrong i have no test gear.... but i couldn't open the 'square' one it's not easy to hacksaw the one i have has a 'screw' at the square elbow but its cosmetic it won't 'openup' i really should find someone w/some sort of test rig and take some N--pl259 and etc adapters as well as some 90 adapters and do a experiment if i win the lotto i'd buy a rack of test gear (only a ham nerd would do that) thanks very much |
#9
![]() |
|||
|
|||
![]()
In article , "Jeff"
wrote: Both are 90 degree elbows- from my measurements the ones that have a square block of metal at the elbow were fine. The ones that looked like a 90 degree plumbing sweep had bad return loss. This may vary from mfg to mfg, but Al Ward W5LUA who has had experience up through 24GHz agrees. Perhaps I'll get time and inclination to mill one of the sweep styles open and see what's up. Dale W4OP This is a very strange result, the non 90 degree elbow ones, normally referred to as "swept radius" are intended to reduce the step discontinuities that the a 90 elbow type introduce. They are usually used at microwave frequencies where these discontinuities are more apparent. 73 Jeff yeah now that i had a chance to check some manuf spec's seems the losses they post for the regular rt angles looking like 2 pipe pieces mitered and the 'square' ones seem to have same loss .1 etc 11gig and are less ten bucks the swep ones i saw were rated to 18gig wow and like 150bucks loss and swr were about the same but from the very high end atten was best obv i don't have any first hand exp so i am not disagreeing i know when i've had the chance to test connectors in the past sometimes you did get some really dissapointing results m |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Inverted ground plane antenna: compared with normal GP and low dipole. | Antenna | |||
Ranger II 8 prong plug | Boatanchors | |||
Additional Line Losses Due to SWR | Antenna | |||
FS: Andrew 1/2" Superflex Connectors - 'N' Female | Swap | |||
Losses in PI-filter output | Antenna |