John Passaneau January 22nd 04 09:13 PM

In a 1:1 current balun, you would want the Z of the line in balun to be the
same as the transmission line i.e. 50 ohms not some Z in the middle. If it
is different it will do an impedance transformation of the load Z based on
the Z of the line in the balun, its length and frequency. In a 4:1 current
balun the Z should be about 100 ohms. I don't know if zip cord or what ever
you call it makes a 50 ohm open wire line. I think the spacing is to large.
I know that #14 enameled wire close spaced does make a 50 ohm line. Anyway
the difference in loss between #18 wire and RG-400 due to IR drop in the
length of wire in a balun is too small to worry about.


John Passaneau, W3JXP
Penn State University



"Reg Edwards" wrote in message
...
Reg, is that superior to coax wound on the same toroid?
I use RG-400 teflon coax for my baluns.
--
73, Cecil
http://www.qsl.net/w5dxp

============================

Just compare the coax inner conductor diameter with the 18-gauge wire of

the
zip-cord. Conductor resistance is inversely proportional to wire

diameter.

Furthermore, the transition from 50-ohm to open-wire line is less abrupt.
In theory, the impedance of the line wound on the transformer should be
intermediate between coax Zo and open-wire Zo.

On the other hand, the difference in loss due to either effect is hardly
detectable. The length of line involned is too small to make much
difference. I shouldn't bother changing the design.

I can't imagine how the coax got in there in the first place.
---
Reg, G4FGQ





Reg Edwards January 22nd 04 11:58 PM


Anyway
the difference in loss between #18 wire and RG-400 due to IR drop in the
length of wire in a balun is too small to worry about.

John Passaneau, W3JXP
Penn State University


=========================

Just like I said !

But a 1:1 choke balun has an indeterminate transformation ratio.



Dan Richardson January 23rd 04 12:21 AM

On Thu, 22 Jan 2004 10:43:15 -0600, Cecil Moore
wrote:

I use RG-400 teflon coax for my baluns.


I've done that too, however, the other day I was made aware of
teflon's problems with cold flow. You might want to look into that.

Danny, K6MHE




[email protected] January 23rd 04 12:45 AM

On Thu, 22 Jan 2004 15:30:52 +0000 (UTC), "Reg Edwards"
wrote:

Figure-of-eight . . . .

Two circles stuck together. Outline of plastic insulation surrounding a
pair of close-spaced wires.

Zip-cord ?
---
Reg


Apparently because when you separate the two at the thin part
at one end, you can just zip it apart easily as far as needed.


John Passaneau January 23rd 04 02:43 PM

A 1:1 choke balun made out of coax "chokes" off current flowing on the
outside of shield, it has no effect on what is happing inside the coax
between the inside of the shield and the center conductor. If you made a
choke balun wound on a toroid or with beads with 2 foot of 75 ohm coax and
used it on an antenna with a Z of 50 ohms at 28Mhz. That 2 foot of 75 ohm
coax would transform the 50 ohms to 59.4+j21.3 ohms at the output end of
your balun. If this is a problem it's up to the user to decide but I
wouldn't like it. The same effect would happen if the balun was made with a
parallel conductor line be it "zip cord" or enameled wire. If the Z of the
line in the choke balun doesn't match the Z of the feed line it will cause
an impedance transformation that will with vary with frequency. Of course if
one is only using the balun at 7Mhz or lower it will not be as noticeable as
it is at 28MHz.

--
John Passaneau, W3JXP
Penn State University


"Reg Edwards" wrote in message
...

Anyway
the difference in loss between #18 wire and RG-400 due to IR drop in the
length of wire in a balun is too small to worry about.

John Passaneau, W3JXP
Penn State University


=========================

Just like I said !

But a 1:1 choke balun has an indeterminate transformation ratio.





Reg Edwards January 23rd 04 05:37 PM

When connecting a 50-ohm circuit to a 600-ohm line via a choke balun it
makes no difference what the impedance of the short length of line forming
the choke might be.

For practical purposes the severe mismatch is due entirely to the difference
between 50 and 600 ohms.

One must avoid suffering from delusions of accuracy.
---
Reg



John Passaneau January 26th 04 04:26 PM

That's true but sometime we use current baluns in 50 ohm systems and one
should be aware of what happens to the Z when the line in the balun is some
random impedance.
I've done some tests on various types of baluns looking at balanced to
unbalanced conversion verses frequency and losses and I like 3 to 4"
diameter toroids with a mu of 100 to 200 wound with Teflon coax. Most of my
antennas are close to 50 ohm and I don't need any unwanted impedance
transformations.


--
John Passaneau W3JXP
State College Pa

This mail is a natural product. The slight variations in spelling and
grammar enhance its individual character and beauty and in no way are to
be considered flaws or defects.


"Reg Edwards" wrote in message
...
When connecting a 50-ohm circuit to a 600-ohm line via a choke balun it
makes no difference what the impedance of the short length of line

forming
the choke might be.

For practical purposes the severe mismatch is due entirely to the

difference
between 50 and 600 ohms.

One must avoid suffering from delusions of accuracy.
---
Reg





Reg Edwards January 30th 04 12:03 AM

wrote in message
...
On Thu, 22 Jan 2004 15:30:52 +0000 (UTC), "Reg Edwards"
wrote:

Figure-of-eight . . . .

Two circles stuck together. Outline of plastic insulation surrounding a
pair of close-spaced wires.

Zip-cord ?
---
Reg


Apparently because when you separate the two at the thin part
at one end, you can just zip it apart easily as far as needed.

========================

There are two varieties. One lays down flat on a flat surface. The other
has a twist, a lay, in it.

Only the first should be used for baluns.

If either is described as 'zip-cord' then there is ambiguity. Which is why I
described describe the cord used for baluns as 'figure of eight'. But I
suppose an ambiguity still remains.
---
Reg.