I'm not sure how many times it's worthwhile to keep repeating this, but
I guess I'll give it another couple of tries before giving up. Richard Harrison wrote: Roy Lewallen, W7EL wrote: "If you`ll read what I`ve written, you`ll hopefully see that my only point of contention is with your claim that waves reflect from a "virtual short". They do not." Seems to me they do. If you are lucky enough to have a copy of Terman`s 1955 opus, we can reason together. Sorry, I'm not. All I have is a 1947 Third Edition of _Radio Engineering_. I'm unfortunately stuck with having to think for myself. But I trust you to quote him accurately, and Terman is to be trusted. On page 91 is found Fig. 4-3 Vector (phasor) diagrams showing manner in which incident and reflected waves combined to produce a voltage distribution on the transmission line. I'm sure they're correct, and similar diagrams can be found in many of my other texts. At an open circuit, the voltage phasors are in-phase. Yes. And the current phasors are out of phase. E2, the reflected phasor, rotates clockwise as it travels back toward the source. E1, the incident phasor, rotates counter-clockwise as we look back toward the source. Yes. These of course follows from the mathematical analysis of transmission lines, found in many texts, and with which I'm very familiar. Looking 1/4-wavelength back from the open-circuit, E2 and E1, each having rotated 90-degrees, but in opposite directions, are now 180-degrees out-of-phase. On page 92, Fig. 4-4 shows the current, which summed to zero at the open circuit, has risen to its maximum value at 1/4-wavelength back from the open-circuit while the voltage dropped to its minimum, nearly zero, maybe close enough to declare a "virtual short-circuit", 1/4-wavelength back from the open-circuit. Yes, this is universally known. What`s a short-circuit? Little voltage and much current. Well, at a short circuit you'll find zero volts and any current. You'll also find this at other places which aren't short circuits, such as where multiple voltage waves add to zero and at the summing junction of a perfect op amp. These aren't short circuits, but they are points of zero voltage. Saying they are all the same is like saying that because you find water in a creek, any place you find water must be a creek. What sort of logic is that? What`s the difference between a physical short and the virtual short? Nothing except the shunting conductor. Well, yes. For one thing, waves won't reflect from a virtual short. They will, from a real short. Another difference is that a real short will prevent any waves from proceeding beyond it; they pass right through a virtual short. Good thing, too, or you wouldn't get any power to your load. Another is behavior at other frequencies and with other waveshapes. Walt has mentioned another, that a virtual short acts like a real short only in one direction, even when all the other conditions for similarity are met. Is there current flowing at the open-circuit end of the 1/4-wave line segment? No, the open-circuit won`t support current. Correct, of course. If a high-impedance generator of the same frequency were connected to the virtual short point on the line, would it also be shorted? Yes. Where? At the virtual short, not the open-circuit at the end of the line. Well, yes and no. When you first hook it to the virtual short, it won't be shorted -- it'll see just the Z0 of the cable. Only when its output reaches the end of the stub, reflects back, and adds to the forward wave will it be short circuited. So it's the open end of the line which is essential to creating the apparent short at the generator. Now let us, as you say, reason together. You're pointing out some similarities between a virtual short and a real one, and giving that as evidence that waves reflect from a virtual short. So consider a point on a 50 ohm line at which the forward and reverse waves add to a V/I of, say, 10 ohms, purely resistive to keep it simple. If you connect a generator (of the correct frequency) at that point, it will see 10 ohms after things settle down to steady state, just like your generator saw a short circuit at the "virtual short" in steady state. So can we conclude that a traveling wave will partially reflect when it encounters the 10 ohm point? The effective or "virtual" reflection coefficient can be calculated as -2/3, from which the reflected wave can be calculated. And, in fact, if we assume that such a reflection takes place, we can calculate the magnitude and phase of the resulting wave and, sure enough, there it will really be. But if the wave does really reflect from this "virtual discontinuity", we might have a problem. That point is a ways away from the "virtual short" point (check your Terman diagram if you don't follow), so we have a partial reflection occurring at this point as well as the full reflection from the "virtual short". In fact, unless the line is matched, we'll have reflections from every point along the line, or at best everywhere except an infinitesimally short spot every half wavelength! What a mess! Does Terman describe this problem in his book? A diagram, perhaps, showing the infinite number of partial reflections taking place all along the line? No? Well, then, maybe it takes a perfect "virtual short" to get a reflection, and even a tiny, tiny imperfection will prevent it. So that would mean that you'd get no reflection at all from a "virtual almost-short" on even a very slightly lossy line, right? The whole idea goes to pot when you add even a tiny amount of loss? Or is a little loss ok? Then we get a full reflection from a good or pretty good "virtual short", but nothing if it gets too far from perfection. Do me a favor and check your Terman for an equation or graph which shows just where this abrupt transition point is (that is, at what "virtual resistance" the reflection ceases), and why it exists. Help me out here with my reasoning. Roy Lewallen, W7EL |
Analyzing Stub Matching with Reflection Coefficients
Roy Lewallen wrote:
Richard Harrison wrote: If the virtual short were replaced with a real short, would anything change? Not a thing except the line voltage distribution diagram would lose its final 1/4-wavelength. Don't you consider it a significant difference that no voltage, current, or power would reach the load? :-) :-) That's what I asked when you said the virtual load on a transmitter could be replaced with a lumped circuit "without changing anything". -- 73, Cecil http://www.w5dxp.com |
Analyzing Stub Matching with Reflection Coefficients
Roy Lewallen wrote:
It's imperative to constantly be aware of the range over which those models are valid, and alert to any situation which might make the model invalid. Roy, if your model prohibits interaction of coherent waves, it is seriously flawed. -- 73, Cecil http://www.w5dxp.com |
Analyzing Stub Matching with Reflection Coefficients
Richard Harrison wrote:
Roy Lewallen, W7EL wrote: "If you`ll read what I`ve written, you`ll hopefully see that my only point of contention is with your claim that waves reflect from a "virtual short". They do not." Seems to me they do. I wonder if we can agree that if there is no physical impedance discontinuity, there can be no reflections? For instance, given a piece of 50 ohm open-ended coax with a driving source: source-----50 ohm coax-----+---1/4WL 50 ohm coax--open There is a virtual short at point '+' and that virtual short exists at a point where there is no physical impedance discontinuity. Can we agree that the forward wave is unaffected by that virtual short? Can we agree that the reflected wave is unaffected by that virtual short? After all, there is absolutely nothing there that can physically disrupt any waves. Or given one wavelength of coax being driven by a signal generator equipped with a circulator load. SGCL---1/4 WL---x---1/4WL---y---1/4WL---x---1/4WL---open There are obviously reflections at the open. Are there any reflections at the virtual open at 'y'? Are there any reflections at the virtual shorts at 'x'? I would submit that in the above example, the *only* reflections in the entire system are happening at the open end of of the coax and that the virtual shorts and opens are themselves effects and not the cause of anything (except maybe arguments) :-) -- 73, Cecil http://www.w5dxp.com |
Analyzing Stub Matching with Reflection Coefficients
Roy Lewallen wrote:
"Don`t you consider it a significant difference that no voltage, current, or power would reach the load?" No, because the example`s load is a perfect open-circuit despite Richard Clark`s disdain for good insulators. From the shorting point all the way back to the generator, the voltage distribution is unchanged, real short or virtual short. (I did not say unchanging.) Best regards, Richard Harrison, KB5WZI |
Analyzing Stub Matching with Reflection Coefficients
On Sun, 15 Apr 2007 19:23:56 +1000, Alan Peake wrote:
Walter Maxwell wrote: . . We have thus proved that the virtual short circuit established at the stub point is actually performing as a real short circuit. . . Walt, W2DU It is interesting to look at a single short pulse propagating along the TL. At the stub point, the pulse must encounter a discontinuity in impedance and therefore there will be a reflection. This can been seen on a TDR. So there is a real reflection from a stub regardless of whether or not it is a virtual short. Alan VK2ADB I thank you for that, Alan, because, to continue, when the pulse is replaced with a sine wave, there is also a reflection from the stub. And when going still further, since the stub presents a susceptance equal to the line susceptance of the opposite sign at the stub point, some of the sine wave continues along the line and reaches the mismatched termination, which also produces a real reflection. When the stub is placed at the proper place on the line relative to the SWR (mismatch), the phase of the waves (voltage and current) reflected from the load are opposite, respectively, to those of the waves reflected from the stub. The sum of the voltage waves then yield a resultant reflection coefficient of 180° and the sum of the current waves yield a resultant of 0°, establishing a short circuit to both sets of reflected waves, but an open circuit to the source waves. For people who understand that fields (voltage and current) radiating from two vertical radiators that are of the same magnitude and of opposite sign result in a null in their radiation pattern in a particular direction must also understand that for the null to be established there must also be interaction, or interference, or summing between the fields to cause the travel to cease in the null direction. These people also understand that energy that was traveling in the null direction has been re-directed in another direction, raising the level of the energy in that direction from the original level. IMHO, these people can't have it both ways. If the fields interact, or interfere in space, such as in those radiated from two radiators, then coherent fields traveling in a transmission line must also interact, interfere, or sum. This is the concept on which I'm basing my impedance matching analogy using the summation of reflection coefficients. Walt |
Analyzing Stub Matching with Reflection Coefficients
Walter Maxwell wrote:
... then coherent fields traveling in a transmission line must also interact, interfere, or sum. There is no doubt that Roy is absolutely wrong when he asserts that coherent EM waves do not interact. Every time we tune our antenna tuners to zero reflected energy, we are causing EM waves to interact following the rules of *linear* interference. All those waves, inductors, and capacitors within the antenna tuner are operating within a linear environment. If they weren't, we would generate lots of harmonics. Seems to me, the only valid point of argument is whether a purely virtual impedance is a cause or an effect. -- 73, Cecil http://www.w5dxp.com |
Analyzing Stub Matching with Reflection Coefficients
Cecil, W5DXP wrote:
"I wonder if we can agree that if there is no physical impedance discontinuity, there can be no reflection?" Terman says on page 118 of his 1955 opus: "When a wave traveling along a transmission line encounters an isolated discontinuity, it is partially reflected; i.e., while a portion of the wave continues to travel down the line, another portion of the wave is reflected backwards." On page 119 Terman says: "A traveling wave passing through such a section (a tapered transmission line to gradually and continuously change its impedance from one value to another) will have its ratio of voltage to current transformed in accordance with the ratio of the characteristic impedances involved." Abrupt changes in impedance are discontinuities which produce reflections. These are secondary energy sources. Total reflection produced the wave distribution diagrammed in Fig. 4-3 on page 91, from an open-circuit on the line. I see that a virtual short-circuit results 1/4-wave back from the open circuit and the "short" is repeated 1/2-wave back from the first virtual short. Through all the virtual shorts and opens, Terman shows the incident and reflected waves progressing unimpeded. I believe that if a generator is connected through 1/4-wave of transmission line to a real short, 360-degrees of phase rotation presents the generator with a voltage which is almost of the same phase and magnitude as the generator`s output. Almost no current flows either into the short or back into the generator. It is similar to connecting nearly identical transformer windings in parallel. Hybrid ring isolators are also constructed of 1/4-wave transmission line sections, and whether a port accepts or rejects energy results from voltage distributions at the ports, I think. Best regards, Richard Harrison, KB5WZI |
Analyzing Stub Matching with Reflection Coefficients
Richard Harrison wrote:
Through all the virtual shorts and opens, Terman shows the incident and reflected waves progressing unimpeded. Suggesting that a virtual short or virtual open, by itself, doesn't cause reflections which is what I think others are trying to say. Reflections associated with virtual shorts and virtual opens always occur with some extra ingredients, like physical impedance discontinuities, the very existence of which makes one wonder if they might somehow be associated with the reflections. Reflections always occur at physical impedance discontinuities. -- 73, Cecil http://www.w5dxp.com |
Analyzing Stub Matching with Reflection Coefficients
On Apr 14, 9:31 pm, Cecil Moore wrote:
Roy Lewallen wrote: K7ITM wrote: . . . It's a useful visualization tool and design aid; it's a poor analysis tool at best. At worst, it will lull you into building something that just won't work, wasting time and resources. In my opinion, the potential harm can be much worse. If it causes you to buy into the notion that traveling waves interact in a linear medium, that opens the door to a whole universe of invalid conclusions. Here is how Hecht described interference in "Optics": "... interference corresponds to the *interaction* of two or more lightwaves yielding a resultant irradiance that deviates from the sum of the component irradiances." If traveling waves cannot interact in a linear medium, why does Hecht say they do indeed interact? It is exactly that kind of misleading terminology that has caused his text to fall out of favor among many physics faculty. To deny the body of laws of physics regarding EM waves from the field of optics is an example of extreme ignorance. You really aren't qualified to speak on behalf of the field of optics, Cecil. You aren't quaified to speak on behalf of Eugene Hecht either, for that matter. However, I think Dr. Hecht is still around so perhaps you can persuade him to back you up. Be sure to ask him what he thinks about the 4th mechanism of reflection. ac6xg |