K7ITM wrote:
On Nov 17, 4:03 pm, Cecil Moore wrote: The waves are launched by the external reflection from a Z0-match and the internal reflection from the load. So the waves are going opposite directions along the line?? No, all reflections travel toward the source and therefore, are traveling in the same direction. Their Poynting vectors are all toward the source. Given the following Z0-match impedance discontinuity in a transmission line with the source to the left and the load to the right: Z0-match ------Z01---+---Z02------ Pfor1-- Pfor2-- --Pref1=0 --Pref2 The power reflection coefficient is rho^2 = [(Z02-Z01)/(Z02+Z01)]^2 Pref1 is a combination of two reflected waves 1. P1 = Pfor1(rho^2) "the external reflection from the Z0-match" 2. P2 = Pref2(1-rho^2) "the internal reflection from the load" Pref1 = P1 + P2 + 2*SQRT(P1*P2)cos(A) Pref1 equals zero at a Z0-match so P1+P2 and A=180 deg. -- 73, Cecil http://www.w5dxp.com |