Richard Harrison December 24th 07 10:05 AM

Standing-Wave Current vs Traveling-Wave Current
 
Cecil, W5DXP wrote:
However the VARS in the standing wave require energy which can be
converted to watts---."

VARS is an acronym for Volt Amps Reactive.
Apparent power can include real power and VARS. I would think that VARS
all have volts and amps in quadrature (at 90 degrees). If so, power is
VI cos theta. WI cos 90 degrees = VI (0)= 0, thus the power in VARS is
0.

Roy Lewallen December 24th 07 11:02 AM

Standing-Wave Current vs Traveling-Wave Current
 
Richard Harrison wrote:
Roy Lewallen, W7EL wrote:
"As any text can tell you, the value of Z (ratio of V to I) varies along
a line which has a reflected waves (i.e., has a standing wave)."

Not exactly, maybe the apparent Z. Uniform line is assumed and it has a
Zo determined only by line structure. Zo is identical for a signal
traveling in either direction. However, a directional coupler must be
used to measure voltage and current traveling in one direction while
ignoring voltage and current traveling in the opposite direction. A Bird
wattmeter uses a directional coupler.


I stand by my statement that Z (the ratio of V to I) varies along a line
which has reflected waves.

Voltage to current ratio on a line with reflections and standing waves
is of little practical value except for determinimg whether the capacity
of the line is exceeded or nearly so.


It's of essential use in the design of stub matching, impedance
transformation, and a host of other transmission line applications. A
Smith chart is a tool which shows this impedance, so the impedance
(voltage to current ratio) is of practical value in any application for
which the Smith chart is used.

. . .


Roy Lewallen, W7EL

Richard Harrison December 24th 07 11:21 AM

Standing-Wave Current vs Traveling-Wave Current
 
Roy Lewallen, W7EL wrote:
"Certainly, the total V and I are in quadrature if the line is
terminated by an open, short, or purely reactive load. But not in any
other case."

Something else is at work. The reflection reverses direction of the wave
producing a 180-degree phase shift in either voltage or current, but not
both, if there is a reflection. Because the waves are traveling at the
sane speed in approaching each other, they produce a phase reversal in a
distance of only 90-degrees instead of 180-degrees. This places the
waves in quadrature to stay. Terman shows the vector diagrams of
incident and reflected waves combined to produce a voltage distribution
on an almost lossless transmission line (Zo=R) for an open circuit case
and for a resistive load case where the load is Zo in Fig. 4-3 on
page 91 of his 1955 opus. Indeed, the angle between the incident and
reflected voltages is 90-degrees in either case.

In Fig. 4-4 on page 92, Terman shows voltage and current distributions
produced on low-loss transmission lines by different load impedances and
in every case volts and amps are in quadrature.

Best regards, Richard Harrison, KB5WZI





Richard Harrison December 24th 07 11:43 AM

Standing-Wave Current vs Traveling-Wave Current
 
Owen Duffy wrote:
"If that is the meaning, then the situation you describe of 90-degree
phase difference between E and I is rather specific, it can only occur
with a distortionless line AND a load that is (s/c OR o/c OR purely
reactive).

No. Walter is exactly right, and don`t drag any distortionless line into
the discussion. That is a device for audio circuits. For RF, you only
need a low-loss (Zo = R) transmission line.

Best regards, Richard Harrison, KB5WZI


Dave December 24th 07 11:49 AM

Standing-Wave Current vs Traveling-Wave Current
 

"Yuri Blanarovich" wrote in message
...

"Dave" wrote in message
news:UTAbj.1170$OH6.803@trndny03...

"Yuri Blanarovich" wrote in message
...

"Dave" wrote in message
news:mozbj.844$si6.691@trndny08...

"Yuri Blanarovich" wrote in message
...
So you are trying to say that there is standing wave voltage but no
standing wave current and therefore no power associated with
current???

i am saying that there is standing wave voltage, and standing wave
current, but there is no physical sense in multiplying them to
calculate a power. hence the concept of standing power waves is
meaningless.


K3BU found out that when he put 800W into the antenna, the bottom of
the coil started to fry the heatshrink tubing, demonstrating more
power to be dissipated at the bottom of the coil, proportional to the
higher current there, creating more heat and "frying power" (RxI2).
This is in perfect

right R*I^2 makes perfect sense. you are talking about ONLY the
current standing wave which makes perfectly good sense. and the R*I^2
losses associated with it make perfect sense. BUT, resistive losses
ARE NOT a result of power in the standing wave, they are resistive
lossed resulting from the current. remember the initial assumptions of
my analysis, a LOSSLESS line, hence there are not resistive losses. If
this requirement is changed then you can start to talk about resistive
heating at current maximums and all the havoc that can cause.

They seem to be real current and voltage, current heats up resistance,
voltage lights up the neons and power is consumed, portion is
radiated. The larger the current containing portion, the better
antenna efficiency.
Where am I wrong?

again on the voltage, it is exactly analogous to the current above.
voltage waves capacitively coupled to a neon bulb are losses and not
covered in my statements. But again note, that type of measurement is
measuring the peak voltage of the voltage standing wave, and any power
dissipated is sampled from that wave and is not a measure of power in
the standing wave.

I have a hard time to swallow statement that there is no power in
standing wave, when I SAW standing wave's current fry my precious coil
and tip burned off with spectacular corona Elmo's fire due to standing
wave voltage at the tip.

YOU HAVE IT RIGHT! the standing wave current causes heating. the
standing wave voltage causes corona. but neither one represents POWER
in the standing waves.


So we have better than perpetual motion case - we can cause heating
without consuming power. I better get patent for this before Artsie gets
it! There must be some equilibrium somewhere.

...like, there is standing wave current, there standing wave voltage,
but no standing wave and no power in it?

Richard, wake up your english majorettes and snort it out :-)


remember the relationship that must apply within the coax. and can be
extended to antennas, though it gets real messy taking into account the
radiated part and the change in capacitance and inductance along the
length of the radiating elements.

P=V^2/Z0=I^2*Z0

now remember that you only have to look at one or the other and at all
times the relationship in each wave must obey V=I*Z0.

Now consider the infamous shorted coax. at the shorted end the voltage
standing wave is always ZERO, by your logic the power would always be
zero at that point, but how can that be?? conversly, at a point where
the current standing wave is always zero there can be no power in the
standing wave, but at that point the voltage is a maximum so would say
the power was a maximum... an obvious contradiction.


I know one thing, when standing wave current is high, I get loses in the
resistance, wires heating up - power being used.
When standing wave voltage is high, I get dielectric loses, insulation
heats up and melts - power being used, ergo there is a power in standing
wave and is demonstrated by certain magnitude of current and voltage at
particular distance and P = U x I. I don't know what you are feeding
your standing wave antennas, but I am pumping power into them and some
IS radiated, some lost in the resistive or dielectric loses.

73 Yuri



you are SO CLOSE... open your eyes, turn off your preconceived notions
and read what i wrote again slowly and carefully.

FIRST remember the assumption was a LOSSLESS line so there are no
dielectric or resistive losses. But this is only useful because it makes
it easier to see that the power given by V*I in the standing waves
doesn't make sense.

YOU ARE CORRECT when you say that the R*I^2 loss is REAL... and YOU ARE
CORRECT when you say the V^2/R loss in dielectric is REAL.

Where you lose it is that the V*I for the standing waves is not
correct... this is because V and I are related to each other and you
can't apply superposition to a non-linear relationship. If you think you
have a way to do it then please take the given conditions of a lossless
transmission line, shorted at the end, in sinusoidal steady state, and
write the equation for power in the standing wave at 1/4 and 1/2 a
wavelength from the shorted end of the line.


So let me get this straight:
I describe real antenna situation, which is a standing wave circuit, with
real heating of the coil, which is consuming power demonstrably
proportional to the amount of standing wave current.
You are not answering rest of my argument.
You bring in lossless transmission line to argue that there can not be
power and no standing waves.
I still don't get it.

73 Yuri


ok, last try.. YOU ARE RIGHT!!! "consuming power demonstrably proportional
to the amount of standing wave current". LISTEN, YOU ARE RIGHT!!! the loss
in your coil is proportional to the square of the standing wave CURRENT. as
long as you keep saying that you are RIGHT. now repeat after me... the loss
in your coil is proportional to the square of the standing wave CURRENT.
emphasize CURRENT every time. DO NOT start talking about POWER in the
standing wave, then you will be wrong. Use the CURRENT young Yuri, Use the
CURRENT... forget the POWER of the standing wave.



Richard Harrison December 24th 07 11:56 AM

Standing-Wave Current vs Traveling-Wave Current
 
Cecil, W5DXP wrote:
"Therefore, A standing wave is not an EM wave - it is something else, by
definition."

Cecil hit the nail on its head. A standing wave is an interference
display of two waves of the same frequency traveling in opposite
directions.

Best regards, Richard Harrison, KB5WZI


Roy Lewallen December 24th 07 12:35 PM

Standing-Wave Current vs Traveling-Wave Current
 
Richard Harrison wrote:
Roy Lewallen, W7EL wrote:
"Certainly, the total V and I are in quadrature if the line is
terminated by an open, short, or purely reactive load. But not in any
other case."

Something else is at work. The reflection reverses direction of the wave
producing a 180-degree phase shift in either voltage or current, but not
both, if there is a reflection.


Yes.

Because the waves are traveling at the
sane speed in approaching each other, they produce a phase reversal in a
distance of only 90-degrees instead of 180-degrees. This places the
waves in quadrature to stay.


?? Which waves? Forward voltage and reverse current? Forward and reverse
voltage?

Terman shows the vector diagrams of
incident and reflected waves combined to produce a voltage distribution
on an almost lossless transmission line (Zo=R) for an open circuit case
and for a resistive load case where the load is Zo in Fig. 4-3 on
page 91 of his 1955 opus. Indeed, the angle between the incident and
reflected voltages is 90-degrees in either case.


Please look carefully at those diagrams. The horizontal axis is the
distance along the line. The diagrams are showing the relationship
between voltage and current envelopes as a function of position. The
graphs aren't showing the time phase of V and I, which is the matter
under discussion.

In Fig. 4-4 on page 92, Terman shows voltage and current distributions
produced on low-loss transmission lines by different load impedances and
in every case volts and amps are in quadrature.


I don't have that diagram in my 1947 Third Edition, but I'm sure that if
you'll study the diagram and accompanying text you'll find that it's
also a graph of peak amplitude vs position, not V or I as a function of
time.

Let me pose a very simple problem. Suppose you have a quarter wavelength
of 50 ohm transmission line terminated in 25 ohms and driven with a 100
volt RMS sine wave source. Consider the phase of the voltage source to
be the reference of zero phase angle.

1. What is the current at the line input? [Answer: 1 ampere, at 0 degree
phase]
2. What is the ratio of V to I at the line input? [Answer: 100 at an
angle of zero divided by 1 at an angle of zero = 100 + j0 ohms]
3. How do you resolve this with the graphs in Terman and your
explanation of the voltage and current being in quadrature everywhere
along the line?

Feel free to repeat this with any other line length. I'll wait very
patiently for the length which produces V and I in quadrature at the
input. A very interesting result of that would be that no power would be
consumed from the source, so if any reaches the load then we've created
power.

I'd be glad to post the equation relating Z (the ratio of V to I) at the
line input or any point along the line to the load and characteristic
impedances. But I'm afraid it would be wasted effort, since there's a
great reluctance here to actually work an equation or understand its
meaning. But good and accurate graphs of what Richard has claimed the
Terman graphs show (but don't) can be found in the _ARRL Antenna Book_.
In the 20th and 21st Editions, the graphs are Fig. 12 on p. 24-9. In
other editions, they're probably also Fig. 12 in the Transmission Lines
chapter. In the graphs, the angle between the I and E vectors is the
relative phase angle between the two, and also the angle of the
impedance of the point where the vectors are shown.

Roy Lewallen, W7EL

Denny December 24th 07 01:23 PM

Standing-Wave Current vs Traveling-Wave Current
 
On *The voltage is
indeed real, as i have said. *you can measure the 'standing' wave voltage,
that has been known for a long time... but the effects are NOT due to power
in standing waves.-


OK, that was the least word infested post I can find...

1. A standing wave is not 'standing' in time... It phase rotates at
the same rate as the excitation frequency...
If the phase is rotating then V and I are changing - else Feynman is
rotating in his grave...
To do so requires the surface electrons at that point on the line to
oscillate back and forth or whatever the heck surface electrons do at
rf frequency... To excite these electrons from one energy state to
another requires power/energy/joules/whatever-you-want-to-call-it...

2. It is real because I can measure it with a volt meter and I can
extract power from it with a lamp, simultaneously..

Also: it will perforate the insulating jacket on the line if the power
level is high enough... I used to maintain a herd of 100KW RF
generators, and they would blow a hole through the side of a quarter
inch thick copper bar in an instant when the load failed in my
youthfull ignorance, I thought it was the standing wave RATIO that
blew the line, silly me ...



Try this thought... A Tesla coil (automobile spark coil) with no load
on the output is all standing wave voltage and no current - so
according to some has no power... Touch your finger to it...
Also try: If an open ended line has 100.000 volts of DC on it, the
standing wave DC contains no power because the current is zero?

And, for whoever it was accused me of bashing someone - reread my
post, carefully.... I absolutely do not bash or flame anyone...

cheers ... denny

Cecil Moore[_2_] December 24th 07 01:44 PM

Standing-Wave Current vs Traveling-Wave Current
 
Roy Lewallen wrote:
I'm surprised that standing waves seem so hard for people to understand.
They're simply a spatial pattern formed by the interference between
forward and reflected waves or, if you prefer, from the solution to a
general transmission line problem with boundary values applied. I'd hope
that even a brief look at a text would make it clear what standing waves
are, and what they are not.


Roy, if you would take a "brief look at a text", you
would know NOT to try to use standing wave current phase
to measure the delay through a 75m loading coil. At any
point in time, the standing wave current phase is essentially
the same value all up and down a 1/2WL dipole including
through any loading coils. Phase does NOT equate to delay
in a standing wave environment.
--
73, Cecil http://www.w5dxp.com

Keith Dysart[_2_] December 24th 07 01:44 PM

Standing-Wave Current vs Traveling-Wave Current
 
On Dec 24, 6:49*am, "Dave" wrote:
"Yuri Blanarovich" wrote in message

...







"Dave" wrote in message
news:UTAbj.1170$OH6.803@trndny03...


"Yuri Blanarovich" wrote in message
...


"Dave" wrote in message
news:mozbj.844$si6.691@trndny08...


"Yuri Blanarovich" wrote in message
...
So you are trying to say that there is standing wave voltage but no
standing wave current and therefore no power associated with
current???


i am saying that there is standing wave voltage, and standing wave
current, but there is no physical sense in multiplying them to
calculate a power. hence the concept of standing power waves is
meaningless.


K3BU found out that when he put 800W into the antenna, the bottom of
the coil started to fry the heatshrink tubing, demonstrating more
power to be dissipated at the bottom of the coil, proportional to the
higher current there, creating more heat and "frying power" (RxI2).
This is in perfect


right R*I^2 makes perfect sense. *you are talking about ONLY the
current standing wave which makes perfectly good sense. *and the R*I^2
losses associated with it make perfect sense. *BUT, resistive losses
ARE NOT a result of power in the standing wave, they are resistive
lossed resulting from the current. *remember the initial assumptions of
my analysis, a LOSSLESS line, hence there are not resistive losses. *If
this requirement is changed then you can start to talk about resistive
heating at current maximums and all the havoc that can cause.


They seem to be real current and voltage, current heats up resistance,
voltage lights up the neons and power is consumed, portion is
radiated. The larger the current containing portion, the better
antenna efficiency.
Where am I wrong?


again on the voltage, it is exactly analogous to the current above.
voltage waves capacitively coupled to a neon bulb are losses and not
covered in my statements. * But again note, that type of measurement is
measuring the peak voltage of the voltage standing wave, and any power
dissipated is sampled from that wave and is not a measure of power in
the standing wave.


I have a hard time to swallow statement that there is no power in
standing wave, when I SAW standing wave's current fry my precious coil
and tip burned off with spectacular corona Elmo's fire due to standing
wave voltage at the tip.


YOU HAVE IT RIGHT! *the standing wave current causes heating. *the
standing wave voltage causes corona. *but neither one represents POWER
in the standing waves.


So we have better than perpetual motion case - we can cause heating
without consuming power. I better get patent for this before Artsie gets
it! There must be some equilibrium somewhere.


...like, there is standing wave current, there standing wave voltage,
but no standing wave and no power in it?


Richard, wake up your english majorettes and snort it out :-)


remember the relationship that must apply within the coax. and can be
extended to antennas, though it gets real messy taking into account the
radiated part and the change in capacitance and inductance along the
length of the radiating elements.


P=V^2/Z0=I^2*Z0


now remember that you only have to look at one or the other and at all
times the relationship in each wave must obey V=I*Z0.


Now consider the infamous shorted coax. *at the shorted end the voltage
standing wave is always ZERO, by your logic the power would always be
zero at that point, but how can that be?? *conversly, at a point where
the current standing wave is always zero there can be no power in the
standing wave, but at that point the voltage is a maximum so would say
the power was a maximum... an obvious contradiction.


I know one thing, when standing wave current is high, I get loses in the
resistance, wires heating up - power being used.
When standing wave voltage is high, I get dielectric loses, insulation
heats up and melts - power being used, ergo there is a power in standing
wave and is demonstrated by certain magnitude of current and voltage at
particular distance and P = U x I. I don't know what you are feeding
your standing wave antennas, but I am pumping power into them and some
IS radiated, some lost in the resistive or dielectric loses.


73 *Yuri


you are SO CLOSE... open your eyes, turn off your preconceived notions
and read what i wrote again slowly and carefully.


FIRST remember the assumption was a LOSSLESS line so there are no
dielectric or resistive losses. *But this is only useful because it makes
it easier to see that the power given by V*I in the standing waves
doesn't make sense.


YOU ARE CORRECT when you say that the R*I^2 loss is REAL... and YOU ARE
CORRECT when you say the V^2/R loss in dielectric is REAL.


Where you lose it is that the V*I for the standing waves is not
correct... this is because V and I are related to each other and you
can't apply superposition to a non-linear relationship. *If you think you
have a way to do it then please take the given conditions of a lossless
transmission line, shorted at the end, in sinusoidal steady state, and
write the equation for power in the standing wave at 1/4 and 1/2 a
wavelength from the shorted end of the line.


So let me get this straight:
I describe real antenna situation, which is a standing wave circuit, with
real heating of the coil, which is consuming power demonstrably
proportional to the amount of standing wave current.
You are not answering rest of my argument.
You bring in lossless transmission line to argue that there can not be
power and no standing waves.
I still don't get it.


73 Yuri


ok, last try.. *YOU ARE RIGHT!!! *"consuming power demonstrably proportional
to the amount of standing wave current". *LISTEN, YOU ARE RIGHT!!! *the loss
in your coil is proportional to the square of the standing wave CURRENT. *as
long as you keep saying that you are RIGHT. *now repeat after me... the loss
in your coil is proportional to the square of the standing wave CURRENT.
emphasize CURRENT every time. *DO NOT start talking about POWER in the
standing wave, then you will be wrong. *Use the CURRENT young Yuri, Use the
CURRENT... forget the POWER of the standing wave.- Hide quoted text -


It seems to me that a bit more precision in the use of
language might help. So, strictly:

It is consuming power proportional to the square of
the RMS current at that point on the line, and the
constant of proportionality is the resistance of
the line over the length of interest.

When an author writes "standing wave current", do
they always mean the RMS current at a point on the
line? Or do they mean the envelope of the RMS
current at each point along the line? Or the
envelope of the peak current at each point? Or the
RMS value of the spatially distributed peak currents
along the line? Or? What is THE standing wave
current? No wonder there is so much dispute.

And could someone who likes to write "standing
wave power" (Yuri perhaps?) please provide an
unambiguous definition? It does not have to be
the "right" definition, or agreed by all, just
any definition which is unambiguous.

...Keith