On Feb 20, 12:22*am, Cecil Moore wrote:
Keith Dysart wrote:
Steven Best's article does have an equation of similar form:


PFTOTAL = P1 + P2 + 2 * sqrt(P1) * sqrt(P2) * cos(theta)


Starting with superposition of two voltages, he derived an
equation based on powers for computing the total power.


The derivation proves the equation to be valid.
The redundancy inside a transmission line of Z0 characteristic
impedance means we don't have to deal with voltages at all


Not quite, since the angle 'theta' is the angle between the voltages,
is it not?

if
we know the length of the transmission line and the reflection
coefficient of the load. Pfor = Vfor^2/Z0 *Pref = Vref^2/Z0

Perhaps you could carry out the calculations for a slightly
different experiment. Use a 25 ohm source impedance and a
voltage oF 70.7 RMS.


Note you are cutting the source voltage and source resistance
in half while keeping the rest of the network the same. The
forward power cannot remain at 100w.


I am pretty sure that it is 100 W. See more below.

Forward and reverse power for the short circuited load will
still be 100 W, but only 200 W will be dissipated in the
source resistor. It is not obvious to me how to compute the
interference term for this case.


Nope, forward and reverse power will not still be 100w.
Forward and reverse power will be 50w. It will be
44.44w + 4.94w + 0.549w + 0.06w + ... = 50 watts
The source is now exhibiting a power reflection coefficient
of 0.3333^2 = 0.1111 so there is a multiple reflection
transient state before reaching steady-state.


I suggest that you forgot to use Steven Best's equation when
you added the powers. Consider just the first re-reflection
where 4.94 is added to 44.4.

Pftotal = 44.444444 + 4.938272 + 2 * sqrt(44.444444) * sqrt(4.938272)
* cos(0)
= 49.382716 + 9.599615
= 79.01 W

To verify, let us consider the voltages:

Original Vf is 66.666666 V (peak)
First re-reflection is -66.666666 V * -0.3333333 - 22.222222 V (peak)
giving a new Vf of 88.888888 V (peak)
which is 79.01 W into 50 ohms.

It does, indeed, converge to 100 W forward but you have to use the
proper equations when summing the powers of superposed voltages.
You can not just add them.

So forward and reverse powers each converge to 100 W and 200 W is
dissipated in the source resistor, which suggests that your
equation for computing dissipation in the source resistor is
incorrect.

To take the tedium out of these calculation you might like the
Excel spreadsheet at
http://keith.dysart.googlepages.com/...oad,reflection

...Keith
 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
"Food for thought: Forward and reverse power" comments Cecil Moore Antenna 17 July 1st 05 04:20 AM
Yaesu Ft920 power hooked up in reverse/reverse polarity k8vf Equipment 4 August 9th 03 09:16 AM
Yaesu Ft920 power hooked up in reverse/reverse polarity k8vf Equipment 0 August 7th 03 04:41 AM