Home |
Search |
Today's Posts |
#11
![]() |
|||
|
|||
![]()
On Thu, 3 Apr 2008 10:35:17 -0700 (PDT)
Keith Dysart wrote: On Apr 3, 9:47*am, Roger Sparks wrote: On Wed, 2 Apr 2008 06:33:46 -0700 (PDT) I am sorry Keith, but I still can not duplicate your work. *I wonder if the difference is in how we each apply the recharge voltage to the transmission line. I do not know. The spreadsheet that did the work is now available from this page: http://keith.dysart.googlepages.com/radio6 Perhaps with the extra detail, you can find the discrepancy. I redid my table showing the *power in the source and reflected waves.. *I now have the power to resistor Rs coming from voltage agreeing with the expected power calculated from current. * My sheet agrees with yours for the samples I checked. ...Keith I think that at 91 degrees, the sign of the returning wave should be positive, not negative. Thus, it should be +1.234v. My reasoning is that the voltage from the line side of the resistor adds to the voltage from the source side of the resistor, but in this case it takes a little longer to get around the loop. The 90 degrees is timing, the lead edge of the wave is not reversed by turning the corner at what we call the short. Another way of thinking about it is that if the transmission line was shorter, the added voltage to the resistor from the line side would arrive even earlier, and add. If the line were zero length, there would be no question but that the voltage would add. Lastly, your current peaks at 135 degrees, not 45 degrees, which should be the delay. It is interesting to notice that the current is delayed 45 degrees, but the voltage is delayed 90 degrees. It is as if the current does not take the entire trip around the loop, but the voltage does. The current apparently travels an average of half the distance around the loop. I know that the convention for calculating the reflection coefficient is to make it negative for a shorted transmission line. The negative sign makes sense because the voltages at the short cancel so we have a zero voltage across the short. That convention sure messes up our spread sheet calculations however. -- 73, Roger, W7WKB |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Now for the rest of the story! | General | |||
Now for the rest of the story! | Policy | |||
Now for the rest of the story! | General | |||
Now for the rest of the story! | Policy | |||
WTD: Paul Harvey Rest of the Story broadcasts from Sep 1 thru 6 | Broadcasting |