RadioBanter

RadioBanter (https://www.radiobanter.com/)
-   Antenna (https://www.radiobanter.com/antenna/)
-   -   SWR meter vs TLI (https://www.radiobanter.com/antenna/2286-swr-meter-vs-tli.html)

Roy Lewallen September 4th 04 08:02 PM

This has been explained many times, to no avail.

So instead of one of us explaining it yet again, I suggest that you do
the following experiment. It requires only a transmitter, one or two
dummy loads, an SWR meter, and no more than five minutes of your time.

1. Connect the transmitter to either a dummy load or an antenna through
the SWR meter and measure the SWR.

2. Connect the transmitter in parallel with a dummy load by using a tee
connector. Connect this parallel combination to the input of the SWR
meter, and the output of the SWR meter to the same load as before (dummy
load or antenna).

Do you see any change in the SWR?

If you don't, then something is wrong with your theory -- since the
source impedance is clearly different for the two measurements --, and
you should take the effort of resolving it with your recent observations.

Roy Lewallen, W7EL

Richard Fry wrote:
"Ian White, G3SEK"wrote:

Richard Fry wrote:

"Ian White, G3SEK wrote

The meter measures nothing that involves the source, except
the level of RF that it supplies. It does not respond in any way
whatever to the source impedance.

Not that I said it did in my part of the thread, but nevertheless the


above

statement is not strictly true. In the case where the source Z of the tx


PA

does not match its load Z (which is typical), power reflected from the


load

mismatch will at least partly be re-reflected from the PA -- which then
contributes to the power sensed by a "wattmeter" in the output path.


Sorry, that statement cannot be correct. It would mean that the
impedance you measure at the near end of a transmission line (terminated
by some arbitrary load at the far end) would depend on the internal
impedance of the device that's doing the measuring - and that is not
true, either in transmission-line theory or in the real world. It is a
function only of the line and the load. etc


____________

How, then, do you explain the "ghost image" that can occur* in analog(ue) TV
transmission systems arising from reflections at/near the antenna end of the
station's transmission line?

*with sufficient round-trip propagation time in the transmission line

RF



Roy Lewallen September 4th 04 08:06 PM

Ian White, G3SEK wrote:

Reg Edwards wrote:

For those who have forgotten how or have never measured SWR.


Hang on, Reg - didn't you spend your career working on VLF cables that
went under the ocean?


How did you keep the water out of the slotted cable? And how far did you
have to swim between Vmax and Vmin?

Roy Lewallen, W7EL

Roy Lewallen September 4th 04 08:15 PM

Let me suggest an additional exercise for Richard and anyone else that
believes that source impedance affects the SWR.

Those of us who believe otherwise can easily calculate the SWR which
will exist on a line, and the SWR that will be read by an SWR meter at
any point in a system, by knowing simply the line length and impedance
and the load impedance. We don't require knowledge of the source
impedance. The equations we use can be found in numerous places, and
these have been used for over a century to design working systems.

You must use other equations to predict SWR -- equations which include
source impedance. It would be very interesting to see those equations.
Your equations and ours will predict different results from the simple
test I proposed. So if you'll show us the equation you use to calculate
SWR which includes source impedance, it'll be easy to see whether it's
correct or not.

Roy Lewallen, W7EL

Cecil Moore September 4th 04 08:15 PM

Richard Clark wrote:
I see you have yet to respond to this very matter attended to quite at
length by Chipman.


I have recently realized that those terms in Chipman's equations are
interference terms. EM wave interference is not understood very well
by RF people although it is understood very well by optics people.

For instance, the superposing of two coherent voltages in a Z0
environment is well known.

Vtot = V1 + V2 (assume V1 and V2 are in phase)

Squaring both sides and dividing by Z0 yields the power.

Vtot^2/Z0 = (V1+V2)^2/Z0

Vtot^2/Z0 = V1^2/Z0 + V2^2/Z0 + (2*V1*V2)/Z0

Note that the first term to the right of the equals sign is the
power associated with the V1 wave and the second term is the
power associated with the V2 wave. The third term is the
interference term. If V1 and V2 are in phase, the third term
will be constructive interference.

If the phase angle between V1 and V2 is less than 90 degrees,
the interference is constructive, i.e. cos(theta) is positive.

If V1 and F2 were 180 degrees out of phase, the interference
would be destructive.

If the phase angle between V1 and V2 is between 90 degrees and
180 degrees, the interference is destructive, i.e. cos(theta)
is negative.

Interference is the reason for those extra terms in Chipman's
equations. It always happens when the sum of two voltages
are squared to get the power.

Reference: _Optics_, by Hecht.
--
73, Cecil http://www.qsl.net/w5dxp


-----= Posted via Newsfeeds.Com, Uncensored Usenet News =-----
http://www.newsfeeds.com - The #1 Newsgroup Service in the World!
-----== Over 100,000 Newsgroups - 19 Different Servers! =-----

Richard Fry September 4th 04 08:46 PM

"Roy Lewallen" wrote
Let me suggest an additional exercise for Richard and anyone else that
believes that source impedance affects the SWR. (etc)

____________________

Just one sec, please. I didn't say that the true SWR connected to the tx
output connector was affected. I said that the RF power measured at the
sample point(s) in the transmitter can be affected by the source and load
impedances of the tx, for the reasons stated.

The true load SWR does not change under these conditions, but it cannot then
be determined by such a meter. Attempting to do so will yield some value,
but it will be wrong.

RF



Tam/WB2TT September 4th 04 09:40 PM


"Walter Maxwell" wrote in message
...
On Fri, 3 Sep 2004 17:16:48 -0300, "Another Voice"

wrote:

**** Post for FREE via your newsreader at post.usenet.com ****

"Richard Harrison"
Just how short can a transmission line be
and still enforce its Zo?


The whole thing is perfectly clear if one imagines applying a step

function
(rising edge) to any short, even VERY short, length of transmission line.
The current in the short line will be equal to V/Zo - at least until the
reflections (if any) start arriving back at the input. If the line

happen
to be terminated with Zo, then no reflections and I=V/Zo is the steady
state.

The only issue of shortness is that a very short line means very short

time
until the reflections arrive.

The step function makes things a lot easier to understand than RF. It
'enforces' the distinction between the transient period and steady state.

IMO, the length of the line is irrelevant when using a device such as the

Bruene
bridge or a Bird 43. Each of those instruments are designed or adjusted to
indicate the forward or reflected power, based on three things: 1) ratio

of the
foward and reflected voltages, the voltage reflection coefficient 2) the

scale
numbered from 0 to 1, where 0 indicates the reflection is zero, and 1

equals
total reflection, but the significant point is that a 3:1 mismatch gives a
reflection coefficient of 0.5, which then means that the half-scale

reading of
0.5 indicates the 3:1 mismatch, or a 3:1 SWR, and 3) the device is so

designed
or adjusted so that the voltage ratios indicate the correct value because

it's
inherent characteristic impedance, Zo, is 50 ohms.

Thus, no transmission line is necessary. For example, the device can be
connected directly to the antenna terminals, or any other device you

desire to
determine the mismatch, and power it directly from the signal source--no
transmission line is needed on either port for the device to indicate the

degree
of mismatch.

Walt, W2DU


Walt,

I hope people are listening to what you are saying. I built up a Bruene
meter in SWCAD using 0% tolerance components and other ideal parts. Works
exactly like Bird claims their meter does, except that the error only
depends on the PC floating point arithmetic. Transmission line or not makes
no difference. BTW, it is kind of neat to see the directional coupler
properties, by driving the two sides with different signals, and then being
able to separate them.

Tam/WB2TT



Roy Lewallen September 4th 04 10:44 PM

Sorry, I must have misinterpreted your earlier posting.

But we seem to now have a "true SWR" as opposed to some other kind of
SWR. And "true SWR connected to the tx output" doesn't have any meaning
at all to me. I also have no idea of what "sample points within the
transmitter" might be. So let me explain what I (and virtually all
published literature) mean by SWR.

If we connect a transmitter to an SWR meter, and then to a long piece of
lossless cable with the same Z0 as the SWR meter, and finally to a load,
the SWR meter reading will be the same as the VSWR on the cable, i.e.,
the ratio of maximum to minimum voltages on the line. This ratio of
voltages is, by definition, the VSWR -- which equals the ISWR, and is
often referred to simply as SWR.

If we measure or calculate the impedance seen looking into the line,
then disconnect the line from the SWR meter and replace it and the load
with lumped elements of the same impedance, the SWR meter reading won't
change(*).

Now, I can calculate the what the SWR meter reading will be under this
condition also. In both cases, the source impedance won't affect the SWR
meter reading, the positions or relative magnitudes of the maximum and
minimum voltages on the line, or the voltage or current within the SWR
meter line section. (This last condition assumes that the net power
delivered by the source stays the same; otherwise, the ratio of voltage
to current, and their phase angles, stay constant, regardless of the
power delivered.)

I have no idea how all this relates to your "true SWR". But do you agree
with what I've said above? If not, I'll describe a couple of simple
experiments which will test it against any alternative view you might
propose.

(*) We can also replace them with a load at the end of a line of
different Z0. As long as we choose the load Z and the line length to
make the impedance seen at the line input the same as before, the SWR
meter will read the same as before -- even though it no longer equals
the actual VSWR on the transmission line. The SWR meter is really
indicating the impedance seen looking into the line, not in this case
the actual line VSWR. (That's the essence of Reg's objection to the SWR
meter designation. Of course, if I connect my ammeter across a resistor,
it's not measuring the current through the resistor, either.)

Roy Lewallen, W7EL


Richard Fry wrote:
"Roy Lewallen" wrote

Let me suggest an additional exercise for Richard and anyone else that
believes that source impedance affects the SWR. (etc)


____________________

Just one sec, please. I didn't say that the true SWR connected to the tx
output connector was affected. I said that the RF power measured at the
sample point(s) in the transmitter can be affected by the source and load
impedances of the tx, for the reasons stated.

The true load SWR does not change under these conditions, but it cannot then
be determined by such a meter. Attempting to do so will yield some value,
but it will be wrong.

RF



Reg Edwards September 4th 04 10:50 PM

Ian White, G3SEK wrote:

Reg Edwards wrote:

For those who have forgotten how or have never measured SWR.


Hang on, Reg - didn't you spend your career working on VLF cables that
went under the ocean?


How did you keep the water out of the slotted cable? And how far did you
have to swim between Vmax and Vmin?

Roy Lewallen, W7EL

===============================

Water can be kept out of slotted cables by the ship's radio operator who
never has anything else to do. We used to toss him overboard with a ladle
and pump. On occasions we used the ship's doctor when he wasn't propping up
the bar boozing duty-free scotch.

Didn't have to swim anywhere. The propagation velocity is so low at ELF in
sea water it is necessary only to sit on a stool in a diving suit and wait
for the max's and min's to pass by.
---
Reg.



Richard Fry September 4th 04 11:35 PM

"Roy Lewallen" wrote

But we seem to now have a "true SWR" as opposed to
some other kind of SWR. And "true SWR connected to
the tx output" doesn't have any meaning at all to me.


My "true SWR" term is used is an attempt to differentiate between the SWR of
the antenna system, and the inaccuracies associated with trying to measure
it with devices that cannot isolate the incident power in the system from
internal reflections of that power. For the conditions and reasoning
outlined in my earlier posts in this thread, and even though the system SWR
is a constant -- the normal SWR meter used in/with an operating transmitter
working into a mismatched load won't have the ability to give strictly
accurate measurement of that SWR. That is all I'm saying.

I also have no idea of what "sample points within the
transmitter" might be.


In broadcast gear, these are the directional couplers whose pickup probes
are inserted transversely into the coaxial line between the harmonic filter
output and the tx output connector. I haven't been a licensed ham for over
40 years (when I went into the broadcast field), but I expect some ham txs
might have the same setup. Otherwise it could be a Model 43 or the like
inserted between the output connector of the ham tx and the transmission
line to the antenna.

I hope this is understandable now.

RF



Ian White, G3SEK September 4th 04 11:54 PM

Richard Fry wrote:

Ian White wrote:
The so-called SWR meter is a steady-state instrument, so it always makes
sense to use that quicker, easier way of thinking. Since you're the one
who chooses to think of this particular situation in terms of multiple
reflections, any difficulties you encounter are entirely yours.


This reads to me as though you know they are there, but choose to
ignore them...?


Oh no, quite the opposite - but since these difficulties are entirely of
your own making, you get to do the work :-)

If you ever see a conflict between two different theories that explain
the same observed facts, then there's an error somewhere.


We agree on the subject of conflict resolution, but apparently not on
the location of the error.

Thank you for the more detailed explanation below... which, sure enough,
revealed where the error is.

If the multiple-reflection theory is extrapolated to infinite time, so
that it calculates results for the steady state, it *must* give identical
results to the steady-state theory. But whenever the steady-state
theory can be used, it will always get you there much more quickly.


This is true only to the extent that all the power ever generated by
the transmitter eventually either is radiated by the antenna or is
dissipated by losses somewhere.

That is exactly true in the steady state.

For simplicity, let's assume a tx with a source impedance of zero ohms
feeds a lossless transmission line of uniform impedance throughout its
length to a mismatch at the far end. The mismatch reflects a
percentage of the incident power back down the line to the tx, and
continues to do so as long as the transmitter generates power. The tx
will re-reflect the reflected power back to the far end -- in this case
all of the reflected power it ever sees, in fact. To this easily-seen,
real-world reality you agreed above ("Yes, that is a true observation, ...").

The re-reflections combine with the power generated by the tx at that
instant to create a vector sum at the sample point used by the meter.


There's the error: you can't "combine... power" in that way. You can
only create vector sums of voltage; and separately, vector sums of
current.

To make the multiple-reflection theory work correctly, you have to do
two separate vector sums at output port of the transmitter. First you
add all the voltage vectors: the 1st (original) forward, the 1st
reflected, the 2nd forward (re-reflected), 2nd reflected... and so on,
summed to infinity to give the correct result for the steady state.
Then you do the exactly same for all the forward and reflected current
vectors.

In order to account for reflection from the transmitter, you have to
assume some value of source impedance. Any value will do, for reasons
we'll see in a moment.

Now you can calculate two things: the vector ratio, which is the complex
impedance that the transmitter sees as a load; and the scalar product,
which is the power the transmitter can deliver into that load.

If you vary the source impedance of the transmitter, it will change all
the summed voltage vectors and all the summed current vectors - but each
voltage term in the sum will be changed by exactly the same factor as
its corresponding current term. Certainly the product (the output
power) will change, but the ratio (the load impedance) will not.

So, when correctly worked out, the load impedance is *not* a function of
the transmitter output impedance or the output power. Likewise, the
indication of the SWR meter is not a function of either the transmitter
output impedance or the output power - this last one being a well-known
fact.



--
73 from Ian G3SEK 'In Practice' columnist for RadCom (RSGB)
http://www.ifwtech.co.uk/g3sek

Richard Fry September 4th 04 11:57 PM

"Richard Clark" wrote
To date in this matter, I have yet to see any concrete value of source
Z offered from those of the NOT 50 Ohms camp. Further, I have yet to
see any of them offer any experimental confirmation of their assertion

________________

Please see the following. In the quote there, note the text starting "The
transmitter's output source impedance must be low...", and the following
sentences.

+ + +

Below is a quote from a paper titled "A Study of RF Intermodulation Between
FM Broadcast Transmitters Sharing Filterplexed or Co-located Antenna
Systems," by Geoffrey Mendenhall. Mendenhall is a registered professional
engineer, and now a VP for Harris Broadcast Division in Mason, OH. He is
responsible for the engineering research and design of the entire broadcast
transmitter product line for Harris: AM, FM & TV. Harris is the world's
largest supplier of broadcast transmitters.

This paper and quote has to be read here with some interpretation, because
it is an analysis of what happens when an in-band signal from one
transmitter is coupled into another transmitter when their antennas are
close together and/or when adequate filtering of the external signal is not
provided. But it is strictly applicable also for single tx and antenna
systems, where an antenna mismatch produces reflections back toward the
transmitter. In this case the "interfering signal" is not external, but a
reflection of the incident power of that tx.

QUOTE: Output return loss is a measure of the interfering signal that is
coupled into the output circuit versus the amount that is reflected back
from the output circuit without interacting with the non-linear device. To
understand this concept more clearly, we must remember that although the
output circuit of the transmitter is designed to work into a fifty ohm load,
the output source impedance of the transmitter is not fifty ohms. If the
source impedance were equal to the fifty ohm line impedance, half of the
transmitter's output power would be dissipated in its internal output source
impedance. The transmitter's output source impedance must be low compared
to the load impedance in order to achieve good efficiency. The transmitter
therefore looks like a voltage source driving a fifty ohm load. While the
transmission line is correctly terminated looking toward the antenna (high
return loss), the transmission line is greatly mismatched looking toward the
output circuit of the transmitter (low return loss). This means that power
coming out of the transmitter is completely absorbed by the load while
interfering signals fed into the transmitter are almost completely reflected
by the output circuit. END QUOTE

The transmitter topology in this study was a single PA tube operating Class
C. For these designs, an on-carrier return loss value of 2 dB or less is
rather common. At 2 dB the reflection coefficient is over 79%.

PAs comprised of multiple devices combined by balanced methods (e.g. 3dB
hybrids, Wilkinsons) can provide a source impedance closer to 50 ohms
(higher return loss). In these cases, power that is reflected off the load
and NOT re-reflected by the tx mostly is dissipated in resistive networks in
the PA combiner. However these networks do not provide a load for the
forward power from the tx, only for power reflected by the output
termination.

RF

Visit http://rfry.org for FM broadcast RF system papers.



Roy Lewallen September 5th 04 12:00 AM

Sorry, it still isn't clear.

Richard Fry wrote:
"Roy Lewallen" wrote

But we seem to now have a "true SWR" as opposed to
some other kind of SWR. And "true SWR connected to
the tx output" doesn't have any meaning at all to me.



My "true SWR" term is used is an attempt to differentiate between the SWR of
the antenna system, and the inaccuracies associated with trying to measure
it with devices that cannot isolate the incident power in the system from
internal reflections of that power. For the conditions and reasoning
outlined in my earlier posts in this thread, and even though the system SWR
is a constant -- the normal SWR meter used in/with an operating transmitter
working into a mismatched load won't have the ability to give strictly
accurate measurement of that SWR. That is all I'm saying.


What, then, is "system SWR"? How do you define it?


I also have no idea of what "sample points within the
transmitter" might be.



In broadcast gear, these are the directional couplers whose pickup probes
are inserted transversely into the coaxial line between the harmonic filter
output and the tx output connector. I haven't been a licensed ham for over
40 years (when I went into the broadcast field), but I expect some ham txs
might have the same setup. Otherwise it could be a Model 43 or the like
inserted between the output connector of the ham tx and the transmission
line to the antenna.


In your last posting, you said,

Just one sec, please. I didn't say that the true SWR connected to the
tx output connector was affected. I said that the RF power measured
at the sample point(s) in the transmitter can be affected by the
source and load impedances of the tx, for the reasons stated.


So replacing "sample point(s) in the transmitter" with "Model 43 or the
like inserted between the output connector of the ham tx and the
transmission line to the antenna", you've said that the RF power
measured by the (model 43) SWR meter can be affected by the source
impedance of the transmitter.

Obviously, if we have a voltage or current source of fixed value and
change the source impedance, the power delivered by the source changes,
and any means of measuring the power at the source, load, or in between
should show that change. That follows from elementary circuit theory,
and doesn't require any consideration or knowledge of transmission
lines, waves, or SWR. On the model 43, both the "forward" and "reverse"
powers will change, but by the same fraction. Perhaps that's what you
mean. But if you mean that the SWR reading or the ratio of "forward" to
"reverse" power changes as a result of changing the source impedance,
that's easily shown to be false by the simple experiment I proposed.

I hope this is understandable now.

Almost, but not quite.

Tam/WB2TT September 5th 04 12:50 AM


"Roy Lewallen" wrote in message
...
This has been explained many times, to no avail.

So instead of one of us explaining it yet again, I suggest that you do
the following experiment. It requires only a transmitter, one or two
dummy loads, an SWR meter, and no more than five minutes of your time.

1. Connect the transmitter to either a dummy load or an antenna through
the SWR meter and measure the SWR.

2. Connect the transmitter in parallel with a dummy load by using a tee
connector. Connect this parallel combination to the input of the SWR
meter, and the output of the SWR meter to the same load as before (dummy
load or antenna).


If you don't have 2 dummy loads, there is a simple alternative. Connect the
TX to the meter through a 1/4 wave section of 75 Ohm line. Unless the TX
output was 75 Ohms, the equivalent TX output impedance seen by the meter has
changed.

Tam/WB2TT

Do you see any change in the SWR?

If you don't, then something is wrong with your theory -- since the
source impedance is clearly different for the two measurements --, and
you should take the effort of resolving it with your recent observations.

Roy Lewallen, W7EL

Richard Fry wrote:
"Ian White, G3SEK"wrote:

Richard Fry wrote:

"Ian White, G3SEK wrote

The meter measures nothing that involves the source, except
the level of RF that it supplies. It does not respond in any way
whatever to the source impedance.

Not that I said it did in my part of the thread, but nevertheless the


above

statement is not strictly true. In the case where the source Z of the

tx

PA

does not match its load Z (which is typical), power reflected from the


load

mismatch will at least partly be re-reflected from the PA -- which then
contributes to the power sensed by a "wattmeter" in the output path.

Sorry, that statement cannot be correct. It would mean that the
impedance you measure at the near end of a transmission line (terminated
by some arbitrary load at the far end) would depend on the internal
impedance of the device that's doing the measuring - and that is not
true, either in transmission-line theory or in the real world. It is a
function only of the line and the load. etc


____________

How, then, do you explain the "ghost image" that can occur* in

analog(ue) TV
transmission systems arising from reflections at/near the antenna end of

the
station's transmission line?

*with sufficient round-trip propagation time in the transmission line

RF





Walter Maxwell September 5th 04 12:58 AM

On Sat, 4 Sep 2004 17:57:26 -0500, "Richard Fry" wrote:

"Richard Clark" wrote
To date in this matter, I have yet to see any concrete value of source
Z offered from those of the NOT 50 Ohms camp. Further, I have yet to
see any of them offer any experimental confirmation of their assertion

________________

Please see the following. In the quote there, note the text starting "The
transmitter's output source impedance must be low...", and the following
sentences.

+ + +

Below is a quote from a paper titled "A Study of RF Intermodulation Between
FM Broadcast Transmitters Sharing Filterplexed or Co-located Antenna
Systems," by Geoffrey Mendenhall. Mendenhall is a registered professional
engineer, and now a VP for Harris Broadcast Division in Mason, OH. He is
responsible for the engineering research and design of the entire broadcast
transmitter product line for Harris: AM, FM & TV. Harris is the world's
largest supplier of broadcast transmitters.

This paper and quote has to be read here with some interpretation, because
it is an analysis of what happens when an in-band signal from one
transmitter is coupled into another transmitter when their antennas are
close together and/or when adequate filtering of the external signal is not
provided. But it is strictly applicable also for single tx and antenna
systems, where an antenna mismatch produces reflections back toward the
transmitter. In this case the "interfering signal" is not external, but a
reflection of the incident power of that tx.


A critical point made in the quote below is evidence of a serious
misunderstanding concerning the relationship between the source impedance of the
tx and the load impedance.

QUOTE: Output return loss is a measure of the interfering signal that is
coupled into the output circuit versus the amount that is reflected back
from the output circuit without interacting with the non-linear device. To
understand this concept more clearly, we must remember that although the
output circuit of the transmitter is designed to work into a fifty ohm load,
the output source impedance of the transmitter is not fifty ohms. If the
source impedance were equal to the fifty ohm line impedance, half of the
transmitter's output power would be dissipated in its internal output source
impedance.


The last sentence in the paragraph above is incorrect. This shows that the
writer of the quote is in the unbelievably large group that still believes
incorrectly that half of the tx power would be lost if if it were conjugately
matched. But we all know that efficiencies greater than 80% is achieved by Class
C amps, and greater than 60% is achieved by Class B amps when the source
impedance of the tx is 50 ohms resistive and the load impedance is also 50 ohms
resistive.

I have made appropriate measurements in a professional RF laboratory that prove
this point. The data from these measurements and the procedure used is available
for downloading from my web site at http://home.iag.net/~w2du under the title
"On the Nature of the Source of Power in Class B and C Amplifiers." This piece
is Chapter 19 in Reflections II, and also appears in QEX,, May/Jun 2001.

Unfortunately, like the statement made in the 'quote' above, there are all too
many RF engineers who fail to appreciate the true relationship between the two
separate resistances in the amp, the resistance resulting in dissipation and the
resistance responsible for delivering the power to the load. I guarantee the
reader of the piece referenced above will come away with something to think
about.

The transmitter's output source impedance must be low compared
to the load impedance in order to achieve good efficiency. The transmitter
therefore looks like a voltage source driving a fifty ohm load. While the
transmission line is correctly terminated looking toward the antenna (high
return loss), the transmission line is greatly mismatched looking toward the
output circuit of the transmitter (low return loss). This means that power
coming out of the transmitter is completely absorbed by the load while
interfering signals fed into the transmitter are almost completely reflected
by the output circuit. END QUOTE

The transmitter topology in this study was a single PA tube operating Class
C. For these designs, an on-carrier return loss value of 2 dB or less is
rather common. At 2 dB the reflection coefficient is over 79%.

snip
RF

73,

Walt, W2DU


Wes Stewart September 5th 04 12:59 AM

On Sat, 4 Sep 2004 14:46:38 -0500, "Richard Fry"
wrote:

|"Roy Lewallen" wrote
| Let me suggest an additional exercise for Richard and anyone else that
| believes that source impedance affects the SWR. (etc)
|____________________
|
|Just one sec, please. I didn't say that the true SWR connected to the tx
|output connector was affected. I said that the RF power measured at the
|sample point(s) in the transmitter can be affected by the source and load
|impedances of the tx, for the reasons stated.

Not so fast yourself. You said, "The generic function of this meter is
to measure the degree of match between a source and a load."

There is no power mentioned in your statement. I, and others, stated
that your first statement was incorrect and since that time you have
been introducing prodigious amounts of verbiage in an attempt to
obfuscate and avoid the obvious error in your earlier statement.

Just slap your forehead and say, "Shucks, I blew it with that one" and
we can all forget about it. I do it all of the time.

|
|The true load SWR does not change under these conditions, but it cannot then
|be determined by such a meter. Attempting to do so will yield some value,
|but it will be wrong.

Oh please. If an SWR meter, direction bridge, TLI or whatever you
want to call it has decent directivity, i.e. the ability to discern
forward and reflected power, forward and reflected waves, reflection
coefficient, scattering parameters, or whatever you want to call them,
then the applied power is immaterial.

We are trying to measure a RATIO, not some absolute value of power.


Reg Edwards September 5th 04 02:09 AM


"Roy Lewallen" wrote

If we connect a transmitter to an SWR meter, and then to a long piece of
lossless cable with the same Z0 as the SWR meter, and finally to a load,
the SWR meter reading will be the same as the VSWR on the cable, i.e.,
the ratio of maximum to minimum voltages on the line.


=========================================

It is at this point where impressionable novices are led astray by old
wives, never again to return to logical thought on the subject.

They imagine that because the meter happens to indicate the swr on the line,
the meter is actually responding to the swr on it. Whereas the meter is
actually responding to the modulus of the reflection coefficient caused by
the line's input impedance regardless of what its Zo may be. The act of
making the line's Zo and the meter's resistance both equal to the
transmitter's designed-for load resistance, has put additional infomation
into the system. Cooking the books!

If there's an SWR to be indicated it is on a long line between meter and the
transmitter. In the absence of such a line the meter wastefully discards
half of the information it is presented with and indicates the modulus of
the reflection cofficient. A more appropriate name is TLI.
----
Reg, G4FGQ



Richard Clark September 5th 04 04:12 AM

On Sat, 4 Sep 2004 14:08:53 +0000 (UTC), "Reg Edwards"
wrote:

NOTE: In the above description and calculation there is no mention of Zo,
terminating impedance, source impedance, reflection coefficient, forward
power, reflected power, reflected volts, reflected current, Smith charts, or
conjugate matches. All these things are superflous to the determination. No
information other than the two voltage measurements is needed.


Hi All,

No mention merely means there is no offer of accuracy (not very
important, eh what?). These two measurements (repeated at intervals)
can reveal a SWR that varies along the length of the line like a snake
- UNLESS of course, you DO observe unmentionables like Load reflection
co-efficients and Source reflection co-efficients. As such, a
description of how not to measure SWR, but rather how to exhibit error
if you perchance have the misfortune of having a transmitter that is
unmatched to a 50 Ohm transmission system whose load is in fact
mismatched also.

Need I point out that if both ends are matched - what's the point in
measuring SWR? ;-)

73's
Richard Clark, KB7QHC

Ian Jackson September 5th 04 08:40 AM

In message , Reg Edwards
writes

"Roy Lewallen" wrote

If we connect a transmitter to an SWR meter, and then to a long piece of
lossless cable with the same Z0 as the SWR meter, and finally to a load,
the SWR meter reading will be the same as the VSWR on the cable, i.e.,
the ratio of maximum to minimum voltages on the line.


=========================================

It is at this point where impressionable novices are led astray by old
wives, never again to return to logical thought on the subject.

They imagine that because the meter happens to indicate the swr on the line,
the meter is actually responding to the swr on it. Whereas the meter is
actually responding to the modulus of the reflection coefficient caused by
the line's input impedance regardless of what its Zo may be. The act of
making the line's Zo and the meter's resistance both equal to the
transmitter's designed-for load resistance, has put additional infomation
into the system. Cooking the books!

If there's an SWR to be indicated it is on a long line between meter and the
transmitter. In the absence of such a line the meter wastefully discards
half of the information it is presented with and indicates the modulus of
the reflection cofficient. A more appropriate name is TLI.
----
Reg, G4FGQ



Would this help?

On the subject of whether the TX impedance affected the SWR reading, I
propose the following practical test:
Using standard CATV bits and pieces, connect up the following-
Signal source directional coupler #1 directional coupler #2 load.
DC#1 picks off the forward signal, DC#2 picks off the reverse.
Use a spectrum analyser to measure signal levels.
Beforehand check the DCs for go directivity, and chose a frequency where
it is best (at least 25dB). This will probably be around 20MHz.
With good load, measure forward and reverse signals.
Repeat with known load mismatch.
Screw up source impedance (eg add T-piece at source o/p, and
double-terminate).
Repeat the above.
Think about what the results mean.

Ian.



--


Richard Harrison September 5th 04 11:14 AM

Richard Fry quoted Geoffrey Mendenhall who is responsible for the entire
Harris broadcast transmitter line design as saying:
"If the source impedance were equal to the 50 ohm line impedance, half
the transmitter`s output would be dissipated in its internal output
source impedance."

Mendenhall is wrong.

A Class C amplifier`s "internal output source impedance" is largely
"dissipationless resistance" produced by the non-conduction time during
its RF cycle. A matched Class C amplifier typically produces
efficiencies exceeding 50% by a comfortable margin. That`s why they are
used despite their harmonic generating nonlinearity.

Best regards, Richard Harrison, KB5WZI




Richard Fry September 5th 04 11:17 AM

"Wes Stewart" wrote:
Oh please. If an SWR meter, direction bridge, TLI or whatever you
want to call it has decent directivity, i.e. the ability to discern
forward and reflected power, forward and reflected waves, reflection
coefficient, scattering parameters, or whatever you want to call them,
then the applied power is immaterial.

We are trying to measure a RATIO, not some absolute value of power.

_______________

However an SWR meter, direction(al) bridge, TLI or whatever you want to call
it has NO ability to discern between two waves traveling in the same
direction, unless their detectors are operating in the time domain -- which
normally they do not. That is the "feature" causing the anomalies I have
been writing about.

RF



Richard Harrison September 5th 04 11:58 AM

Richard Fry wrote:
"It doesn`t matter whether we state the result of measurement in units
of SWR, return loss, or as a reflection coefficient -- they all give the
same information -- ."

Correct. The units above are fungible. All are an expression of the
mismatch of a load to the Zo of the transmission line.

With a Bird wattmeter, the reflection coefficient (rho) is the sq. rt.
of the reflected power divided by the forward power.

SWR = 1+rho / 1-rho

Return loss in dB = 20 log (rho)

Return loss in dB = 10 log (Ref.Pwr./Fwd.Pwr.)

Rho = (ZL/Zo)-1 / (ZL/Zo)+1

None of the expressions above include the source Z, therefore it does
not apply.

Best regards, Richard Harrison, KB5WZI


Richard Fry September 5th 04 12:39 PM

"Roy Lewallen" wrote:
Sorry, it still isn't clear.

What, then, is "system SWR"? How do you define it?


System SWR is the net SWR of a component assembly present at its input
terminals. "Antenna system SWR" then is comprised of the net SWR of
everything in the RF path from the output of the SWR meter to and including
the antenna. In a transmitter, the antenna system begins electrically at
the output of the SWR meter -- physically close to the output connector of
the tx.

Obviously, if we have a voltage or current source of fixed value
and change the source impedance, the power delivered by the
source changes,


But the mechanism I've described considers the re-reflection by a mismatched
source of power not initially absorbed by a mismatched load -- not that a
change of source impedance changed the total power flowing out of the
source.

...both the "forward" and "reverse" powers
will change, but by the same fraction...


Agree. I'm not so sure that the Model 43 or equivalent methods used in/with
transmitters accurately preserves the power ratios under these conditions,
though.

RF



Reg Edwards September 5th 04 01:18 PM

What's a directional coupler?
What do they look like?
Don't bother answering those questions.

Why do the arguers, when caught in a tight corner, always escape to UHF for
help from directional couplers?

There are NO directional couplers at HF. They are as scarce as real swr
meters. So they cannot be used in futile attempts to explain what really
happens at HF.

You're next move will be to drag in scattering-matrices.
---
Reg ;o)



Brian Reay September 5th 04 01:41 PM


"Reg Edwards" wrote in message
...
What's a directional coupler?
What do they look like?
Don't bother answering those questions.

Why do the arguers, when caught in a tight corner, always escape to UHF

for
help from directional couplers?

There are NO directional couplers at HF.


So what is the element in my Bird Thruline then, and how does it work?

I'd dying to hear at what frequencies directional couplers suddenly begin to
"exist". A sudden change in the laws of Physics at some arbitary frequency
named by man.

(Most SWR meters I've seen use a directional coupler, by the way. Even the
cheap ones.)

I think we've got to the root of Reg's problem. Just like the last time he
raised this nonsense.

--
Brian Reay
www.g8osn.org.uk
www.amateurradiotraining.org.uk
FP#898



Richard Fry September 5th 04 01:49 PM

"Richard Clark" wrote
To date in this matter, I have yet to see any concrete value of source
Z offered from those of the NOT 50 Ohms camp. Further, I have yet to
see any of them offer any experimental confirmation of their assertion

Richard Fry wrote:
Below is a quote from a paper titled "A Study of RF Intermodulation

Between
FM Broadcast Transmitters Sharing Filterplexed or Co-located Antenna
Systems," by Geoffrey Mendenhall. (clip). Quoting Mendenhall, "...If the
source impedance were equal to the fifty ohm line impedance, half of the
transmitter's output power would be dissipated in its internal output

source
impedance..."

Walter Maxwell wrote
The last sentence in the paragraph above is incorrect. This shows that
the writer of the quote is in the unbelievably large group that still

believes
incorrectly that half of the tx power would be lost if if it were

conjugately
matched. But we all know that efficiencies greater than 80% is achieved
by Class C amps, and greater than 60% is achieved by Class B amps
when the source impedance of the tx is 50 ohms resistive and the load
impedance is also 50 ohms resistive.

_______________

To Walter Maxwell:

1. You may be interested in reading Mendenhall's complete paper, which I
will email to you. The lab measurements reported in it used two, operating,
high-power FM broadcast transmitters -- and support his statements about
amplifier source impedance and its consequences.

2. I will ask again, if transmitters have a 50 ohm source impedance, what
accounts for the fact that TV ghosts are produced by an antenna system
reflection having a sufficient delay time? Calculations and measured data
show that the energy that produced the ghost originated by re-reflection off
the TV transmitter output stage of far-end reflections in the antenna
system. If the tx source impedance was 50 ohms, it would absorb the far-end
reflection, which would be incapable of producing a ghost image.

Further, if the tx source impedance was 50 ohms, then the RF intermodulation
measured and reported in Mendenhall's paper -- and verified in real-world
installations by the radiated interference those IM products produced --
would not occur.

RF



Richard Harrison September 5th 04 01:58 PM

Reg, G4FGQ wrote:
"There are NO directional couplers at HF."

Behold the Bird wattmeter!

Why not call the SWR indicator a "mismatch meter"?

Best regards, Richard Harrison, KB5WZI


Richard Fry September 5th 04 02:05 PM

The meaning of this paragraph in my last post in this thread is more clearly
understood when two commas are added...

But the mechanism I've described considers the re-reflection,
by a mismatched source, of power not initially absorbed by a
mismatched load -- not that a change of source impedance
changed the total power flowing out of the source.




Ian Jackson September 5th 04 02:15 PM

In message , Reg Edwards
writes
What's a directional coupler?
What do they look like?
Don't bother answering those questions.

Why do the arguers, when caught in a tight corner, always escape to UHF for
help from directional couplers?

There are NO directional couplers at HF. They are as scarce as real swr
meters. So they cannot be used in futile attempts to explain what really
happens at HF.

You're next move will be to drag in scattering-matrices.
---
Reg ;o)



Reg, I thought that a DC was essentially any device which sampled some
of the RF signal travelling in one direction, and (if perfect) none of
the signal travelling in the other. Over the past 40 years, I have had
lots of dealings with them. I've even designed some which were bought in
their thousands (if not millions). Some of them seemed to work from
below 5MHz to over 870MHz (well, I THOUGHT they did, and so did the
people who bought them).

Where did I go wrong?

On the positive side, I never went as far as to claim that they would
measure SWR.

Ian.
--


Wes Stewart September 5th 04 03:35 PM

On Sun, 5 Sep 2004 12:18:09 +0000 (UTC), "Reg Edwards"
wrote:

|What's a directional coupler?
|What do they look like?
|Don't bother answering those questions.
|
|Why do the arguers, when caught in a tight corner, always escape to UHF for
|help from directional couplers?
|
|There are NO directional couplers at HF. They are as scarce as real swr
|meters. So they cannot be used in futile attempts to explain what really
|happens at HF.
|
|You're next move will be to drag in scattering-matrices.

Why not. I have used an HP3577 network analyzer with an S-parameter
test set that was specified to work over the frequency range of 100 Hz
to 200 Mhz.

I guess the guys at HP didn't realize that you can't do this.

Richard Clark September 5th 04 04:37 PM

On Sun, 5 Sep 2004 07:49:06 -0500, "Richard Fry"
wrote:

if transmitters have a 50 ohm source impedance,


Hi OM,

There you go again "IF." IF indeed!

It seems you find controversy where there is none. :-)

I would again suggest you read what I wrote, and point out what
exactly your contention is with IT.

73's
Richard Clark, KB7QHC

Richard Fry September 5th 04 04:44 PM

And another example in point:

From the input to a TV transmit antenna system, tx disconnected, I have
personally measured the far-end antenna system reflections of a 2T sin²
video pulse (0.25 µs H.A.D.) modulated onto a TV channel carrier, and
detected by a vestigial sideband demodulator tuned to that TV channel. A
high-directivity directional coupler at the input to the main line, a
display device, calibrated attenuators, and the time difference between the
incident and reflected pulse enable accurate measurement of the reflection
coefficient of the antenna system.

This was a common practice after a new antenna system installation to
measure and optimize the far-end match for the best quality radiated signal,
and was pioneered by RCA Broadcast Eqpt Div, my employer at the time. More
elegant means are used these days.

When this test shows a 5% pulse return 2 µs after the incident pulse time
(for example), then the same pulse passed through the tx also shows nearly
exactly the same reflection % and time separation -- assuming there is
enough RF delay in the system for the reflection to be resolved in the
demodulated waveform.

As the directional coupler driving the normal demodulator at the TV station
is looking at forward power only, it is clear that the reflection from the
far end of the antenna system has been re-reflected from the TV tx output
stage, and NOT absorbed by it in its "conjugate impedance."

RF



Richard Clark September 5th 04 04:57 PM

On Sun, 5 Sep 2004 05:14:46 -0500, (Richard
Harrison) wrote:

Mendenhall is wrong.


Hi Richard,

But this gets curiouser and curiouser (as Alice through the Looking
Glass would offer).

Cited as an example of the "NOT 50 Ohm" society (and one of its
leading proponents) we find that Geoff Mendenhall's notable
achievement in 1968 was building a 400W FM amplifier. Truly a
hands-on achievement. Now if we simply review the historical archive
and ask Geoff himself what the Z of his design was, we find by his own
hand:
RF Output Impedance: 50 Ohms

Let's see, no technical argument, and sources that are
self-contradicting. Whatchagonnado? Punt? :-)

73's
Richard Clark, KB7QHC

Richard Fry September 5th 04 05:05 PM

Richard Clark wrote
"Richard Fry" wrote:
if transmitters have a 50 ohm source impedance,


It seems you find controversy where there is none. :-)
I would again suggest you read what I wrote, and
point out what exactly your contention is with IT.

_________________

OK. Earlier you wrote, "To date in this matter, I have yet to see any
concrete value of source Z offered from those of the NOT 50 Ohms camp.
Further, I have yet to see any of them offer any experimental confirmation
of their assertion (made rather simple by the exhibition of uncertainty)."

Our controversy is illustrated by my posts with an opposite conclusion,
beginning last night and continuing this morning.

As for experimental evidence, I report some in my post here of a few minutes
ago about making refl coeff measurements of TV transmit antenna systems.

Mendenhall's paper also has experimental evidence of this. I will email it
to you.

I trust my contention is now clear to you.

RF



Richard Fry September 5th 04 05:14 PM

"Richard Clark" wrote
But this gets curiouser and curiouser (as Alice through the Looking
Glass would offer).

Cited as an example of the "NOT 50 Ohm" society (and one of its
leading proponents) we find that Geoff Mendenhall's notable
achievement in 1968 was building a 400W FM amplifier. Truly a
hands-on achievement. Now if we simply review the historical archive
and ask Geoff himself what the Z of his design was, we find by his own
hand:
RF Output Impedance: 50 Ohms

Let's see, no technical argument, and sources that are
self-contradicting. Whatchagonnado? Punt? :-)

73's
Richard Clark, KB7QHC




Richard Clark September 5th 04 05:21 PM

On Sun, 5 Sep 2004 11:05:24 -0500, "Richard Fry"
wrote:

I trust my contention is now clear to you.


Hi OM,

Actually no. Your reference, Mendenhall, specifically writes about
his design:
"It was necessary to determine the plate
load impedance (formula) = 1000 Ohms
where Emin min drop across the tube in saturation
I1 ac plate current.

"Since this Zp was to be coupled into a
Z output of 50 Ohm, a impedance transformation
of 20:1 was needed."

Fairly straightforward stuff there. Geoff's own notes are the model
of economy and directly to the nut of the issue. His notes are also
straight from old school first principles. As often happens, the more
elaborate the discussion of rather simple matters belies the inference
of hucksterism.

Seems like ALL my arguments, references, citations, data offered and
so on are congruent with Geoff's own description of amplifiers. I
certainly need no further testimony from him as I am perfectly capable
of finding his own work and offering it here. Thanx anyway, but no
thanx.

It would also serve you better to read more and write less, after all
I SPECIFICALLY mandated a discussion of transistor amateur amplifiers.
When I allowed this divergence to tubes, Mendenhall himself proved
that NOTHING changes in the physics of sources.

73's
Richard Clark, KB7QHC

Richard Fry September 5th 04 05:25 PM

"Richard Clark" wrote
Now if we simply review the historical archive
and ask Geoff himself what the Z of his design was,
we find by his own hand:
RF Output Impedance: 50 Ohms

Let's see, no technical argument, and sources that are
self-contradicting. Whatchagonnado? Punt? :-)

________________

You assume he refers to the source impedance of/at output of the amplifier.
More likely he is following convention and stating the load impedance that
the amplifier was designed to work into.

The source impedance of most transmitters is not published even today. If
it was, probably we wouldn't be having all of this confusion about it, and
its effects.

RF



Richard Harrison September 5th 04 05:49 PM

Brian Reay wrote:
"---dying to hear at what frequencies directional couplers suddenly
begin to exist."

It isn`t sudden.

They sure work at audio frequencies. In telephones, they are used to
prevent the user`s voice from overpowering the distant party`s voice in
the user`s ear. They are called hybrids.

Hybrids are also used to couple a 2-wire circuit which simultaneously
carries both directions of transmission with a 4-wire circuit consisting
of a transmit pair and a receive pair.

Best regards, Richard Harrison, KB5WZI


Richard Fry September 5th 04 05:51 PM

"Richard Clark" wrote
I SPECIFICALLY mandated a discussion of transistor
amateur amplifiers.

____________________

At least there appears to be an acknowledgement that some RF amplifiers do
not have a source impedance that is the conjugate of their load impedance.
So progress has been made.

RF



Richard Clark September 5th 04 06:05 PM

On Sun, 05 Sep 2004 16:21:27 GMT, Richard Clark
wrote:

On Sun, 5 Sep 2004 11:05:24 -0500, "Richard Fry"
wrote:

I trust my contention is now clear to you.


Hi OM,

Actually no. Your reference, Mendenhall, specifically writes about
his design:


Hi All,

I would add further, Mendenhall's notes of his design, as the model of
clarity, include references, one of which is particularly notable and
estimable within this group:
"Treman [sic], F.E.; "Electronic and Radio Engineering";
Mc Graw - Hill Book Co.; 1955"
the same publication I've had since the same date that Geoff built his
transmitter. Geoff's attachments also include the data sheets from
Eimac which show quite plainly that ALL of his formulas and
computations are congruent with ALL sources of information in his
references.

Another reference:
"Goodman, Byron (Ed.); 'The Radio Amateur's Handbook';
American Radio Relay League; Newton, Conn.;
1966"
(I used to have that publication, back then, too)

I also vaguely note some inference of peculiar intermodulation
products that would be produced by a transmitter with 50 Ohm output
characteristic - in that I may be mistaken because when the verbiage
gets particularly dense to explain simple matters, I must admit my own
filters kick in. However, Mendenhall's work was not simply that of an
amateur's project, nor was it a school term paper, nor was it the
speculation of an engineering sales pitch.

The report I am drawing upon was Geoff's own Type Acceptance
application to the FCC which included all the technical specifications
of spurs, intermodulation products, stability, efficiency (80%), class
of operation, modulation, out-of-band responses.... I don't think I
need go much further. :-)

For those who wish to read the COMPLETE story of how to build a rig,
how to specify it, how to measure it, and to note how it exactly
conforms to conventional wisdom; then visit:
http://www.techatl.com/wrek/docs/gnm_0011.htm
where you will find all of one page of theory, and 40 odd pages of
reality:
The WREK 425 Watt RF power amplifier, also known as the
"Goat-Mitter" was designed by Geoffrey N. Mendenhall (dubbed the
Goatman by WREK announcer, Ed Esserman) and constructed entirely
with hand tools by Geoff and the WREK staff in August of 1968.

73's
Richard Clark, KB7QHC

Richard Clark September 5th 04 06:06 PM

On Sun, 5 Sep 2004 11:25:02 -0500, "Richard Fry"
wrote:

You assume


Hi OM,

That is called a punt.

73's
Richard Clark, KB7QHC


All times are GMT +1. The time now is 04:01 PM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
RadioBanter.com