RadioBanter

RadioBanter (https://www.radiobanter.com/)
-   Antenna (https://www.radiobanter.com/antenna/)
-   -   Mismatch Uncertainty and an EZNEC transmission line sudy (https://www.radiobanter.com/antenna/2640-re-mismatch-uncertainty-eznec-transmission-line-sudy.html)

Roy Lewallen November 25th 04 10:47 PM

Mismatch Uncertainty and an EZNEC transmission line sudy
 
Richard Clark wrote:
. . .
I will add a proviso in that the Source represented by EZNEC, and
presumably by extension NEC, has no characteristic Zc; or rather I am
not aware of its value. . .


I'm not sure what Zc is, but NEC sources have a definite, well-defined
internal impedance: Zero. EZNEC gives you the choice of voltage sources,
which are the same as NEC sources, with an impedance of zero; and
current sources, which have an impedance of about 10^15 ohms --
infinite, for practical purposes.

Roy Lewallen, W7EL

Richard Clark November 26th 04 06:34 AM

On Thu, 25 Nov 2004 14:47:40 -0800, Roy Lewallen
wrote:

I'm not sure what Zc is, but NEC sources have a definite, well-defined
internal impedance: Zero. EZNEC gives you the choice of voltage sources,
which are the same as NEC sources, with an impedance of zero; and
current sources, which have an impedance of about 10^15 ohms --
infinite, for practical purposes.


Hi Roy,

You are too modest by half, you are sure. Such a source makes for the
explicit source of Mismatch Uncertainty.

73's
Richard Clark, KB7QHC