David Robbins September 5th 03 01:24 AM


wrote in message ...
Cecil Moore wrote:

Dr. Slick wrote:
If you agree that the Pref/Pfwd ratio cannot be greater than 1
for a passive network, then neither can the [Vref/Vfwd]= rho be
greater
than 1 either.


Sqrt(Pref/Pfwd) cannot be greater than one. (Z2-Z1)/(Z2+Z1) can be
greater than one. Both are defined as 'rho' but they are not
always equal.


On the other hand...

if
Vrev = rho * Vfwd
then
rho^2 = (Vrev^2/Z0) / (Vfwd^2/Z0)

So
(Vrev^2/Z0) / (Vfwd^2/Z0)
can be greater than one.

If Sqrt(Pref/Pfwd) can not be greater than 1
then either
Pfwd is not equal to (Vfwd^2/Z0)
or
Prev is not equal to (Vrev^2/Z0)

Intriguing result, is it not?


indeed... and directly to the crux of the whole problem. there are a few
too many powers being tossed around here without proper definition. i was
just looking at section 7.1 in 'Basic Circuit Theory' by Desoer and Kuh that
kind of sums up all the problems this discussion has been having in its
title "Instantaneous, Average, and Complex Power". for some reason this
section seems to have many more highlighted formulas than much of the rest
of the book.

I think many of our problems come from mis-applying power formulas to the
wrong cases. for example, the well known P=VI=V^2/R=I^2R takes a bit of
modification to work for general complex impedances.

lets look at the simple one first:
Instantaneous power: p(t)=v(t)i(t)
aha! you say, there it is, nice and simple.... but not so fast. this is in
the time domain. the Vfwd and Vrev we throw around so easily in phasor
notation when talking about transmission lines aren't the same thing and
can't be so easily converted... in fact, in going to the phasor notation you
intentionally throw away time information.... so in this case when you write
v(t) and i(t) in their full form they look like:
v(t)=|V| cos(wt+/_V)
i(t)=|I| cos(wt+/_I)
where w=omega, the angular rate, and /_ is used to denote the relative angle
at t=0....
thus expanding out this power formula you get and ugly thing:
p(t)=.5 |V| |I| cos(/_V-/_I) + .5 |V| |I| cos(2wt+/_V+/_I)
which when averaged becomes:
Pav=.5 |V| |I| cos(/_V - /_I)
which hopefully looks familiar to people out there who deal with power
factors and such.

Now, the odd one...
Complex Power:
P=.5 V I*
where V and I are the phasor representations used in sinusoidal steady state
analysis, and I* is the conjugate of I.
now here is where it gets weird...substituted in the exponential forms of
the phasors:
P=.5 |V| |I| e^(j(/_V-/_I))
oh for a good way to represent equations in plain text... but anyway, here
is a similar notation to the instantaneous power above, but there is no time
in it... only the magnitudes of the voltage and current multiplied by a
complex exponential from the difference in their phase angles. this can be
expanded into a sin/cos expression to separate the real and imaginary parts
like this:
P=.5 |V| |I| cos(/_V-/_I) + j.5 |V| |I| sin(/_V-/_I)
and from this you can show that the real part of this is the average power,
so:
Pav=.5 |V| |I| cos(/_V-/_I)
but since we are in phasor notation we can transform this one more time
using
V=ZI and I=YV (Y=1/Z, the complex admittance)
to get:
Pav= .5 |I|^2 Re[Z] = .5 |V|^2 Re[Y]

there are also a couple of important notes to go with this. in a passive
network Re[Z] and Re[Y] are both =0 which also constrains cos(/_V-/_I)
=0... essentially, no negative resistances in passive networks... which of

course then results in Pav always being positive(or zero).

now wait a minute you may say.. we have two different Pav equations... what
happens if we equate them??? (well, actually we have 4 different equations,
so lets play around a bit)

from time domain:
Pav=.5 |V| |I| cos(/_V - /_I)

from sinusoidal steady state:
Pav=.5 |V| |I| cos(/_V-/_I)
Pav= .5 |I|^2 Re[Z]
Pav= .5 |V|^2 Re[Y]

well, what do you know, the two methods give the same result (the first
formula of the sss method is the same as the time domain formula). but what
do the other two with the impedance and admitance do for us.... they show
that power in phasor calculations is not quite as simple as the
P=VI=V^2/R=I^2R we are used to... in fact, what are those equations good
for? basically, just for resistive circuits where I and V are in phase...
see section 7.3 of that reference for derivation of the I^2R power formula
for resistive loads... and also for how the rms value gets rid of that pesky
factor of .5 in all those equations to make I^2R work for sinusoidal
voltages... so I^2R and V^2/R are REALLY only good for rms voltages and
resistive loads. so you can't just use P=V^2/Z0 in the general case! but
didn't we all know that? after all, why is there a power factor added to
the calculation when working with reactive loads?? and why can you have
LOTS more reactive power in a circuit than real power??? don't believe in
reactive power? wait till the report about the blackout comes out, it was
basically run away loss of control of reactive power that probably resulted
in circulating currents that brought the grid to its knees.

so you are right:

Pfwd is not equal to (Vfwd^2/Z0)

and
Prev is not equal to (Vrev^2/Z0)


but by definition:

Vrev = rho * Vfwd


now, who really read and understood that???




Peter O. Brackett September 5th 03 02:05 AM

Slick:

[snip]
Are you gonna re-write some books?


Slick

[snip]

Did it ever occur to you that most textbook authors actually plagiarize each
other.

Since most textbooks have numerous competitors covering essentially the same
material, it is apparent that most of their content is not original, rather
lots of it is "copied" or re-written using a slightly different [improved]
notation and set of symbols.

Have you never noticed the same error in several textbooks by different
authors?

Why does that happen?

With how many textbook authors do you have a personal relationship?

Have you ever reviewed pre-publication drafts of textbooks for publishers...

Worked with authors on corrections to drafts before publication... believe
me if you have why then you would be a lot more cautious in taking textbooks
as gospel.

Textbooks that have become very popular and which have appeared in many
editions/printings are usually pretty good... but even then still often have
significant errata.

--
Peter K1PO
Indialantic By-the-Sea, FL.



Peter O. Brackett September 5th 03 02:08 AM

Cecil:

[snip]
"Cecil Moore" wrote in message
...
Dr. Slick wrote:
I can't wait to hook it up to see more reflected power than
incident on my DAIWA meter, that would be very interesting.


If that's really what you want to observe, connect the meter backwards.

:-)
--
73, Cecil http://www.qsl.net/w5dxp

[snip]

Or hook a transmitter to the remote end!

Heh, heh... what is the read out of reflected power on a full duplex DSL
line, with transmitters running full bore on both ends simultaneously.

Slick's exposure to real world transmission problems is very limited!

;-)

--
Peter K1PO
Indialantic By-the-Sea, FL.



Peter O. Brackett September 5th 03 02:11 AM

Cecil:

[snip]
rho = (50-50)/(50+50) = 0 i.e. no reflections in either direction
--
73, Cecil http://www.qsl.net/w5dxp

[snip]

Hey... that's my line.

That's Mother Nature's reflection coefficient!

At every infinitesimal length along a transmission line rho = (Zo - Zo)/(Zo
+ Zo) = 0.

It's not nice to fool Mother Nature!

--
Peter K1PO
Indialantic By-the-Sea, FL.



Peter O. Brackett September 5th 03 02:13 AM

Slick:

[snip]
I can't wait to hook it up to see more reflected power than
incident on my DAIWA meter, that would be very interesting.


Slick

[snip]

It sure will be an interesting event for your Daiwa when the transmitter
hooked to the other end is keyed!

--
Peter K1PO
Indialantic By-the-Sea, FL.



Peter O. Brackett September 5th 03 02:26 AM

Slick:

[snip]
Show us a passive circuit that reflects more power than
you feed it (incident), on my Daiwa meter,
and i will be VERY impressed.

I'm be waiting a long time for that schematic....


Slick

[snip]

That's an easy one... simply connect a negative resistance to the end of the
line.

And don't tell me that negative resistance is not passive!

--
Peter K1PO
Indialantic By-the-Sea, FL.



Roy Lewallen September 5th 03 02:42 AM

I have a few nits to pick with this analysis. Comments interspersed.

David Robbins wrote:

indeed... and directly to the crux of the whole problem. there are a few
too many powers being tossed around here without proper definition. i was
just looking at section 7.1 in 'Basic Circuit Theory' by Desoer and Kuh that
kind of sums up all the problems this discussion has been having in its
title "Instantaneous, Average, and Complex Power". for some reason this
section seems to have many more highlighted formulas than much of the rest
of the book.

I think many of our problems come from mis-applying power formulas to the
wrong cases. for example, the well known P=VI=V^2/R=I^2R takes a bit of
modification to work for general complex impedances.

lets look at the simple one first:
Instantaneous power: p(t)=v(t)i(t)
aha! you say, there it is, nice and simple.... but not so fast. this is in
the time domain. the Vfwd and Vrev we throw around so easily in phasor
notation when talking about transmission lines aren't the same thing and
can't be so easily converted... in fact, in going to the phasor notation you
intentionally throw away time information....


Here's my first point of disagreement. Phasor notation doesn't throw
away time information. It's still there, in implied form (as an implied
term exp(jwt)). And that's an important distinction, which I'll note
again shortly. One thing it means is that, given the phasor
representation of a waveform, it's possible to determine exactly what
the time waveform is -- you can convert back and forth at will. You do,
of course, have to know the implied radian frequency. If the time
information were thrown away, you wouldn't be able to do that.

so in this case when you write
v(t) and i(t) in their full form they look like:
v(t)=|V| cos(wt+/_V)
i(t)=|I| cos(wt+/_I)
where w=omega, the angular rate, and /_ is used to denote the relative angle
at t=0....
thus expanding out this power formula you get and ugly thing:
p(t)=.5 |V| |I| cos(/_V-/_I) + .5 |V| |I| cos(2wt+/_V+/_I)
which when averaged becomes:
Pav=.5 |V| |I| cos(/_V - /_I)
which hopefully looks familiar to people out there who deal with power
factors and such.


Fine so far.

Now, the odd one...
Complex Power:
P=.5 V I*
where V and I are the phasor representations used in sinusoidal steady state
analysis, and I* is the conjugate of I.



Problem here. As I mentioned above, a phasor contains an implied
frequency term. Phasors represent pure sine waves, and the frequency
*must be the same* for all phasors with which calculations are being
done. You can't use phasor analysis where the voltage, for example, is a
different frequency than the current, or to mix two voltages of
different frequencies. And that's the problem with the equation above.
It is *not* an equation for complex power. P is not, and cannot, be a
phasor, because its waveform has a different frequency than V and I. It
appears that you might be confusing this with an equation for *average*
power, which is:

P = Re{V I*}

with a .5 factor if V and I are peak values, and no .5 factor if they're
RMS. The result of this calculation is a purely real number, and the
same as you get with |V||I|cos(phiV - phiI).

Power can't be represented in phasor form. At least not in the same
analysis as the V and I it's composed of -- some clever PhD candidate
might have devised some use for a phasor analysis involving only power,
which could be done if you can find a consistent way to deal with
power's DC (average) component. But I've never seen such a method,
unless that's what Cecil is doing. So "complex power" doesn't have any
real meaning, although "instantaneous power", or time-domain power,
certainly does.

now here is where it gets weird...substituted in the exponential forms of
the phasors:
P=.5 |V| |I| e^(j(/_V-/_I))
oh for a good way to represent equations in plain text... but anyway, here
is a similar notation to the instantaneous power above, but there is no time
in it... only the magnitudes of the voltage and current multiplied by a
complex exponential from the difference in their phase angles. this can be
expanded into a sin/cos expression to separate the real and imaginary parts
like this:
P=.5 |V| |I| cos(/_V-/_I) + j.5 |V| |I| sin(/_V-/_I)
and from this you can show that the real part of this is the average power,
so:
Pav=.5 |V| |I| cos(/_V-/_I)
but since we are in phasor notation we can transform this one more time
using
V=ZI and I=YV (Y=1/Z, the complex admittance)
to get:
Pav= .5 |I|^2 Re[Z] = .5 |V|^2 Re[Y]


Because of what I said above, I don't believe that this is valid. You
simply can't calculate a phasor power from phasor V and I.

there are also a couple of important notes to go with this. in a passive
network Re[Z] and Re[Y] are both =0 which also constrains cos(/_V-/_I)

=0... essentially, no negative resistances in passive networks... which of


course then results in Pav always being positive(or zero).

now wait a minute you may say.. we have two different Pav equations... what
happens if we equate them??? (well, actually we have 4 different equations,
so lets play around a bit)

from time domain:
Pav=.5 |V| |I| cos(/_V - /_I)

from sinusoidal steady state:
Pav=.5 |V| |I| cos(/_V-/_I)
Pav= .5 |I|^2 Re[Z]
Pav= .5 |V|^2 Re[Y]

well, what do you know, the two methods give the same result (the first
formula of the sss method is the same as the time domain formula). but what
do the other two with the impedance and admitance do for us.... they show
that power in phasor calculations is not quite as simple as the
P=VI=V^2/R=I^2R we are used to...


I hope we're not used to that. It's an attempt to calculate phasor
power, which is doomed from the start.

in fact, what are those equations good
for? basically, just for resistive circuits where I and V are in phase...
see section 7.3 of that reference for derivation of the I^2R power formula
for resistive loads... and also for how the rms value gets rid of that pesky
factor of .5 in all those equations to make I^2R work for sinusoidal
voltages... so I^2R and V^2/R are REALLY only good for rms voltages and
resistive loads.


That's true. And the reason is that when V and I are in phase, then V =
|V| and I = |I|, and Z = |Z|, so you're simply calculating the average
power.

so you can't just use P=V^2/Z0 in the general case!

Absolutely not. Again, for the reason that you can't calculate a phasor
value of P from phasor V and I.

but
didn't we all know that? after all, why is there a power factor added to
the calculation when working with reactive loads??


Don't confuse power factor or its existence with the fundamental problem.

and why can you have
LOTS more reactive power in a circuit than real power???


Why not? It's very often the case.

don't believe in
reactive power? wait till the report about the blackout comes out, it was
basically run away loss of control of reactive power that probably resulted
in circulating currents that brought the grid to its knees.


The idea of reactive power follows easily from observation of the power
time waveform you described. The power becomes negative for part of the
cycle if V and I aren't exactly in phase. This represents energy flowing
back out of the circuit it flows into during the positive portion of the
cycle. If the power waveform is centered around zero, which it will be
if V and I are in quadrature, then the same amount of energy flows out
as flows in, so no work is done -- the power is entirely imaginary. And
the average value -- the waveform DC offset -- is zero. On the other
hand, if the waveform is entirely positive, which it is if V and I are
in phase, then energy flowing in never flows out, so the power is
entirely real, and the average is half the peak-to-peak waveform value.
Real power represents the power that flows in without a corresponding
outward flow; reactive power is that which goes in and comes back out.


so you are right:


Pfwd is not equal to (Vfwd^2/Z0)


and

Prev is not equal to (Vrev^2/Z0)



but by definition:


Vrev = rho * Vfwd



now, who really read and understood that???


I hope I did. If not, please correct me.

Roy Lewallen, W7EL


Dr. Slick September 5th 03 09:34 AM

"Peter O. Brackett" wrote in message hlink.net...
Slick:

[snip]
Show us a passive circuit that reflects more power than
you feed it (incident), on my Daiwa meter,
and i will be VERY impressed.

I'm be waiting a long time for that schematic....



That's an easy one... simply connect a negative resistance to the end of the
line.

And don't tell me that negative resistance is not passive!



I most certainly WILL tell you that! A negative resistance can be found
in a tunnel diode, but you still need to apply a supply voltage to make
it an oscillator.

Negative resistance implies positive feedback, so i would certainly be
an active device.

Ok, show me your schematic, then.........waiting a long time......


Slick

Dr. Slick September 5th 03 10:09 AM

"David Robbins" wrote in message ...


yeah, verily...

note some interesting things about the case you present...

first, to get it out of the way. as i have stated elsewhere in this thread
today the VSWR calculation from rho is really only applicable to lossless
lines because of the simplifications needed to calculate it from
|Vmax|/|Vmin| which is its real definition. and since Vmax and Vmin are not
the same in any two points on a lossy line it really doesn't have much
physical significance either.



Zo and Zl can be the impedances at a connector, with NO
TRANSMISSION LINE.

Zo can be the impedance at the END of a transmission line.

VSWR = ([rho]+1)/([rho]-1) only works for 0=[rho]=1

or situations of return LOSS, not return GAIN (active networks)!



the actual value of rho for this case is -.9372-1.60477i (which mathcad
gives me as 1.8585/_120.283 but i started from R,G,L,C values and only got
it down to Zo=301.5-250.3i which is close enough for this discussion i
think)

now, how can this be real... the important case is to look at the voltages
at the line/load junction. at this point Vf+Vr=Vl according to the
derrivation of rho. so what do we get with a rho like this???

for Vf=1.0v
Vr=rho*Vf = -.9372+1.60477i
and then
Vl=.06279+1.60477i

so there is a small real voltage across the 10+250i load, and a large
reactive voltage... the reactive voltage is equal to a reactive voltage on
the transmission line side of the junction.... can i believe this? I am
still working on that, in some ways it makes sense because you no longer
have a purely resistive cable characteristic, though i haven't come to grips
with the physical meaning of it yet. i do believe that it has a
relationship to circulating currents and reactive power in power
distribution circuits where you can get very odd looking voltages and
currents when you have a reactive load. in looking at this you have a very
capacitive looking line feeding a very inductive load, with a bit of
resistance thrown in on each side... essentially it looks like a current
pumping a resonant circuit which can result in very high voltages and
currents.



But you will never get a Reflected voltage that is greater than
the
incident in a passive network. Sure, you may have an inductor
charging up a capacitor somewhere in a resonant circuit (like parallel
resonance, with
a "fly-wheel" effect). But this voltage will not be reflected.



on the other side, the rho calculated with the conjugate in the numerator
gives: -.9358-.001688i or .9358/_-179.9


Which makes WAY more sense than the "normal" equation result.

Consider: Zo=300-j250 and Zl=10+j250

Essentially, the two reactances should cancel, and it will be
identical to Zo=300 and Zl=10.

Now, this should be fairly close to a short (Zl=0), which it
really is, in the sense that almost all the voltage is reflected
and the phase shift is almost -180 (-179.9), as it should be for
a near-short.

The "Normal" equation's results of: RC = 1.8585/_120.283 is
absolutely
incorrect. You can't use the normal equation for complex Zo!

You folks can believe what you want, but you are convincing me
more that Besser and Kurokawa and the ARRL are all correct on this
one.

I won't hesistate to admit that i'm wrong, but nothing has been
presented to convince me of that.




btw, for whom ever has it... i am still waiting to see the derivation of the


conjugate rho formula. i published one on here for the 'classical' version,
where is the other one???



I'll send you the paper...

I'd like to see the derivation too, as Kurokawa seems to skip it
or just copied it from another paper! haha...

Anyways, it's the correct formula for complex Zo, you've
convinced me of that with this post.

Thank you for your time and effort David.


Slick (Garvin)

Dr. Slick September 5th 03 10:19 AM

"Peter O. Brackett" wrote in message thlink.net...
Cecil:

[snip]
"Cecil Moore" wrote in message
...
Dr. Slick wrote:
I can't wait to hook it up to see more reflected power than
incident on my DAIWA meter, that would be very interesting.


If that's really what you want to observe, connect the meter backwards.

:-)
--
73, Cecil http://www.qsl.net/w5dxp



Ha! that would be the ONLY way, if you are going into a passive
network like coax and antenna.




Or hook a transmitter to the remote end!

Heh, heh... what is the read out of reflected power on a full duplex DSL
line, with transmitters running full bore on both ends simultaneously.

Slick's exposure to real world transmission problems is very limited!


Not as limited as yours, it would seems! ;^)

Show me an antenna-coax network that reflects more power than
incident! Impossible!


Slick

David Robbins September 5th 03 11:46 AM


"Roy Lewallen" wrote in message
...
I have a few nits to pick with this analysis. Comments interspersed.

David Robbins wrote:

indeed... and directly to the crux of the whole problem. there are a

few
too many powers being tossed around here without proper definition. i

was
just looking at section 7.1 in 'Basic Circuit Theory' by Desoer and Kuh

that
kind of sums up all the problems this discussion has been having in its
title "Instantaneous, Average, and Complex Power". for some reason this
section seems to have many more highlighted formulas than much of the

rest
of the book.

I think many of our problems come from mis-applying power formulas to

the
wrong cases. for example, the well known P=VI=V^2/R=I^2R takes a bit of
modification to work for general complex impedances.

lets look at the simple one first:
Instantaneous power: p(t)=v(t)i(t)
aha! you say, there it is, nice and simple.... but not so fast. this is

in
the time domain. the Vfwd and Vrev we throw around so easily in phasor
notation when talking about transmission lines aren't the same thing and
can't be so easily converted... in fact, in going to the phasor notation

you
intentionally throw away time information....


Here's my first point of disagreement. Phasor notation doesn't throw
away time information. It's still there, in implied form (as an implied
term exp(jwt)). And that's an important distinction, which I'll note
again shortly. One thing it means is that, given the phasor
representation of a waveform, it's possible to determine exactly what
the time waveform is -- you can convert back and forth at will. You do,
of course, have to know the implied radian frequency. If the time
information were thrown away, you wouldn't be able to do that.

so in this case when you write
v(t) and i(t) in their full form they look like:
v(t)=|V| cos(wt+/_V)
i(t)=|I| cos(wt+/_I)
where w=omega, the angular rate, and /_ is used to denote the relative

angle
at t=0....
thus expanding out this power formula you get and ugly thing:
p(t)=.5 |V| |I| cos(/_V-/_I) + .5 |V| |I| cos(2wt+/_V+/_I)
which when averaged becomes:
Pav=.5 |V| |I| cos(/_V - /_I)
which hopefully looks familiar to people out there who deal with power
factors and such.


Fine so far.

Now, the odd one...
Complex Power:
P=.5 V I*
where V and I are the phasor representations used in sinusoidal steady

state
analysis, and I* is the conjugate of I.



Problem here. As I mentioned above, a phasor contains an implied
frequency term. Phasors represent pure sine waves, and the frequency
*must be the same* for all phasors with which calculations are being
done. You can't use phasor analysis where the voltage, for example, is a
different frequency than the current, or to mix two voltages of
different frequencies. And that's the problem with the equation above.
It is *not* an equation for complex power. P is not, and cannot, be a
phasor, because its waveform has a different frequency than V and I. It
appears that you might be confusing this with an equation for *average*
power, which is:


i didn't say Pcomplex was a phasor. in fact it's 'frequency' would be twice
the V and I frequency. as the derivation continues you can calculate the
average power from it though as shown below...


P = Re{V I*}

with a .5 factor if V and I are peak values, and no .5 factor if they're
RMS. The result of this calculation is a purely real number, and the
same as you get with |V||I|cos(phiV - phiI).


RMS is a whole different problem that simplifies the equation even further.


Power can't be represented in phasor form. At least not in the same
analysis as the V and I it's composed of -- some clever PhD candidate
might have devised some use for a phasor analysis involving only power,
which could be done if you can find a consistent way to deal with
power's DC (average) component. But I've never seen such a method,
unless that's what Cecil is doing. So "complex power" doesn't have any
real meaning, although "instantaneous power", or time-domain power,
certainly does.


ah, but it does and when used as defined.... it is an odd concept and rarely
used but it is a way to represent power which keeps intact the phase
relationship it came from.


now here is where it gets weird...substituted in the exponential forms

of
the phasors:
P=.5 |V| |I| e^(j(/_V-/_I))
oh for a good way to represent equations in plain text... but anyway,

here
is a similar notation to the instantaneous power above, but there is no

time
in it... only the magnitudes of the voltage and current multiplied by a
complex exponential from the difference in their phase angles. this can

be
expanded into a sin/cos expression to separate the real and imaginary

parts
like this:
P=.5 |V| |I| cos(/_V-/_I) + j.5 |V| |I| sin(/_V-/_I)
and from this you can show that the real part of this is the average

power,
so:
Pav=.5 |V| |I| cos(/_V-/_I)
but since we are in phasor notation we can transform this one more time
using
V=ZI and I=YV (Y=1/Z, the complex admittance)
to get:
Pav= .5 |I|^2 Re[Z] = .5 |V|^2 Re[Y]


Because of what I said above, I don't believe that this is valid. You
simply can't calculate a phasor power from phasor V and I.


as i said, its not phasor power, it is complex power. there is no attempt
made to show that it represents a phasor.

there are also a couple of important notes to go with this. in a

passive
network Re[Z] and Re[Y] are both =0 which also constrains cos(/_V-/_I)

=0... essentially, no negative resistances in passive networks... which

of

course then results in Pav always being positive(or zero).

now wait a minute you may say.. we have two different Pav equations...

what
happens if we equate them??? (well, actually we have 4 different

equations,
so lets play around a bit)

from time domain:
Pav=.5 |V| |I| cos(/_V - /_I)

from sinusoidal steady state:
Pav=.5 |V| |I| cos(/_V-/_I)
Pav= .5 |I|^2 Re[Z]
Pav= .5 |V|^2 Re[Y]

well, what do you know, the two methods give the same result (the first
formula of the sss method is the same as the time domain formula). but

what
do the other two with the impedance and admitance do for us.... they

show
that power in phasor calculations is not quite as simple as the
P=VI=V^2/R=I^2R we are used to...


I hope we're not used to that. It's an attempt to calculate phasor
power, which is doomed from the start.


thats what i said, you can't use the simple VI formula with phasors to
directly get power.


in fact, what are those equations good
for? basically, just for resistive circuits where I and V are in

phase...
see section 7.3 of that reference for derivation of the I^2R power

formula
for resistive loads... and also for how the rms value gets rid of that

pesky
factor of .5 in all those equations to make I^2R work for sinusoidal
voltages... so I^2R and V^2/R are REALLY only good for rms voltages and
resistive loads.


That's true. And the reason is that when V and I are in phase, then V =
|V| and I = |I|, and Z = |Z|, so you're simply calculating the average
power.

so you can't just use P=V^2/Z0 in the general case!

Absolutely not. Again, for the reason that you can't calculate a phasor
value of P from phasor V and I.

but
didn't we all know that? after all, why is there a power factor added

to
the calculation when working with reactive loads??


Don't confuse power factor or its existence with the fundamental problem.

and why can you have
LOTS more reactive power in a circuit than real power???


Why not? It's very often the case.


why not??? i didn't say your couldn't, i said you do often have lots of
reactive power.... i think you have lost track of what i was trying to show.


don't believe in
reactive power? wait till the report about the blackout comes out, it

was
basically run away loss of control of reactive power that probably

resulted
in circulating currents that brought the grid to its knees.


The idea of reactive power follows easily from observation of the power
time waveform you described. The power becomes negative for part of the
cycle if V and I aren't exactly in phase. This represents energy flowing
back out of the circuit it flows into during the positive portion of the
cycle. If the power waveform is centered around zero, which it will be
if V and I are in quadrature, then the same amount of energy flows out
as flows in, so no work is done -- the power is entirely imaginary. And
the average value -- the waveform DC offset -- is zero. On the other
hand, if the waveform is entirely positive, which it is if V and I are
in phase, then energy flowing in never flows out, so the power is
entirely real, and the average is half the peak-to-peak waveform value.
Real power represents the power that flows in without a corresponding
outward flow; reactive power is that which goes in and comes back out.


so you are right:


Pfwd is not equal to (Vfwd^2/Z0)


and

Prev is not equal to (Vrev^2/Z0)



but by definition:


Vrev = rho * Vfwd



now, who really read and understood that???


I hope I did. If not, please correct me.

Roy Lewallen, W7EL




David Robbins September 5th 03 11:47 AM


"Dr. Slick" wrote in message
om...
"David Robbins" wrote in message

...
"Dr. Slick" wrote in message
m...
Cecil Moore wrote in message

...
Dr. Slick wrote:
If you agree that the Pref/Pfwd ratio cannot be greater than

1
for a passive network, then neither can the [Vref/Vfwd]= rho be
greater
than 1 either.

Sqrt(Pref/Pfwd) cannot be greater than one. (Z2-Z1)/(Z2+Z1) can be
greater than one. Both are defined as 'rho' but they are not
always equal. (Z2-Z1)/(Z2+Z1) is a physical reflection coefficient.
Sqrt(Pref/Pfwd) is an image reflection coefficient.


I agree that Sqrt(Pref/Pfwd) cannot be greater than one for a
passive network.

(Z2-Z1)/(Z2+Z1) can be greater than one, for passive networks
and certain combinations of complex Z1 and Z2. I feel this is

incorrect
usage of this formula, which should be limited to purely real Zo.
A [rho] that is greater than one gives meaningless negative SWR
data, and is limited to active devices.

it only gives negative swr values if you incorrectly use the lossless

line
approximation to calculate vswr from rho. that is the incorrectly

applied
formula in this case. that formula is not valid for a lossy line, you

must
go back to the original definition of VSWR=|Vmax|/|Vmin|. which as we

have
also noted is not meaningful on a lossy line as Vmax and Vmin are

different
at each max and min point because of the losses in the line affecting

both
the forward and reverse waves.



What if Z1 represents the impedance at the end of the line? Then
it doesn't matter what the losses are. Then you are trying to find
the
RC right at the meeting of the line and the load, so you don;t care
what the
losses of the line are.

Slick


but Vmax and Vmin don't occur at the same location on the line. when
measuring Vmax and Vmin you have to look 1/4 wave apart on the line... so by
definition it is a distributed measurement so losses do matter.



W5DXP September 5th 03 03:36 PM

Dr. Slick wrote:
I'd like to see the derivation too, as Kurokawa seems to skip it
or just copied it from another paper! haha...


The point that you may have missed is that Kurokawa invents a different
kind of wave called a "Power Wave". He dismisses traveling waves as not
being very useful. So, of course, with the invention of a different kind
of wave, he is free to introduce a different kind of reflection coefficient.
The mistake being made here is trying to assume that his different kind of
reflection coefficient applies to normal forward and reflected traveling
waves. It doesn't.
--
73, Cecil, W5DXP


W5DXP September 5th 03 03:40 PM

Dr. Slick wrote:
Show me an antenna-coax network that reflects more power than
incident! Impossible!


I've pretty much proven that it can't happen. Simply insert one
wavelength of lossless feedline between the lossy feedline and
the reactive load. Everything becomes clear.
--
73, Cecil, W5DXP


W5DXP September 5th 03 03:58 PM

David Robbins wrote:
but Vmax and Vmin don't occur at the same location on the line. when
measuring Vmax and Vmin you have to look 1/4 wave apart on the line... so by
definition it is a distributed measurement so losses do matter.


The measured 'rho' at any *point* can be determined by Sqrt(Pref/Pfwd).
That means, for lossy lines, measured SWR increases toward the load and
decreases toward the source. An open-ended 400 ft. piece of RG-58 will
show a near perfect SWR at the source end on 440 MHz.
--
73, Cecil, W5DXP


Reg Edwards September 5th 03 04:24 PM

Reference Dr. Best's QEX article.

===============================

Who is Dr. Best? Would it be Dr Who with his Daleks?

And what is QEX.

99.999 percents of the world's population has never heard of either.



W5DXP September 5th 03 05:17 PM

Reg Edwards wrote:

Reference Dr. Best's QEX article.


Who is Dr. Best? Would it be Dr Who with his Daleks?


Dr. Best is the ham who started all this mess when he posted parts
of his QEX article to this newsgroup in May of 2001.

And what is QEX.


QEX is a technical magazine publication of the ARRL.

99.999 percents of the world's population has never heard of either.


What percentage of the world's population are US hams? I'll bet at
least 20% of them have heard of QEX magazine.
--
73, Cecil, W5DXP


Harold E. Johnson September 5th 03 05:19 PM


Who is Dr. Best? Would it be Dr Who with his Daleks?

And what is QEX.

99.999 percents of the world's population has never heard of either.


Yea, but those of us who matter, know both, and have been to Llangollen!

W4ZCB



Peter O. Brackett September 5th 03 07:10 PM

Slick:

[snip]
Not as limited as yours, it would seems! ;^)

Show me an antenna-coax network that reflects more power than
incident! Impossible!


Slick

[snip]

Ever operate your antenna coax in the near field of a commerical broadcast
antenna?

Guess what the reflected power reads?

RF applications, Ham antennas and transmission lines are ho-hum
technology...

Such simple applications do not present any great analysis difficulty or
operating
challenges, they are approximately lossless and distortionless and always
operated narrow band with a purely resistive Zo =50 Ohms.

The question of complex Zo never arises in ham applications or most other
RF applications for that matter...

The most difficult transmission line problems for design and analysis are
those
operating in what is known as DSL [digital subscriber loop] technology and
similar applications.

In the DSL application the Zo of the line, up to 18,000 feet of twisted pair
with at leat 1500 Ohms of DC resistance, is extremely complex and varies
all over the map over 5 - 6 decades of operating frequency range from DC
to tens of MegaHz, supported by full duplex transmitters transmitting
simulaneously
at full power on both ends with the receivers hooked directly to the same
ends.

If you have succesfully designed transceivers to operate on those lines,
maintained
by span powering from one end and shipped in the millions world wide as I
have, why
then my friend you may claim to know something about complex Zo and
reflection
coefficients.

--
Peter K1PO
Indialantic By-the-Sea, FL



Dr. Slick September 6th 03 12:14 AM

W5DXP wrote in message ...
David Robbins wrote:
but Vmax and Vmin don't occur at the same location on the line. when
measuring Vmax and Vmin you have to look 1/4 wave apart on the line... so by
definition it is a distributed measurement so losses do matter.


The measured 'rho' at any *point* can be determined by Sqrt(Pref/Pfwd).
That means, for lossy lines, measured SWR increases toward the load and
decreases toward the source. An open-ended 400 ft. piece of RG-58 will
show a near perfect SWR at the source end on 440 MHz.



I agree with both of you on this one.

This is why people will tell you that your SWR meter should really
be
at the antenna, instead of at the end of 100 ft. of RG-58, if you
wanna measure the SWR at the attenna!

Absolutely agrees with everything i know up to this point.

But, you SWR meter is at one point only! You don't have to
measure at two places 1/4 wave apart! This is because the SWR is
based on the forward and reflected powers.

But i agree, if you move 200 feet down RG-58 from the SWR meter at
the antenna, the SWR will most certainly improve!

My point is that the RC equation calculated the RC at one point,
and so the SWR equation will also apply at that ONE point.

But if you want to get the SWR 200 feet down the line, you will
have to
move the SWR meter and measure at the new location.


Slick

Dr. Slick September 6th 03 12:25 AM

W5DXP wrote in message ...
Dr. Slick wrote:
The concept of phase is meaningless for power.


Actually, in a transmission line, it's not. Reference Dr. Best's
QEX article. He introduces a term familiar to the field of optics:

P1 + P2 + Sqrt(P1*P2)cos(delta)

where delta is the angle between V1 and V2.

Sqrt(P1*P2)cos(delta) is the interference term whose magnitude
depends on the phase between two voltages. If the phase between
V1 and V2 is less than 90 deg, the sign of that term is positive
and the interference is constructive. If the phase angle between
V1 and V2 is between 90 deg and 180 deg, the sign of that term
is negative and the interference is destructive.



Ok, well perhaps Dr. Best is talking about constructive and
destructive
interference, but i'm just talking about incident and reflected power.

Page 32 of "Electronic Applications of the Smith Chart":

"The power RC is defined simply as the ratio of the
reflected to the
incident power in a waveguide. Numerically it is equivalent to the
square
of the voltage reflection coefficient (atually, this should be
Magnitude-Slick).
However, unlike the voltage RC, the power RC has magnitude only, since
'phase' as applied to power is meaningless."


Slick

Cecil Moore September 6th 03 12:28 AM

Dr. Slick wrote:
But his original formulas for ai and bi (incident and reflected
voltage waves) are quite confusing in terms of subscripts, and he
doesn't show us the derivation for the conjugate RC formula, unfortunately.


He has simply invented a new model. There are a lot of them. From
now on, go through a binary decision tree to see if someone is
repeating the past or is offering something new.
--
73, Cecil http://www.qsl.net/w5dxp



-----= Posted via Newsfeeds.Com, Uncensored Usenet News =-----
http://www.newsfeeds.com - The #1 Newsgroup Service in the World!
-----== Over 100,000 Newsgroups - 19 Different Servers! =-----

Cecil Moore September 6th 03 12:31 AM

Dr. Slick wrote:
Ok, well perhaps Dr. Best is talking about constructive and destructive
interference, ...


Yes, he was, but unfortunately he didn't realize it until a few weeks
after I told him. :-)
--
73, Cecil http://www.qsl.net/w5dxp



-----= Posted via Newsfeeds.Com, Uncensored Usenet News =-----
http://www.newsfeeds.com - The #1 Newsgroup Service in the World!
-----== Over 100,000 Newsgroups - 19 Different Servers! =-----

[email protected] September 6th 03 01:48 AM

"Dr. Slick" wrote:
ok, Keith, i look forward with great interest on your
imaginary passive circuit which can reflect more power than
what you feed it (incident power).

I can't wait to hook it up to see more reflected power than
incident on my DAIWA meter, that would be very interesting.


I would never claim there is a passive circuit which violated
the rules of conservation of energy but if you define
A = Vf**2/Z0
and
B = Vr**2/Z0
then there are circuits for which B is greater than A and if you
accept the often held view that Pfwd = A and Prev = B then YOU
are also claiming the Pref is greater than Pfwd. I claim that A
and B don't, in reality, have much to do with power at all.

On the other hand Vr Vf has been demonstrated by several
examples of which Roy's August 20 post

http://groups.google.ca/groups?dq=&hl=en&lr=&ie=UTF-8
&threadm=vl88o381tks0cc%40corp.supernews.com
&prev=/groups%3Fdq%3D%26num%3D25%26hl%3Den%26lr%3D%26ie%3 DUTF-8
%26group%3Drec.radio.amateur.antenna%26start%3D25

is just one example.

This example had a line with Z0 of 68-j39 ohms connected to a load
with impedance 10+j50 ohms.

While this example demonstrated lossy lines, for this analysis
we can simplify the line to its Thevenin equivalent:
- an ideal voltage source
- producing a 10 kHz sinusoid
- at 52.68 V
- with a source impedance of 68-j39 ohms
connected to a load of 10+j50 ohms.

The incident voltage is 26.34 V.

Using polar notation...
- source voltage: 52.68/_ 0.0 [52.68+j0.0] V
- source impedance: 78.4/_ -29.8 [68-j39] ohms
- load impedance: 51.0/_ 8.7 [10+j50] ohms

Total circuit impedance is source + load impedance:
78.4/_ -29.8 + 51.0/_ 8.7 = 78.8/_ 8.03 [78+j11]
Circuit current (voltage/impedance)
52.68/_ 0.0 / 78.8/_ 8.03 = 0.669/_ -8.03 [0.662-j0.0934]
Voltage at load (current * impedance)
0.669/_ -8.03 * 51.0/_ 8.7 = 34.1/_ 70.7 [11.3+j32.2]
which agrees with Roy's.
Reflected voltage (load voltage - incident)
34.1/_ 70.7 - 26.34/_ 0.0 = 35.5/_ 115.1 [-15.0+j32.2]
which also agrees.

So reflected voltage is greater than incident voltage
which leads to rho being greater than unity.

Now about that Daiwa....

Directional wattemeters compute the Vf and Vr using
Vf = (V + I*Z0) /2
Vr = (V - I*Z0) /2

Your Daiwa is probably calibrated for Z0 = 50 ohms, but let's
assume we can recalibrate for Z0 = 78.4/_ -29.8 [68-j39] ohms.

Then it will obtain
Vf = (34.1/_ 70.7 + 0.669/_ -8.03 * 78.4/_ -29.8) /2
= 26.34/_ 0.0 [26.34+j0.0]
Vr = (34.1/_ 70.7 - 0.669/_ -8.03 * 78.4/_ -29.8) /2
= 35.5/_ 115.1 [-15.0+j32.2]
as expected. Please note that your Daiwa DOES think that
Vr is greater than Vf.

Assuming your Daiwa works like most directional wattmeters
it will feed these voltages (appropriately scaled) to a
meter which will move linearly in response to the voltage.

So if your Daiwa had a linear scale it would have no
difficulty showing Vf and Vr (except that it would need
to be adjusted for the different Z0) and it would show
a greater Vr than Vf (i.e. rho 1).

But displaying power (even though meaningless in this case)
is somewhat more difficult. Your Daiwa likely computes power
by having non-linear markings on the meter representing
V**2/Z0. This works fine for real Z0, but will not do for
complex Z0. For this, you need more sophosticated computation
than is possible with just a non-linear scale, so the
power indicated by your Daiwa will be quite incorrect.

But it does get Vf and Vr correct (assuming it is adjusted for
the different Z0).

....Keith

Peter O. Brackett September 6th 03 02:27 AM

David:

[snip]
"David Robbins" wrote in message
...

"Peter O. Brackett" wrote in message
.net...
Slick:

What about a negative inductance for a load? A negative capacitance?

And
don't tell me those are not passive!


a negative inductance is a capacitance, and a negative capacitance is an
inductance! and yes, they are both passive!

[snip]

You are only half correct David.

They are both passive, but a negative inductance certainly is NOT a
capacitor.

And a negative capacitor certainly is NOT an inductor.

Compare the expressions below to convince yourself of the truth of this
assertion.

The inductive reactance for a positive inductor is:

X = j*w*L

of a negative inductor

X = -j*w*L

of a positive capacitor

X = 1/j*w*C = -j/w*C

of a negative capacitor

X = 1/-j*w*C = j/w*C

The magnitude of the reactance of a negative inductor goes up with frequency
while the magnitude of a capacitor goes down with frequency, etc...

I have synthesized filters with both negative inductors and negative
capacitors, they are theoretically passive and they do work.

--
Peter K1PO
Indialantic By-the-Sea, FL