Whoa, I did that experiment for Slick a month ago. I replaced the short
piece of LMR240 between the transmitter and Kenwood SW2000 meter with a precisely measured 1/4 wavelength piece of RG59 75 Ohm coax. The loading changed, as expected, but the SWR reading did NOT change for SWR values of 1:1 and 1.6:1. The transmitter now saw a load of 112.5 Ohms. The Kenwood now saw a different source impedance. I don't see any inconsistency. 100W into 112.5 Ohms requires a voltage of 106V RMS. In a transmitter with a fixed ratio output transformer that may not be doable. It is designed to put out 70.7V RMS into 50 Ohms, with some margin. Tam/WB2TT "Reg Edwards" wrote in message ... To anybody interested. We have a HF Transmitter + 50-ohm coax + SWR meter + Tuner + Feedline of any Zo + Antenna. Suppose it is all tuned-up and ready to go. The transmitter is loaded with exactly 50-ohms resistive. Now change the 50-ohm coax to shorter length of 75-ohm Zo. As everybody agrees (after perhaps a little meter recalibration) the SWR meter indication will not change. BUT THE TRANSMITTER WILL NOW BE INCORRECTLY LOADED. Where does the inconistency lie ? Does it lie in the change in effective source impedance? |