(yet another) transmission line question
More for the fun of pondering it than for any immediate practical
reason... If I make a balanced two-wire transmission line from round wires, and I'm constrained to have the wire center-to-center spacing some particular value (say one inch, or five centimeters, or whatever), what wire diameter should I use to get the lowest matched-line loss? What impedance line does that give (assuming air dielectric)? Clearly for a given wire diameter, the wider the spacing the lower the loss up to the point where radiation plus dielectric loss becomes significant, but I can imagine situations where you want to limit the wire spacing and get low loss. Cheers, Tom |
Unless I goofed up the math (a distinct possibility), the answer is that
you want a Z0 of about 144 ohms, which is a spacing/diameter ratio of about 1.81. This was pretty easy to solve via differentiation using the approximation Z0 ~ 120 * ln(2S/d) where S = the center-to-center wire spacing and d is the wire diameter. The answer I got was 120 ohms, or d = 2S/e, or S/d ~ 1.36. Unfortunately, this spacing is too close for the approximation to be accurate, so the answer wasn't good. When I used the full inverse hyperbolic cosine formula for Z0 and took the necessary derivative, I found the resulting equation too messy to solve in closed form. So I went brute force and used a simple program to iterate and spot the maximum. It looks to me like you need to maximize d * Z0 in order to minimize the loss (see below). Don't trust my answer without some checking -- I did it pretty quickly so there's lots of room for error. It's good to have an opportunity to dust off the neurons once in a while. Thanks. ------ Loss per unit length = attenuation constant alpha = 1/2 * (R/R0 + G/G0) nepers/m. With air dielectric, G ~ 0, so alpha = R/(2*R0), where R = AC resistance per meter (both wires) and R0 = (assumed purely real) Z0. Assuming skin effect is fully developed, R ~ k / d where d = wire diameter and k depends on frequency, resistivity, and permeability of the wire but not on d, S, or Z0. So alpha = k / (2 * d * R0). This shows that minimizing alpha (loss) requires maximizing d * R0, which appears to occur when R0 ~ 144 ohms (S/d ~ 1.81). ----- Roy Lewallen, W7EL K7ITM wrote: More for the fun of pondering it than for any immediate practical reason... If I make a balanced two-wire transmission line from round wires, and I'm constrained to have the wire center-to-center spacing some particular value (say one inch, or five centimeters, or whatever), what wire diameter should I use to get the lowest matched-line loss? What impedance line does that give (assuming air dielectric)? Clearly for a given wire diameter, the wider the spacing the lower the loss up to the point where radiation plus dielectric loss becomes significant, but I can imagine situations where you want to limit the wire spacing and get low loss. Cheers, Tom |
As he says, Roy's resulta are very approximate. That's mainly because
he neglected proximity effect between the wires. A better approximation is obtained by incorporating an approximate expression for proximity effect. However, this makes differentiation of the loss formula with respect to wire diameter ridiculously tedious. So I found minimum loss by plotting a graph with a pocket calculator and searching for it. At HF when skin effect is fully effective, and neglecting dielectric loss in comparison with conductor loss - For a fixed wire spacing, as wire diameter increases, the wires get closer together and proximity loss eventually increases faster than ordinary loss decreases due to the increase in diameter. Thus minimum loss occurs at a smaller diameter and a greater Spacing/Diameter ratio. The Ro at which minimum loss occurs is independent of both frequency and wire conductivity. Results are - Ro = 177 ohms. Spacing between wire centres is 2.29 times wire diameter. Which demonstrates that mathematics is vastly superior and takes priority over practical experiments and making measurements. From an engineering point of view, K7ITM asked the wrong question. He should have asked, for a given wire spacing, what wire diameter minimises the cost of the copper. Or something like that. Many years back a similar sort of calculation was done for coax. Coax does not suffer from proximity effect. It's easier to work out. The answer was 75 ohms. That's how 75 ohms became the standard comunications Ro. There are many millions of miles of the stuff. The Chinese are now making even more of it. ---- Reg, G4FGQ |
Reg Edwards wrote:
Many years back a similar sort of calculation was done for coax. Coax does not suffer from proximity effect. It's easier to work out. The answer was 75 ohms. That's how 75 ohms became the standard comunications Ro. I vaguely remember something about efficiency Vs power handling capability being the difference in the 75 ohm standard and the 50 ohm standard. Is that right? -- 73, Cecil http://www.qsl.net/w5dxp ----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups ----= East and West-Coast Server Farms - Total Privacy via Encryption =---- |
Cecil Moore wrote:
Reg Edwards wrote: Many years back a similar sort of calculation was done for coax. Coax does not suffer from proximity effect. It's easier to work out. The answer was 75 ohms. That's how 75 ohms became the standard comunications Ro. I vaguely remember something about efficiency Vs power handling capability being the difference in the 75 ohm standard and the 50 ohm standard. Is that right? -- 73, Cecil http://www.qsl.net/w5dxp ----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups ----= East and West-Coast Server Farms - Total Privacy via Encryption =---- Page 5-15 of The ARRL UHF/Microwave Experimenter's Manual says: "Consider that both power handling capability and cable losses vary with Zo. It has been shown that cable losses are minimum at a characteristic impedance on the order of 75 [Ohms], while power handling capability is maximum at a Zo of about 30 [Ohms]." (The book used the Greek symbol rather than [Ohms]) The quoted passage is in a chapter by Dr. Paul Shuch, N6TX, Professor of Electronics, Pennsylvania College of Technology. At the end of the quote, is an indication to see footnote 13 which is: "Moreno, Theodore, Microwave Transmission Design Data, Dover Publications, 1948." 73, John |
Cecil Moore, W5DXP wrote:
"I vaguely remember something about efficiency versus power handling capability being the difference in the 75 ohm standard and the 50 ohm standard." That seens exactly right. It`s the reason you would use 75-ohm Zo cable for TV distribution at low-power where you want to minimize loss but there is no danger of too much voltage flashing over the cable. Terman in his 1955 edition on page 106 says: "---in an air-insulated coaxial line of given outer radius b, Q will be maximum when the inner conductor has a size such thet b/a = 3.6. (b=inner radius of outer conductor in concentric line, and a=outer radius of inner conductor in concentric line) corresponding to Zo = 77 ohms. These are also the proportions for minimum power loss----." However the maximum power that can be transmitted without exceeding a given voltage gradient occurs when b/a 1.65, giving Zo = 30 ohms." So for minimum loss you would want Zo of about 75 ohms and for maximum power capability you would want 30 ohms. I suspect Zo=50 ohms is a compromise between power handling capability and reasonable loss. Best regards, Richard Harrison, KB5WZI |
You're correct, I neglected proximity effect. And the wires are close
enough that it's a factor. What is the approximate expression you used? Roy Lewallen, W7EL Reg Edwards wrote: As he says, Roy's resulta are very approximate. That's mainly because he neglected proximity effect between the wires. A better approximation is obtained by incorporating an approximate expression for proximity effect. However, this makes differentiation of the loss formula with respect to wire diameter ridiculously tedious. So I found minimum loss by plotting a graph with a pocket calculator and searching for it. . . . |
"John - KD5YI" wrote Cecil Moore wrote: Reg Edwards wrote: Many years back a similar sort of calculation was done for coax. Coax does not suffer from proximity effect. It's easier to work out. The answer was 75 ohms. That's how 75 ohms became the standard comunications Ro. I vaguely remember something about efficiency Vs power handling capability being the difference in the 75 ohm standard and the 50 ohm standard. Is that right? -- ----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups ----= East and West-Coast Server Farms - Total Privacy via Encryption =---- Page 5-15 of The ARRL UHF/Microwave Experimenter's Manual says: "Consider that both power handling capability and cable losses vary with Zo. It has been shown that cable losses are minimum at a characteristic impedance on the order of 75 [Ohms], while power handling capability is maximum at a Zo of about 30 [Ohms]." (The book used the Greek symbol rather than [Ohms]) The quoted passage is in a chapter by Dr. Paul Shuch, N6TX, Professor of Electronics, Pennsylvania College of Technology. At the end of the quote, is an indication to see footnote 13 which is: "Moreno, Theodore, Microwave Transmission Design Data, Dover Publications, 1948." 73, John ============================================ It is unreliable to use ARRL and similar publications as Bibles. They are written by amateurs for amateurs and tell only a sufficient fraction of the whole story. Phrases such as "It has been shown that ..... " arise. They also refer to UHF/Microwave when LF and HF are of interest. At microwave frequencies the dielectric loss cannot be considered negligible. For minimum attenuation, air-spaced coax Zo = 75 ohms and D/d = 3.6 For solid polyethylene Zo is smaller. Confusion about the value of Zo which maximises power handling capabilty arises because coax cables have different shapes and materials to support the inner conductor. Even though the dielectric may be considered lossless its presence affects matched line loss. If my memory serves me correct, for maximum power handling I think 50 ohms refers to air-spaced coax and 30 ohms or thereabouts refers to solid polyethylene dielectric. Or it may be the other way about. It will be different again for a different dielectric permittivity. For a coax line used as a tuned circuit, eg., when short-circuited, maximum impedance at resonance occurs when Zo = 132 ohms and D/d ratio = 9.1 And just to add a little more to the confusion, whether the outer conductor is solid or braided also makes a small difference. ---- Reg, G4FGQ |
Actually, the problem as I posed it is from an engineering point of
view, assuming that a particular constraint dominated the problem...well, actually I had in mind stating it as wires that would fit inside some diameter, but that complicated it more than I wanted as an exercise for this group. Engineers should first ask what the goals and constraints are, and the space the wires fit into may be one such constraint. I suppose minimum copper cost would be the smallest wires (that could handle the required power)! A starting point for a more complete problem statement from an engineering point of view might be, "Minimize total system cost, expressed in net present value, of the system over its operating life, under a particular set of performance and installation constraints." Thanks, though, for your consideration of proximity effect. Without that, I got the same answer as Roy, and appreciated Roy's inclusion of the basis on which he made the calculation. I'd point out that for coaxial cable construction, a particular D/d minimizes the loss for a given D, and a different D/d minimizes the electric field strength for a given power and therefore maximizes the power handling capability of the line in the case where the line is voltage-limited (generally low duty cycle pulse operation), and yet another D/d minimizes the peak electric field strength for a given voltage applied to the line. So long as the dielectric loss is negligible and the dielectric is uniform, all those D/d ratios are independent of dielectric fill. The D/d which minimizes loss is close to the D/d which maximizes power handling capability of the line, if the line is power-dissipation limited, but not exactly so because it doesn't consider how the center conductor gets rid of its heat. The minimum attenuation (if the inner and outer conductors are the same smooth material and skin depth is small compared with the thickness of each) is for D/d = 3.5911, which as others have pointed out yields about 76.7 ohms with air dielectric, but if the dielectric is solid polyethylene, it's about 51 ohms. If the center conductor is smooth copper and the outer is corrugated aluminum, the minimum-attenuation D/d increases. If the dielectric is foamed polyethylene, that pushes the impedance back toward 75 ohms. Cecil...if the line is limited in power handling by its temperature rise (which is almost always the case, except for low duty cycle pulses or line construction that's very different from what we commonly use), the minimum attenuation configuration will also be the minimum net dissipation configuration, and therefore close to the optimal power handling capability. As an example of how cables we commonly use are thermally limited, consider that solid-dielectric RG-213 at 40C ambient and at 10MHz is rated at about 2kW. At 50 ohms, that's only 316 vrms for a CW signal, and RG-213 is rated for use up to 5000 vrms, which would 250 times as much power (so it better only come in little short bursts that don't overheat the line). That "power handling is maximum for Zo=30 ohms" thing is ONLY good if the line is limited by voltage breakdown, not by temperature rise! It IS useful--in radar systems, for example--but you must be careful to understand your application. Cheers, Tom |
Reg Edwards wrote:
"John - KD5YI" wrote Cecil Moore wrote: Reg Edwards wrote: Many years back a similar sort of calculation was done for coax. Coax does not suffer from proximity effect. It's easier to work out. The answer was 75 ohms. That's how 75 ohms became the standard comunications Ro. I vaguely remember something about efficiency Vs power handling capability being the difference in the 75 ohm standard and the 50 ohm standard. Is that right? -- ----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups ----= East and West-Coast Server Farms - Total Privacy via Encryption =---- Page 5-15 of The ARRL UHF/Microwave Experimenter's Manual says: "Consider that both power handling capability and cable losses vary with Zo. It has been shown that cable losses are minimum at a characteristic impedance on the order of 75 [Ohms], while power handling capability is maximum at a Zo of about 30 [Ohms]." (The book used the Greek symbol rather than [Ohms]) The quoted passage is in a chapter by Dr. Paul Shuch, N6TX, Professor of Electronics, Pennsylvania College of Technology. At the end of the quote, is an indication to see footnote 13 which is: "Moreno, Theodore, Microwave Transmission Design Data, Dover Publications, 1948." 73, John ============================================ It is unreliable to use ARRL and similar publications as Bibles. They are written by amateurs for amateurs and tell only a sufficient fraction of the whole story. Phrases such as "It has been shown that .... " arise. They also refer to UHF/Microwave when LF and HF are of interest. At microwave frequencies the dielectric loss cannot be considered negligible. For minimum attenuation, air-spaced coax Zo = 75 ohms and D/d = 3.6 For solid polyethylene Zo is smaller. Confusion about the value of Zo which maximises power handling capabilty arises because coax cables have different shapes and materials to support the inner conductor. Even though the dielectric may be considered lossless its presence affects matched line loss. If my memory serves me correct, for maximum power handling I think 50 ohms refers to air-spaced coax and 30 ohms or thereabouts refers to solid polyethylene dielectric. Or it may be the other way about. It will be different again for a different dielectric permittivity. For a coax line used as a tuned circuit, eg., when short-circuited, maximum impedance at resonance occurs when Zo = 132 ohms and D/d ratio = 9.1 And just to add a little more to the confusion, whether the outer conductor is solid or braided also makes a small difference. ---- Reg, G4FGQ Okay, Reg, then go read the material referenced by footnote 13. That's one reason I included it. Maybe that way we won't need to rely on your memory. John |
Provided skin effect is fully operative, ie., skin depth is about 1/6th wire diameter or less, proximity effect increases wire resistance by dividing normal skin-effect resistance of a single straight wire by K : K = SquareRoot( 1 - Square( D / S ) ) where D is wire diameter and S is centre-to-centre wire spacing. Note that resistance increases towards infinity as the pair of wires approach contact with each other. This is confirmed by precision measurements. To minimise line attenuation for any given wire spacing, maximise U with respect to D : U = D * InvCosh( S / D ) * SquareRoot( 1 - Square( D / S ) ) . ----- Reg, G4FGQ |
John - KD5YI wrote: .... Okay, Reg, then go read the material referenced by footnote 13. That's one reason I included it. Maybe that way we won't need to rely on your memory. The confusion comes (in the quoting of the texts) because of a failure to consider that there are two different mechanisms that can limit the power handling capability of the line. One is power dissipation (temperature rise), and the other is voltage breakdown. Clearly the minimum power dissipation for a given input power and matched line occurs where the line attenuation is minimum. But if you make the inner conductor slightly larger, it may be able to get rid of heat enough better (for a given line construction) that the inner conductor temperature rise is slightly lower, even though the power dissipation is slightly higher. I would expect, though, that the optimal construction in most circumstances would result in an impedance only marginally lower than the minimum attenuation case, and the improvement would be a very small one. You'd have to convince me it was really important to get me to worry about it beyond just minimizing attenuation. If it's voltage breakdown that limits the line power handling capability, the air-insulated impedance of the line will be at a D/d that results in about 30 ohms impedance for air-dielectric line, and ..66 times as much for solid polyethylene line. And if it's maximum voltage-handling you want, the D/d results in somewhere around 50 ohms with air-insulated line, about 33 ohms with solid poly, if memory serves. I could look it up if it's really important. Generally in ham applications, (reasonably well matched) lines will be power dissipation limited, not voltage limited. Cheers, Tom |
From LF to VHF it is ALWAYS power dissipated in conductor resistance which limits the power handling capability of the line. Voltage has nothing to do with it. Above VHF dielectric loss becomes be the limitation. Consideration of ambient temperature is vital. Are you located in Alaska at midnight in mid-winter? Or are you in the New Mexico desert in July, at noon. It makes hell of a difference? With coax everything depends on the temperture softening point of polyethylene and on the the longer-term temperature deterioration (hardening, cracking, brittleness) of the PVC sheath. Is the cable embedded in an asbestos insulated brick wall or is it suspended in free air with a breeze in the shade? Or in sunlight? The power rating data provided by manufacturers for amateur grade coaxial cables is useless nonsense. From inspection of manufacturers' tables (watts) it can be deduced their ratings are based on the melting point of polyethylene. Salesmen's blurbs, no doubt plagiarised in ARRL publications, sound very good in order to sell the stuff. To gain an elementary understanding of what it's all about, download in a few seconds, easy to use, practical application, small program "COAXRATE" from website below and run immediately. (Not zipped up). Program "COAXRATE". ---- .................................................. .......... Regards from Reg, G4FGQ For Free Radio Design Software go to http://www.btinternet.com/~g4fgq.regp .................................................. .......... |
Reg Edwards wrote:
From LF to VHF it is ALWAYS power dissipated in conductor resistance which limits the power handling capability of the line. Voltage has nothing to do with it. What if it arcs? -- 73, Cecil http://www.qsl.net/w5dxp ----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups ----= East and West-Coast Server Farms - Total Privacy via Encryption =---- |
What if it arcs? -- ================= It shows the voltage rating has been exceeded. |
Reg wrote:
"From LF to VHF it is ALWAYS power dissipated in conductor resistance which limits the power handling capability of the line. Voltage has nothing to do with it. Above VHF dielectric loss becomes be the limitation. " Always? Hardly. Transmission of pulses with low duty cycle will get you to voltage-limited operation pretty quickly. Transmission of power to a high-resistance load where the line is a very small fraction of a wavelength long may get you into voltage-limited operation. Those perhaps aren't typical ham applications, but they do happen in practice. Also, though the cable itself may not have trouble with the applied voltage, the connectors at the ends may. They're generally rated for much lower voltage than the line itself. Also, for the small-diameter (nom. RG-58 size) cables I've been using lately, conductor loss exceeds dielectric loss out past 10GHz. YYMV. Cheers, Tom |
Reg Edwards wrote:
What if it arcs? It shows the voltage rating has been exceeded. But, but, but, Reg, you said "voltage has nothing to do with it." :-) -- 73, Cecil http://www.qsl.net/w5dxp ----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 100,000 Newsgroups ---= East/West-Coast Server Farms - Total Privacy via Encryption =--- |
K7ITM wrote:
Also, though the cable itself may not have trouble with the applied voltage, the connectors at the ends may. They're generally rated for much lower voltage than the line itself. Yep, during duststorms and thunderstorms, the connectors arc. Arcing at the coax connectors of my IC-745, IC-725, IC-706, and IC-756PRO has never seemed to injure any of them. Is that just luck or are they that well protected? -- 73, Cecil http://www.qsl.net/w5dxp ----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 100,000 Newsgroups ---= East/West-Coast Server Farms - Total Privacy via Encryption =--- |
What if it arcs? It shows the voltage rating has been exceeded. But, but, but, Reg, you said "voltage has nothing to do with it." :-) ============================== I'm very sorry Cec, but in future I shall have to make a modest charge for answering your questions. In advance if you wouldn't mind. |
Provided skin effect is fully operative, ie., skin depth is about 1/6th wire diameter or less, proximity effect increases wire resistance by dividing normal skin-effect resistance of a single straight wire by K : K = SquareRoot( 1 - Square( D / S ) ) where D is wire diameter and S is centre-to-centre wire spacing. Note that resistance increases towards infinity as the pair of wires approach contact with each other. This is confirmed by precision measurements. To minimise line attenuation for any given wire spacing, maximise U with respect to D : U = D * InvCosh( S / D ) * SquareRoot( 1 - Square( D / S ) ) . ==================================== Roy, having given a little more thought to it, I think that by differentiating U with respect to D and equating dU/dD to zero, things will then simplify and the value of the ratio S /D, and hence Zo, will be obtained directly. If you still have enough enthusiasm I leave it to you to perform the differentiation. ---- Reg. |