Home |
Search |
Today's Posts |
#6
![]() |
|||
|
|||
![]()
The nominal impedance of a 40 m dipole, at 30 ft above an average ground, is
4700 + j0. There may be some inductive or capacitive reactance present -- depending on the exact length of the antenna -- but it will not effect the transmission line losses significantly. 100 ft of RG 58 exhibits a total line loss of about 13 dB when terminated with the above impedance. i.e. 100 W in gives 5 W radiated. For the above analysis I used NEC 2 for the antenna model, and ARRL's TLA for the transmission line loss. Regards, Frank "Gary" wrote in message ... If, just for example I'm loading 20 meters into a 40 meter dipole what's the formula for determining the resultant SWR ? And then what's the formula for determining what my losses would be between say feeding the 40 meter dipole with 100' of RG-58 vs 100' of 450 ohm ladder line on 20 meters. Of course the 450 ohm twinlead would screw up the (likely) close match between the dipole and the RG-58 on 40 meters. Maybe this requires some kind of antenna modeling program ? Thanks in advance. Gary |