On Sat, 10 Dec 2005 21:50:15 GMT, Owen Duffy wrote:
[good stuff snipped] | |Someone will probably suggest that LDF6-50 (32mm (1.25") hardline) |could achieve 0.3dB loss, but could you afford it, would it be good |value? I wasn't going to go that far, and I realize it's probably not common in ZL but I've bought lengths of LDF5-50 at ham flea markets. The last purchase, claimed to be about 10 meters worth, but by my estimation at least twice that long, and new and unused, cost me $10 U.S. Most of this stuff is leftover or removed from commercial two-way or cell phone use and shows up all of the time. LDF4-50 is even more common. I often buy short pieces that have been cut down, just for the connectors that are still on one end. I find it curious that Andrew cable is seen so often at these events and yet I've -never- even seen a piece of Davis cable, dispite the claims that miles of it are in commercial use. |
#2
![]() |
|||
|
|||
![]()
On Sun, 11 Dec 2005 05:39:27 +0000, Wes Stewart *n7ws*@ yahoo.com
wrote: I wasn't going to go that far, and I realize it's probably not common in ZL but I've bought lengths of LDF5-50 at ham flea markets. The last purchase, claimed to be about 10 meters worth, but by my estimation at least twice that long, and new and unused, cost me $10 U.S. Most of this stuff is leftover or removed from commercial two-way or cell phone use and shows up all of the time. LDF4-50 is even more common. I often buy short pieces that have been cut down, just for the connectors that are still on one end. I find it curious that Andrew cable is seen so often at these events and yet I've -never- even seen a piece of Davis cable, dispite the claims that miles of it are in commercial use. I agree with Ian's comments, the larger sizes are often available here as they are less attractive to hams. But if you buy 3 or 4 lengths of LDF5 or LDF6 and use connectors to join them, you will run into big $ unless the connectors come very cheap. Andrews has some braid+foil / foam coax, and they perform roughly similarly to LMR400, BuryFlex and 9913. To my mind LDF4-50 would be acceptable in this configuration, and the great advantage is that if water gets in somewhere, it doesn't wick right down the cable. I haven't handled BuryFlex, and I saw the claim it is waterproof, but I suspect it is not as waterproof as Heliax type cable where the closed cell foam dielectric is bonded to the inner and outer conductor with an adhesive, and there is no braid to form a natural wick. I am in the throes of replacing feedline on a HF dipole to repair damage by birds. The birds don't seem to eat PE irrigation tube, so I have fitted RG6 with a W2DU style balun inside 13mm PE tube to defeat the birds. The birds have attacked the LDF4-50 on the VHF/UHF antennas, but even if they make a hole in the copper, it doesn't seem to affect cable performance measurably, probably because the water can't travel up and down the cable from the hole. Still, parts of ZL have Keas, and they will eat anything, especially rubber or plastic! So I feel for our ZL friends running coax over 60m of ground. BTW, I added BuryFlex to my online line loss calculator, 9913 and C2FP were already there. I still like the open line option, but it will be real important to use effective baluns to adequately ensure balance. It used to be common commercial practice when HF Radio was used more widely for international telephony / telegraphy. Owen -- |
#3
![]() |
|||
|
|||
![]()
On Sun, 11 Dec 2005 06:06:08 GMT, Owen Duffy wrote:
On Sun, 11 Dec 2005 05:39:27 +0000, Wes Stewart *n7ws*@ yahoo.com wrote: I wasn't going to go that far, and I realize it's probably not common in ZL but I've bought lengths of LDF5-50 at ham flea markets. The last purchase, claimed to be about 10 meters worth, but by my estimation at least twice that long, and new and unused, cost me $10 U.S. Most of this stuff is leftover or removed from commercial two-way or cell phone use and shows up all of the time. LDF4-50 is even more common. I often buy short pieces that have been cut down, just for the connectors that are still on one end. I find it curious that Andrew cable is seen so often at these events and yet I've -never- even seen a piece of Davis cable, dispite the claims that miles of it are in commercial use. I agree with Ian's comments, the larger sizes are often available here as they are less attractive to hams. But if you buy 3 or 4 lengths of LDF5 or LDF6 and use connectors to join them, you will run into big $ unless the connectors come very cheap. I have a ham friend who uses long runs of coax to his several towers. He is a big gun on 80 and 160 meters, so this mainly applies at m-f to h-f. He uses a lot of LDF5-50 that he obtains in shorter pieces. His technique, as he briefly described it to me, is to -not- use connectors but splice the lengths directly. The center conductor on these cables is hollow, so he inserts a short length of brass or copper into the ID and solders it in place. I don't know whether he adds any insulation next or not, but I would envision injecting some low-expansion spray foam later. He then wraps the outer conductor with brass or copper foil and solders this in place. (Here is where I would inject the foam.) This is then wrapped with tape for protection. I would use a double layer of #27 3M tape with an overwrap of plastic electrical tape. To strengthen the joint mechanically, he straps on a length of steel angle using stainless hose clamps. For lines on or in the ground this stays in place. For runs up the tower, after the line is in place, strapping to the tower is sufficient support. |
#4
![]() |
|||
|
|||
![]()
Wes Stewart wrote:
I agree with Ian's comments, the larger sizes [of hardline] are often available here as they are less attractive to hams. But if you buy 3 or 4 lengths of LDF5 or LDF6 and use connectors to join them, you will run into big $ unless the connectors come very cheap. Generally the same applies to the connectors as to the cable itself - the surplus prices are much lower than the new prices, and larger sizes may even be cheaper. However, I do agree that you don't need connectors in order to make a splice in a static installation. This technique makes a solid splice, with a low SWR even at 432MHz: I have a ham friend who uses long runs of coax to his several towers. He is a big gun on 80 and 160 meters, so this mainly applies at m-f to h-f. He uses a lot of LDF5-50 that he obtains in shorter pieces. His technique, as he briefly described it to me, is to -not- use connectors but splice the lengths directly. The center conductor on these cables is hollow, so he inserts a short length of brass or copper into the ID and solders it in place. And for the smaller sizes with a solid center conductor, splice with a short length of hobby brass tuning over the outside. I don't know whether he adds any insulation next or not, but I would envision injecting some low-expansion spray foam later. The foam is mostly empty space anyway, so even at UHF an inch or so will hardly be missed. He then wraps the outer conductor with brass or copper foil and solders this in place. In some sizes, a slit length of copper water pipe can work too. This is then wrapped with tape for protection. I would use a double layer of #27 3M tape with an overwrap of plastic electrical tape. To strengthen the joint mechanically, he straps on a length of steel angle using stainless hose clamps. Yup, all of the above. It works fine. The overall conclusion is that - both physically and financially - large hardline is nowhere near as 'hard' as most people think. BTW, I do have one genuine Andrew splice for LDF5-50, which I'm hoarding for some undefined future need. It's truly a thing of wonder... especially the insert that connects the two hollow center conductors. One end screws in with a tapered variable-pitch thread, so the other end has to have a tapered variable-pitch *left-hand* thread. Only a CNC programmer with far too much time on his hands could have thought of that. -- 73 from Ian GM3SEK 'In Practice' columnist for RadCom (RSGB) http://www.ifwtech.co.uk/g3sek |
#5
![]() |
|||
|
|||
![]()
Wes Stewart said:
I find it curious that Andrew cable is seen so often at these events and yet I've -never- even seen a piece of Davis cable, dispite the claims that miles of it are in commercial use. It might be that the BuryFlex is still in use and has not been removed from service as the Heliax you cite has been. After all Davis BuryFlex 9914 does have a warranted - 20 year service life - Is there any other coax with such a warranty? --- Charlie |
#6
![]() |
|||
|
|||
![]() Charlie wrote: Wes Stewart said: I find it curious that Andrew cable is seen so often at these events and yet I've -never- even seen a piece of Davis cable, dispite the claims that miles of it are in commercial use. It might be that the BuryFlex is still in use and has not been removed from service as the Heliax you cite has been. After all Davis BuryFlex 9914 does have a warranted - 20 year service life - Is there any other coax with such a warranty? --- Charlie I don't seem to be able to find any mention of a warranty on their site - can you point it out for me? Dave |
#7
![]() |
|||
|
|||
![]()
At the bottom of this page the ** footnote
1. http://www.davisrf.com/ham1/coax.htm "note that Bury-Flex has a 20+ year abrasive resistant jacket of PE" -- Charlie "Dave Holford" wrote in message ... Charlie wrote: Wes Stewart said: I find it curious that Andrew cable is seen so often at these events and yet I've -never- even seen a piece of Davis cable, dispite the claims that miles of it are in commercial use. It might be that the BuryFlex is still in use and has not been removed from service as the Heliax you cite has been. After all Davis BuryFlex 9914 does have a warranted - 20 year service life - Is there any other coax with such a warranty? --- Charlie I don't seem to be able to find any mention of a warranty on their site - can you point it out for me? Dave |
#8
![]() |
|||
|
|||
![]()
That's a guarantee??
Dave Charlie wrote: At the bottom of this page the ** footnote 1. http://www.davisrf.com/ham1/coax.htm "note that Bury-Flex has a 20+ year abrasive resistant jacket of PE" -- Charlie "Dave Holford" wrote in message ... Charlie wrote: Wes Stewart said: I find it curious that Andrew cable is seen so often at these events and yet I've -never- even seen a piece of Davis cable, dispite the claims that miles of it are in commercial use. It might be that the BuryFlex is still in use and has not been removed from service as the Heliax you cite has been. After all Davis BuryFlex 9914 does have a warranted - 20 year service life - Is there any other coax with such a warranty? --- Charlie I don't seem to be able to find any mention of a warranty on their site - can you point it out for me? Dave |
#9
![]() |
|||
|
|||
![]()
I don't recall -anyone- using the word "guarantee". Please post that
reference.....TY -- Charlie "Dave Holford" wrote in message ... That's a guarantee?? Dave Charlie wrote: At the bottom of this page the ** footnote 1. http://www.davisrf.com/ham1/coax.htm "note that Bury-Flex has a 20+ year abrasive resistant jacket of PE" -- Charlie "Dave Holford" wrote in message ... Charlie wrote: Wes Stewart said: I find it curious that Andrew cable is seen so often at these events and yet I've -never- even seen a piece of Davis cable, dispite the claims that miles of it are in commercial use. It might be that the BuryFlex is still in use and has not been removed from service as the Heliax you cite has been. After all Davis BuryFlex 9914 does have a warranted - 20 year service life - Is there any other coax with such a warranty? --- Charlie I don't seem to be able to find any mention of a warranty on their site - can you point it out for me? Dave |
#10
![]() |
|||
|
|||
![]()
Ah yes -"warranted" - my apology!
"After all Davis BuryFlex 9914 does have a warranted - 20 year service life" Dave Charlie wrote: I don't recall -anyone- using the word "guarantee". Please post that reference.....TY -- Charlie "Dave Holford" wrote in message ... That's a guarantee?? Dave Charlie wrote: At the bottom of this page the ** footnote 1. http://www.davisrf.com/ham1/coax.htm "note that Bury-Flex has a 20+ year abrasive resistant jacket of PE" -- Charlie "Dave Holford" wrote in message ... Charlie wrote: Wes Stewart said: I find it curious that Andrew cable is seen so often at these events and yet I've -never- even seen a piece of Davis cable, dispite the claims that miles of it are in commercial use. It might be that the BuryFlex is still in use and has not been removed from service as the Heliax you cite has been. After all Davis BuryFlex 9914 does have a warranted - 20 year service life - Is there any other coax with such a warranty? --- Charlie I don't seem to be able to find any mention of a warranty on their site - can you point it out for me? Dave |
Reply |
|
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
A Coax experiment | Shortwave | |||
The "TRICK" to TV 'type' Coax Cable [Shielded] SWL Loop Antennas {RHF} | Antenna | |||
The "TRICK" to TV 'type' Coax Cable [Shielded] SWL Loop Antennas {RHF} | Shortwave | |||
Poor quality low + High TV channels? How much dB in Preamp? | Antenna | |||
Poor quality low + High TV channels? How much dB in Preamp? | Shortwave |