#1
![]() |
|||
|
|||
![]()
Hello:
Anyone have any thoughts on (hopefully not experiences) whether putting a loop of, e.g. 1 foot in diameter, on a coax run from an outdoor receive-only antenna has any merit as far as helping any emf lightning induced pulses from traveling into a house ? Have heard about this, but it's hard to believe it would actually do anything in practice. But,... ? B. |
#2
![]() |
|||
|
|||
![]()
All the grounding info I have seen mentions no sharp bends, or any bends
if you can help it when bonding tower legs, etc to ground rods or ground rings as it raises the impedance to the ground connection. I can see a loop in the coax being beneficial as a supplement to a ground system, but definitely not as the only precaution. It takes a well designed lightning ground system to take a direct hit without any damage and I have never seen one in a residential setting. I know several mountain top repeater sites that take hits all the time with no apparent damage but the entire site including the building, tower and electrical system were designed from the start with lightning in mind. Bob Robert11 wrote: Hello: Anyone have any thoughts on (hopefully not experiences) whether putting a loop of, e.g. 1 foot in diameter, on a coax run from an outdoor receive-only antenna has any merit as far as helping any emf lightning induced pulses from traveling into a house ? Have heard about this, but it's hard to believe it would actually do anything in practice. But,... ? B. |
#3
![]() |
|||
|
|||
![]()
Do you think a loop will stop what three miles of sky could not?
Effective protection is not about stopping a transient. That does not work and is they myth even used to promote plug-in protectors. A most trivial earth ground is a massive improvement in protection. That incoming wire must be earthed - directly or through a protector - before entering the building. That simplest earthing is many times more effective than 100 loops. Effective for direct strkes - which means induced trasnients would be made irrelevant. The US Forestry Service has documented that most direct strikes to trees do not leave appreciable indication. Even a standard household earth ground in conductive soil will provide protection from most lightning strikes. Then we enhance that earthing for other, more violent and less frequent direct strikes. Quality of earthing determines how many direct strikes will be earthed without damage. Even some earthng to a single point is a massive improvement in transistor protection. But the loop is about as useful as bad science fiction. For loop to be effective, then loop also must seriously degrade radio reception. How many reasons why that loop is useless? Five? Robert11 wrote: Hello: Anyone have any thoughts on (hopefully not experiences) whether putting a loop of, e.g. 1 foot in diameter, on a coax run from an outdoor receive-only antenna has any merit as far as helping any emf lightning induced pulses from traveling into a house ? Have heard about this, but it's hard to believe it would actually do anything in practice. But,... ? B. |
#4
![]() |
|||
|
|||
![]()
W_Tom wrote:
"Do you think the loop will stop what three miles of sky could not?" Depends on what kind of loops and how many. I`ve worked in several broadcast stations that often got struck by lightning. Their towers were the tallest things around. None of these stations got significant damage from lightning. In addition, none of the station equipment powered from the mains or appliances plugged into the mains at the station ever was damaged. All these stations used tower lighting chokes, one coil for each tower lighting wire including the neutral going up the tower. Three wires, beacon, side lights, and neutral were usually accommodated with tower lighting chokes. Their primary function is to avoid sapping any of the r-f energy from the tower. Another benefit is that the chokes reject lightning too. They are substantial and all turns are wound side by side (trifiler?) around a large ceramic coil form. The wire is large enough to easily handle the load current. I never worked at a station that used Austin tower lighting transformers instead of chokes, but I`ve seen enough of them to suppose they must isolate about as well as chokes do. One station I worked in had an FM antenna atop one if its AM broadcast towers. Its FM coax was coiled at ground level to isolate the AM r-f and it rejected lightning too. So, if you have enough of the right turns the choke does effectively reject lightning. Inductance is proportional to the size of the coil. Best regards, Richard Harrison, KB5WZI |
#5
![]() |
|||
|
|||
![]()
The OP asked:
Anyone have any thoughts on (hopefully not experiences) whether putting a loop of, e.g. 1 foot in diameter, on a coax run from an outdoor receive-only antenna One turn of coax is all but not a choke. Then the loop is not located after a better path to earth. It is just a coax loop 1 foot diameter that will somehow stop lightning - without some other path for lightning to seek earth. Somehow it will block lightning and while not impeding radio reception. How many henries stops - not diverts - stops lightning? Richard Harrison has previously described this choke as part of a system where lightning also has a conductive path to earth. Only with earthing is lightning further discouraged - diverted - by a choke. Choke can only discourage lightning when lightning has a significantly more conductive path to earth elsewhere. A 1 foot diameter loop of coax does not even begin to accomplish what that choke would, nor is it defined as part of a system that includes earthing. Just some of maybe five reasons why that single coax loop does nothing useful. A coax loop is really not a choke. A choke by itself does not even stop what three miles of sky could not. But a choke can be part of a system that diverts lightning to some other earthing path. Without earth ground, even a choke would not be very effective. And a one loop of coax does not even perform as a choke would. So many reasons why that coax loops does nothing effective. Then the numbers. How many henries does a single 1 foot loop of coax cable create? Ballpark - maybe 1 microhenry. How does a microhenry stop or block lightning? Would inductance existing in an uncoiled coax wire actually do more to stop lightning? A significant difference exists between stopping and diverting. Richard Harrison wrote: w_tom wrote: "Do you think the loop will stop what three miles of sky could not?" Depends on what kind of loops and how many. I`ve worked in several broadcast stations that often got struck by lightning. Their towers were the tallest things around. None of these stations got significant damage from lightning. In addition, none of the station equipment powered from the mains or appliances plugged into the mains at the station ever was damaged. All these stations used tower lighting chokes, one coil for each tower lighting wire including the neutral going up the tower. Three wires, beacon, side lights, and neutral were usually accommodated with tower lighting chokes. Their primary function is to avoid sapping any of the r-f energy from the tower. Another benefit is that the chokes reject lightning too. They are substantial and all turns are wound side by side (trifiler?) around a large ceramic coil form. The wire is large enough to easily handle the load current. I never worked at a station that used Austin tower lighting transformers instead of chokes, but I`ve seen enough of them to suppose they must isolate about as well as chokes do. One station I worked in had an FM antenna atop one if its AM broadcast towers. Its FM coax was coiled at ground level to isolate the AM r-f and it rejected lightning too. So, if you have enough of the right turns the choke does effectively reject lightning. Inductance is proportional to the size of the coil. Best regards, Richard Harrison, KB5WZI |
#6
![]() |
|||
|
|||
![]()
W_Tom wrote:
"How does a microhenry stop or divert lightning?" Alone, not effectively. I think "driploops" are almost usless in lightning protection. W_Tom is right. You need to make a path unattractive to protect and divert the lightning to an easier path to earth. Best regards, Richard Harrison, KB5WZI |
#7
![]() |
|||
|
|||
![]()
That's right - a bolt of lightning comes streaking across several miles of
dry air, finds the antenna with no problem, then upon seeing the loop, ducks back into the ground. But at least the loop will make the rain drip outside. It not useless. "w_tom" wrote in message oups.com... Do you think a loop will stop what three miles of sky could not? Effective protection is not about stopping a transient. That does not work and is they myth even used to promote plug-in protectors. A most trivial earth ground is a massive improvement in protection. That incoming wire must be earthed - directly or through a protector - before entering the building. That simplest earthing is many times more effective than 100 loops. Effective for direct strkes - which means induced trasnients would be made irrelevant. The US Forestry Service has documented that most direct strikes to trees do not leave appreciable indication. Even a standard household earth ground in conductive soil will provide protection from most lightning strikes. Then we enhance that earthing for other, more violent and less frequent direct strikes. Quality of earthing determines how many direct strikes will be earthed without damage. Even some earthng to a single point is a massive improvement in transistor protection. But the loop is about as useful as bad science fiction. For loop to be effective, then loop also must seriously degrade radio reception. How many reasons why that loop is useless? Five? Robert11 wrote: Hello: Anyone have any thoughts on (hopefully not experiences) whether putting a loop of, e.g. 1 foot in diameter, on a coax run from an outdoor receive-only antenna has any merit as far as helping any emf lightning induced pulses from traveling into a house ? Have heard about this, but it's hard to believe it would actually do anything in practice. But,... ? B. |
#8
![]() |
|||
|
|||
![]()
In article ,
"Hal Rosser" wrote: That's right - a bolt of lightning comes streaking across several miles of dry air, finds the antenna with no problem, then upon seeing the loop, ducks back into the ground. But at least the loop will make the rain drip outside. It not useless. I've read that most of the lightning starts at the ground first and reaches into the sky to find the other end. "w_tom" wrote in message oups.com... Do you think a loop will stop what three miles of sky could not? Effective protection is not about stopping a transient. That does not work and is they myth even used to promote plug-in protectors. A most trivial earth ground is a massive improvement in protection. That incoming wire must be earthed - directly or through a protector - before entering the building. That simplest earthing is many times more effective than 100 loops. Effective for direct strkes - which means induced trasnients would be made irrelevant. The US Forestry Service has documented that most direct strikes to trees do not leave appreciable indication. Even a standard household earth ground in conductive soil will provide protection from most lightning strikes. Then we enhance that earthing for other, more violent and less frequent direct strikes. Quality of earthing determines how many direct strikes will be earthed without damage. Even some earthng to a single point is a massive improvement in transistor protection. But the loop is about as useful as bad science fiction. For loop to be effective, then loop also must seriously degrade radio reception. How many reasons why that loop is useless? Five? Robert11 wrote: Hello: Anyone have any thoughts on (hopefully not experiences) whether putting a loop of, e.g. 1 foot in diameter, on a coax run from an outdoor receive-only antenna has any merit as far as helping any emf lightning induced pulses from traveling into a house ? Have heard about this, but it's hard to believe it would actually do anything in practice. But,... ? B. |
#9
![]() |
|||
|
|||
![]()
Robert11 wrote:
Hello: Anyone have any thoughts on (hopefully not experiences) whether putting a loop of, e.g. 1 foot in diameter, on a coax run from an outdoor receive-only antenna has any merit as far as helping any emf lightning induced pulses from traveling into a house ? Have heard about this, but it's hard to believe it would actually do anything in practice. But,... ? B. you been hanging out on 11 meters? |
#10
![]() |
|||
|
|||
![]()
stananger wrote:
Robert11 wrote: Anyone have any thoughts on (hopefully not experiences) whether putting a loop of, e.g. 1 foot in diameter, on a coax run from an outdoor receive-only antenna has any merit as far as helping any emf lightning induced pulses from traveling into a house ? you been hanging out on 11 meters? Reminds me of what I once told my secretary back in the 70's. Our lab soldering irons were simple AC devices with standard AC cords attached. We tied a half-hitch knot in them and used that loop to hang them on nails on the wall. I was at the bench one day and my secretary asked me what the knot was for. I told her that by tightening the knot, I could regulate the flow of electrons and thus control the temperature of the soldering iron. Later that night, over drinks at Charlie Brown's, she and I had a good laugh about that. -- 73, Cecil http://www.qsl.net/w5dxp |
Reply |
|
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Building a 'simple' Attic Loop Antenna = Not So Simple ! | Shortwave | |||
FYI: NOAA Lightning Safety Awareness Week | Policy | |||
Antenna experiment, coax shielded loop | Shortwave | |||
The "TRICK" to TV 'type' Coax Cable [Shielded] SWL Loop Antennas {RHF} | Antenna | |||
The "TRICK" to TV 'type' Coax Cable [Shielded] SWL Loop Antennas {RHF} | Shortwave |