Velocity Factor (VP) for RG8X?
Is 78% the correct velocity factor for RG8X coax?
|
Velocity Factor (VP) for RG8X?
that is what is listed in the belden catalog
"AK" wrote in message news:KRUZf.88176$oL.627@attbi_s71... Is 78% the correct velocity factor for RG8X coax? |
Velocity Factor (VP) for RG8X?
Thanks Dave. The only Belden catalog info I could find on-line didn't list
the VP. Is there a link for full Belden info you could give me? AK |
Velocity Factor (VP) for RG8X?
My experience is that the velocity factor of foam dielectric cable like
RG8X varies considerably from batch to batch and manufacturer to manufacturer. Apparently they have poor control over the foam density in the manufacturing process. For any application where it really matters, you really have to measure it for the particular piece of cable you'll be using. Roy Lewallen, W7EL AK wrote: Is 78% the correct velocity factor for RG8X coax? |
Velocity Factor (VP) for RG8X?
i have a paper catalog, don't know about on-line links for them.
"AK" wrote in message news:eWUZf.88181$oL.84498@attbi_s71... Thanks Dave. The only Belden catalog info I could find on-line didn't list the VP. Is there a link for full Belden info you could give me? AK |
Velocity Factor (VP) for RG8X?
i have a paper catalog, don't know about on-line links for them.
All the info in your paper catalog is available online at belden.com .. All the original poster has to do is click on " Catalog " , then the " e-catalog " and then type in his cable type, ( RG8X) in the search window. Belden will then display the one type of RG8X cable they make, their number 9258. If one then clicks on this number, the complete specs will be displayed. Just scroll down the specs and one will find the velocity factor of Belden's RG8X is 82%. http://bwccat.belden.com/ecat/jsp/In...1=undefined&P2 =undefined&P3=undefined&P4=undefined&P5=undefined& P6=undefined Ed K7AAT |
Velocity Factor (VP) for RG8X?
My experience is that the velocity factor of foam dielectric cable
like RG8X varies considerably from batch to batch and manufacturer to manufacturer. Apparently they have poor control over the foam density in the manufacturing process. For any application where it really matters, you really have to measure it for the particular piece of cable you'll be using. Roy Lewallen, W7EL ==================================== And the same applies to impedance Zo and attenuation. ---- Reg. |
Velocity Factor (VP) for RG8X?
Reg Edwards wrote:
And the same applies to impedance Zo and attenuation. How much could the Z0 vary for "50 ohm" coax? -- 73, Cecil http://www.qsl.net/w5dxp |
Velocity Factor (VP) for RG8X?
Roy is right. You must meaure your cable to be sure.
The stuff I have now calculates to .73 using a regular MFJ analyzer. Roy Lewallen wrote: My experience is that the velocity factor of foam dielectric cable like RG8X varies considerably from batch to batch and manufacturer to manufacturer. Apparently they have poor control over the foam density in the manufacturing process. For any application where it really matters, you really have to measure it for the particular piece of cable you'll be using. Roy Lewallen, W7EL AK wrote: Is 78% the correct velocity factor for RG8X coax? |
Velocity Factor (VP) for RG8X?
"Cecil Moore" wrote in message . com... Reg Edwards wrote: And the same applies to impedance Zo and attenuation. How much could the Z0 vary for "50 ohm" coax? -- ================================= For coax, Zo = 60 * VF * Ln( D / d ) So Zo varies as VF varies. You'll just have to measure VF or Zo. Similar for attenuation. ---- Reg. |