w9gb wrote:
Make sure that ICM did not quote you for: 1. A high precision crystal (they may do that for this one since it determines IF) 2. Entire L6 assembly ( Replacing the entire L6 shield can -- as described in W1FSN NC-300 revision - page 18 of 18) ftp://bama.sbc.edu/downloads/nationa...sn/300fsn.djvu ICM likely has the documentation for that entire mod -- and may be referencing that -- and may be more than you want. w9gb I was interested in doing the mods as outlined in the above referenced field service notes. I had downloaded the info from bama a long time ago and am just now starting to get the rx into working codition. Xtals are used in upper/lower side band select which replaces L6 assembly. I a surprised to learn that ICM is able to research the NC-300 that well. These guys must be good! |