Ian Smith August 13th 07 06:43 PM

Heathkit IG-42
 
Hi
I have a Heathkit IG-42 signal generator. The RF choke coils on the
power supply need replacing,however I can find no reference in the
manual as to their value. Can someone help with values, substitutions
or are the even necessary.

Many thanks
Ian

K3HVG[_2_] August 13th 07 08:00 PM

Heathkit IG-42
 
Ian Smith wrote:
Hi
I have a Heathkit IG-42 signal generator. The RF choke coils on the
power supply need replacing,however I can find no reference in the
manual as to their value. Can someone help with values, substitutions
or are the even necessary.

Many thanks
Ian

If you're referring to the two line filter chokes, they are to
prevent/reduce RF leakage from the generator onto the AC line. You can
wind new ones using about 18T of #16 wire on a 1/4" air core. Also, you
could simply bypass the internal chokes and use one of the new,
sandwich-type RFI/EMI toroid line filters, externally on the line cord.
I'm curious as to how the originals went bad?


Scott Dorsey August 13th 07 10:27 PM

Heathkit IG-42
 
Ian Smith wrote:
I have a Heathkit IG-42 signal generator. The RF choke coils on the
power supply need replacing,however I can find no reference in the
manual as to their value. Can someone help with values, substitutions
or are the even necessary.


What makes you think they went bad? As I recall, they are made with huge
wire, maybe 18 ga. How can that fail?

If it really DID fail, try replacing it with a Corcom EMI filter. Much
more effective than the original filters, and it meets current leakage
ratings (which the original bypass caps probably do not).
--scott
--
"C'est un Nagra. C'est suisse, et tres, tres precis."