I'm working on yet another Valiant I. This one has the Johnson SSB
adaptor wiring modification kit installed (if that is an issue?). All appears to be well, RF out, etc. but I have a question regarding one of the meter readings. In the oscillator position (6CL6 buffer cath. current), I get a continuous 10ma reading, key up (idle current, if you will). Key down, I get an expected swing upward, the keyer circuit appears to work OK, and the unit transmits with nothing untoward happening. On the other two Valiants I have, there is no measurable current in the osc. meter position, key up. I've checked virtually all components in/around the buffer and keyer circuits with no problems detected. The only issue is that the derived grid bias on the buffer is -3v vice the -5v called for in the book. That may be the reason the buffer is idling at a higher current... but why? What is not provided by Johnson is a re-drawn schematic after the somewhat extensive re-wire job for the SSB adaptor. I could just ignore the issue as the 6CL6 is still well within its operating range. Maybe someone else has had this come up and/or its normal after the mod has been done? The mod book makes no mention. Thanks for any insights. de K3HVG |