On Tue, 15 Jan 2008 21:26:15 -0800, None wrote:
I just got my B&K 747 tube tester back from professional calibration and service at CTech Electronics, and I'm now very careful in how I use it, so as not to damage anything like I aparently did before. My question is this: I now hit the 'shorts' button first thing after the filament is lit. If it lights, I pull the tube and do NOT hit the 'test' button. But is there ever a circumstance where a 'good' tube will cause the shorts light to light? I ask because I had some 6146s a while ago that would light the 'shorts' light up, but tested far into the 'good' range scale. Any input would be helpful, Thanks Dave WB7AWK On my tube tester there are some settings on some tubes that'll cause a short indication, but they're listed in the manual (and presumably you don't do an emission test across those terminals). -- Tim Wescott Control systems and communications consulting http://www.wescottdesign.com Need to learn how to apply control theory in your embedded system? "Applied Control Theory for Embedded Systems" by Tim Wescott Elsevier/Newnes, http://www.wescottdesign.com/actfes/actfes.html |