I just finished repairing an SB-301 receiver. It works well, however,
I can’t reliably calibrate the dial. For example, if I zero the dial at, say, 3.5 Mhz using the internal 100 Khz crystal oscillator, the needle is about 4 Khz too high at 3.6, 3.7, 3.8 and 3.8 Mhz, but is again zeroed at 4.0 Mhz. Is this normal behavior for linear master oscillators (LMOs)? NOTE: This LMO needed to be repaired. Two of its tabbed slip rings on the tuning shaft were “glued” together (hardened grease) and its capacitor plates moved beyond the fully meshed position on the low end of the tuning range. Anyhow, I removed and cleaned the slip rings and adjusted the rotation offset of the tuning capacitor. I’m now left wondering if, out of necessity, I fouled up the LMO’s calibration. This is a manageable shortcoming, as I can calibrate to the nearest 100 Khz mark. Nevertheless, I’m curious if such variability is normal. -Dave Drumheller, K3WQ |