RadioBanter

RadioBanter (https://www.radiobanter.com/)
-   Boatanchors (https://www.radiobanter.com/boatanchors/)
-   -   Henry 1KD-5 Amp (https://www.radiobanter.com/boatanchors/157846-henry-1kd-5-amp.html)

[email protected] January 9th 11 11:08 PM

Henry 1KD-5 Amp
 
In the 1KD-5 amp there is a RCA jack in the Fil centertap line just
below the Bias Zener..The jack has a shorting plug ...Nothing in the
manual ,what is it`s purpose? Thanks Harold

coffelt2 January 10th 11 06:24 AM

Henry 1KD-5 Amp
 

wrote in message
...
In the 1KD-5 amp there is a RCA jack in the Fil centertap line just
below the Bias Zener..The jack has a shorting plug ...Nothing in the
manual ,what is it`s purpose? Thanks Harold


I'm not familiar with this AMP, but in the "olden days" cathode current
was often measured by inserting an ammeter (OK, a milliammeter) in the
filament (it is the cathode) transformer's center tap to ground. (the
shorting plug provided current path when the meter was not in the circuit)
Isn't that how this 3-500Z works too?

Old Chief Lynn, W7LTQ


Edward Knobloch January 10th 11 07:30 AM

Henry 1KD-5 Amp
 
wrote in message
In the 1KD-5 amp there is a RCA jack in the Fil centertap line just
below the Bias Zener..The jack has a shorting plug ...Nothing in the
manual ,what is it`s purpose? Thanks Harold


Hi,
Looking at the schematic of this amp,
I believe you would normally leave the shorted phono plug
in J3 (note the shell of the J3 connector isn't grounded).

Should you want to calibrate the Grid or Plate current
meter reading in the amp, remove the plug and insert
an ammeter between center pin and shell.
Henry used trim pots to set the plate and grid
current readings (VR1 and VR2), so this would have been
a factory adjustment procedure.

Note that the HV supply is not returned directly to ground, but to R10
in the power supply (the grid current sensing resistor),
the top of which connects to terminal 2
and then continues to the metering circuit in the amp.
Since the 3-500Z tube grid is connected to ground,
grid current is measured indirectly. An old ARRL handbook
will show how this is done (See the 3-1000Z amplifier
metering in the 1963 Handbook, page 207, for instance).

73,
Ed Knobloch