TX Bias setting for TRC-457 type radios
I have the service manual but it is in storage, would like to know the
mA setting for VR15 and VR16. thanks, Homer |
TX Bias setting for TRC-457 type radios
Homer wrote:
I have the service manual but it is in storage, would like to know the mA setting for VR15 and VR16. 100ma? |
TX Bias setting for TRC-457 type radios
No, I know they are both different. One is higher.
Homer |
TX Bias setting for TRC-457 type radios
Homer wrote:
No, I know they are both different. One is higher. Homer A TRC-465 is 65mA for driver and 70mA for final. You can always measure the voltage to it. You need .67 volts to overcome the diode's junction on the base. |
TX Bias setting for TRC-457 type radios
Thanks for the replies, I went and got my book from storage.
FYI: VR15 = 40ma VR16 = 15ma. Homer |