Old December 23rd 03, 03:50 AM
Harvey Babb
 
Posts: n/a
Default

The MOV (Metal Oxide Varistor) is a surge supressor whose only function
is to absorb the "kick" when the mechanical thermostat opens (or
"bounces" when closing). The one in the Weller unit (if memory serves)
clamps the voltage at about 40 volts (Transformer secondary is 24 VAC).
If it isn't working properly the thermostat contacts arc and weld shut,
causing runaway overheating.

Frank Dinger wrote:

While you're at it, check one more thing! If the problem turns out to be
welded contacts on the thermostat switch, check that the MOV across the
secondary of the transformer is still good. I had one that repeatedly
welded the contacts till I replaced the MOV and has worked for 5 years
now without a problem.

=============================
Not having such a Weller soldering iron myself ,nevertheless I am interested
in the MOV (firing) voltage against the normal operating voltage . Also , is
it DC or AC ?

Frank GM0CSZ / KN6WH







 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
new 2m repeater on space station g3zhi Antenna 0 September 13th 04 11:17 AM
Special event station F4ASK Dx 0 September 3rd 04 04:55 PM
Special event station F4ASK Dx 0 September 3rd 04 11:38 AM
Amateur Radio Newsline™ Report 1400 ­ June 11, 2004 Radionews Dx 0 June 16th 04 08:34 PM
Amateur Radio Newsline™ Report 1400 ­ June 11, 2004 Radionews Dx 0 June 16th 04 08:34 PM


All times are GMT +1. The time now is 09:33 AM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017