Home |
Search |
Today's Posts |
#4
![]() |
|||
|
|||
![]()
I had two of those go out on me in a week, caused by a brown out. BOTH
cases, the bridge went bad. The brown out affected nothing else. Not the computers still on, radios, anything - but the Astron 20As fried. I'd definitely go for the Bridge to check. G.W. "Mark Russo" wrote in message ... Also check the bridge rectifier or the 4 diodes, don't recall what was in there. Maybe one or all are shorted? Nitespark wrote: Carl Franck wrote: Dear NewsReaders, I have a Astron RS-20A power supply that has started blowing its fuse even without a load. Until now it has been perfectly reliable. I would be much obliged for any advice as to what to look for first as I try to repair it. Sincerely, Carl KB2KDV Possibly a bad pass transistor. Try pulling each pass transistor out one at a time (or pull them all out and put them back one at a time until you blow a fuse) or if you have a transistor checker, check them. Another possibility, is you are getting an over voltage and the crow-bar circuit is activated. This could be caused by a problem in the regulator circuit. Possibly a bad LM723 regulator IC. These chips are pretty inexpensive and readily available. Andy WD4KDN -- Gun Control works!!! 3 million Holocaust victims can't be wrong. |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
HELP Astron 70 amp PS | Boatanchors | |||
Heathkit SB-200 Amplifier Problem Help? | Boatanchors | |||
National NCX-5 transmit/receive offset problem | Equipment | |||
Problem with transient spike on Astron RS-50M Power Supply | Equipment | |||
Problem with transient spike on Astron RS-50M Power Supply | Equipment |