Rollo Tomassi July 9th 04 09:34 AM

malfunction sub RX FT1000D
 
Hello,

My Yeasu FT1000D has no RX on the SUB-receiver until ... i touch the coils
from the RF-section T1028 and T6001 in the SuB-RXsection.
The same is that on D 1060 on the RF-section.
The RX on the sub is then coming back.
Between T1028/D1060 and T6001 is a bleu coax-cable.
I checked the bleu cable who connects the SUB-RX section with the RF-section
but that cable is OK.
I checked relay 1004 on the RF-section but is OK.
Main-RX is 100% .
Do someone has a solution except to bring it to the repairman ( He is on
holiday,HI)








dale.j. July 9th 04 10:54 AM

In article ,
"Rollo Tomassi" wrote:

Hello,

My Yeasu FT1000D has no RX on the SUB-receiver until ... i touch the coils
from the RF-section T1028 and T6001 in the SuB-RXsection.
The same is that on D 1060 on the RF-section.
The RX on the sub is then coming back.
Between T1028/D1060 and T6001 is a bleu coax-cable.
I checked the bleu cable who connects the SUB-RX section with the RF-section
but that cable is OK.
I checked relay 1004 on the RF-section but is OK.
Main-RX is 100% .
Do someone has a solution except to bring it to the repairman ( He is on
holiday,HI)


take it out and look carefully with a magnifier for cold solder joints
on the foil side or where ever there are solder joints. Otherwise I
don't know unless it may be a oscillator not running until you touch
something.

Good luck.

--
Email:

dale.j. July 9th 04 10:54 AM

In article ,
"Rollo Tomassi" wrote:

Hello,

My Yeasu FT1000D has no RX on the SUB-receiver until ... i touch the coils
from the RF-section T1028 and T6001 in the SuB-RXsection.
The same is that on D 1060 on the RF-section.
The RX on the sub is then coming back.
Between T1028/D1060 and T6001 is a bleu coax-cable.
I checked the bleu cable who connects the SUB-RX section with the RF-section
but that cable is OK.
I checked relay 1004 on the RF-section but is OK.
Main-RX is 100% .
Do someone has a solution except to bring it to the repairman ( He is on
holiday,HI)


take it out and look carefully with a magnifier for cold solder joints
on the foil side or where ever there are solder joints. Otherwise I
don't know unless it may be a oscillator not running until you touch
something.

Good luck.

--
Email:

Rollo Tomassi July 10th 04 06:36 PM

Thanks Dale for your idea , the malfunction is repaired , one of the
transformers was lose......




"dale.j. " schreef in bericht
...
In article ,
"Rollo Tomassi" wrote:

Hello,

My Yeasu FT1000D has no RX on the SUB-receiver until ... i touch the

coils
from the RF-section T1028 and T6001 in the SuB-RXsection.
The same is that on D 1060 on the RF-section.
The RX on the sub is then coming back.
Between T1028/D1060 and T6001 is a bleu coax-cable.
I checked the bleu cable who connects the SUB-RX section with the

RF-section
but that cable is OK.
I checked relay 1004 on the RF-section but is OK.
Main-RX is 100% .
Do someone has a solution except to bring it to the repairman ( He is on
holiday,HI)


take it out and look carefully with a magnifier for cold solder joints
on the foil side or where ever there are solder joints. Otherwise I
don't know unless it may be a oscillator not running until you touch
something.

Good luck.

--
Email:




Rollo Tomassi July 10th 04 06:36 PM

Thanks Dale for your idea , the malfunction is repaired , one of the
transformers was lose......




"dale.j. " schreef in bericht
...
In article ,
"Rollo Tomassi" wrote:

Hello,

My Yeasu FT1000D has no RX on the SUB-receiver until ... i touch the

coils
from the RF-section T1028 and T6001 in the SuB-RXsection.
The same is that on D 1060 on the RF-section.
The RX on the sub is then coming back.
Between T1028/D1060 and T6001 is a bleu coax-cable.
I checked the bleu cable who connects the SUB-RX section with the

RF-section
but that cable is OK.
I checked relay 1004 on the RF-section but is OK.
Main-RX is 100% .
Do someone has a solution except to bring it to the repairman ( He is on
holiday,HI)


take it out and look carefully with a magnifier for cold solder joints
on the foil side or where ever there are solder joints. Otherwise I
don't know unless it may be a oscillator not running until you touch
something.

Good luck.

--
Email:




dale.j. July 10th 04 09:54 PM

In article ,
"Rollo Tomassi" wrote:

Thanks Dale for your idea , the malfunction is repaired , one of the
transformers was lose......



Good show. Happy DXing.

73
Dale, K9VUJ








"dale.j. " schreef in bericht
...
In article ,
"Rollo Tomassi" wrote:

Hello,

My Yeasu FT1000D has no RX on the SUB-receiver until ... i touch the

coils
from the RF-section T1028 and T6001 in the SuB-RXsection.
The same is that on D 1060 on the RF-section.
The RX on the sub is then coming back.
Between T1028/D1060 and T6001 is a bleu coax-cable.
I checked the bleu cable who connects the SUB-RX section with the

RF-section
but that cable is OK.
I checked relay 1004 on the RF-section but is OK.
Main-RX is 100% .
Do someone has a solution except to bring it to the repairman ( He is on
holiday,HI)


take it out and look carefully with a magnifier for cold solder joints
on the foil side or where ever there are solder joints. Otherwise I
don't know unless it may be a oscillator not running until you touch
something.

Good luck.

--
Email:


--
Email:


dale.j. July 10th 04 09:54 PM

In article ,
"Rollo Tomassi" wrote:

Thanks Dale for your idea , the malfunction is repaired , one of the
transformers was lose......



Good show. Happy DXing.

73
Dale, K9VUJ








"dale.j. " schreef in bericht
...
In article ,
"Rollo Tomassi" wrote:

Hello,

My Yeasu FT1000D has no RX on the SUB-receiver until ... i touch the

coils
from the RF-section T1028 and T6001 in the SuB-RXsection.
The same is that on D 1060 on the RF-section.
The RX on the sub is then coming back.
Between T1028/D1060 and T6001 is a bleu coax-cable.
I checked the bleu cable who connects the SUB-RX section with the

RF-section
but that cable is OK.
I checked relay 1004 on the RF-section but is OK.
Main-RX is 100% .
Do someone has a solution except to bring it to the repairman ( He is on
holiday,HI)


take it out and look carefully with a magnifier for cold solder joints
on the foil side or where ever there are solder joints. Otherwise I
don't know unless it may be a oscillator not running until you touch
something.

Good luck.

--
Email:


--
Email:


mike July 14th 04 11:20 PM

you say "if i touch the coils, the RX comes back"
is it then getting ham station as ok should work or radio station thru
mutual coupling with your finger.??


mike
"Rollo Tomassi" wrote in message
...
Hello,

My Yeasu FT1000D has no RX on the SUB-receiver until ... i touch the coils
from the RF-section T1028 and T6001 in the SuB-RXsection.
The same is that on D 1060 on the RF-section.
The RX on the sub is then coming back.
Between T1028/D1060 and T6001 is a bleu coax-cable.
I checked the bleu cable who connects the SUB-RX section with the

RF-section
but that cable is OK.
I checked relay 1004 on the RF-section but is OK.
Main-RX is 100% .
Do someone has a solution except to bring it to the repairman ( He is on
holiday,HI)









---
Outgoing mail is certified Virus Free.
Checked by AVG anti-virus system (http://www.grisoft.com).
Version: 6.0.719 / Virus Database: 475 - Release Date: 12/07/2004



mike July 14th 04 11:20 PM

you say "if i touch the coils, the RX comes back"
is it then getting ham station as ok should work or radio station thru
mutual coupling with your finger.??


mike
"Rollo Tomassi" wrote in message
...
Hello,

My Yeasu FT1000D has no RX on the SUB-receiver until ... i touch the coils
from the RF-section T1028 and T6001 in the SuB-RXsection.
The same is that on D 1060 on the RF-section.
The RX on the sub is then coming back.
Between T1028/D1060 and T6001 is a bleu coax-cable.
I checked the bleu cable who connects the SUB-RX section with the

RF-section
but that cable is OK.
I checked relay 1004 on the RF-section but is OK.
Main-RX is 100% .
Do someone has a solution except to bring it to the repairman ( He is on
holiday,HI)









---
Outgoing mail is certified Virus Free.
Checked by AVG anti-virus system (http://www.grisoft.com).
Version: 6.0.719 / Virus Database: 475 - Release Date: 12/07/2004



Rusty O July 15th 04 06:28 PM

Rollo Tomassi.......

Isn't he the evil one that gets away his crimes?



From the movie "L.A. Confidential".

Rusty O



Rusty O July 15th 04 06:28 PM

Rollo Tomassi.......

Isn't he the evil one that gets away his crimes?



From the movie "L.A. Confidential".

Rusty O



Rollo Tomassi July 15th 04 06:51 PM


Yes !!!!!!!!!!! He is always gottaway.... with his FT1000D.....

"Rusty O" schreef in bericht
ink.net...
Rollo Tomassi.......

Isn't he the evil one that gets away his crimes?



From the movie "L.A. Confidential".

Rusty O





Rollo Tomassi July 15th 04 06:51 PM


Yes !!!!!!!!!!! He is always gottaway.... with his FT1000D.....

"Rusty O" schreef in bericht
ink.net...
Rollo Tomassi.......

Isn't he the evil one that gets away his crimes?



From the movie "L.A. Confidential".

Rusty O






All times are GMT +1. The time now is 05:04 PM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
RadioBanter.com