Home |
Search |
Today's Posts |
#2
![]() |
|||
|
|||
![]()
"JimL" wrote in message
. com... Greetings- can someone provide data on their home made choke for connecting across the output of a 1 KW, 3.5 mhz , transmitter working into 50 ohms. The so called safety choke to prevent the HV plate voltage from appearing on the antenna in case of failure of a blocking capacitor. Normally a commercial 2.5 MHY RFC is used. Perhaps something wound on a ferrite rod. Thanks, Jim. You might try calculating the inductance of a choke that presents about 500 to 1000 ohms of inductive reactance of the transmitter frequency. Use wire that can handle about 2 to 3 times the plate current of the final, or 2 to 3 times the HV fuse rating. The math is left as an exercise for the OP. -- Dave M MasonDG44 at comcast dot net (Just substitute the appropriate characters in the address) "In theory, there isn't any difference between theory and practice. In practice, there is." - Yogi Berra |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Choke /BALUN | Antenna | |||
Choke baluns again | Antenna | |||
Choke enough? | Antenna | |||
FS SR-500 splatter choke | Boatanchors | |||
FS SR-500 splatter choke | Boatanchors |