Scott[_4_] April 26th 10 12:39 AM

HP 5245L Counter Oscillator adjust?
 
I'm trying to download a copy of the manual, but at the rate it's
downloading, I may have it by Tuesday, April 27th.....2013!

Anyhow...does anyone have a copy of how to set the timebase oscillator
frequency? I measure the signal coming out the back of the counter
(with another counter) at 10.000066 MHz. I adjusted the "coarse tune"
adjustment on the back of the unit and this is as close as it gets to
10.000000 MHz, so I assume there must be some other adjustment
somewhere...I took off both covers, but any adjustment control is not
blatantly obvious....

Scott
N0EDV

Dave M[_3_] April 26th 10 02:41 AM

HP 5245L Counter Oscillator adjust?
 
Scott wrote:
I'm trying to download a copy of the manual, but at the rate it's
downloading, I may have it by Tuesday, April 27th.....2013!

Anyhow...does anyone have a copy of how to set the timebase oscillator
frequency? I measure the signal coming out the back of the counter
(with another counter) at 10.000066 MHz. I adjusted the "coarse tune"
adjustment on the back of the unit and this is as close as it gets to
10.000000 MHz, so I assume there must be some other adjustment
somewhere...I took off both covers, but any adjustment control is not
blatantly obvious....

Scott
N0EDV


Scott,
I've seen the oven temperature control circuit more likely to cause this
type of problem. The fact that the oscillator is working eliminates a lot of
circuitry.

Before you do any more adjusting, do this:
Check that the oven temperature control circuit is working. Check to see if
the collector of Q1 is in the ballpark of about -21 volts. That point
should start out (cold oven) at around -5 volts or so, and go toward -21
volts as the oven warms up. If it stays at the lower voltage, you have a
problem with either Q1 or one of the transistors on the oven control assy
A25. That same reasoning goes if the voltage at Q1 collector starts out and
stays at -35 volts or so.
An extreme cause would be that of the oven heater being open. In that case,
the oven assembly is bad, and will need to be replaced. You can attempt ot
disassemble the oven and repair the heater, but it's iffy. One of the temp
sensor components inside the oven might be bad as well.
If the oven and the oven control is OK, that means that the oscillator is
out of tune. That could be caused by the crystal itself, of one of the
capacitors inside the oven.

I have an operable oven assembly that we could make a deal on, but since I
recently moved from Florida to Alabama and don't have a shop area yet, it's
still in storage. If you can wait for a couple of months, I could dig it
out for you. You might look on Ebay for an oven; I've seen them offerred
there, but not often.

--
David
dgminala at mediacombb dot net




Andrew VK3BFA[_3_] April 27th 10 01:45 PM

HP 5245L Counter Oscillator adjust?
 
On Apr 26, 11:41*am, "Dave M" wrote:
Scott wrote:
I'm trying to download a copy of the manual, but at the rate it's
downloading, I may have it by Tuesday, April 27th.....2013!


Anyhow...does anyone have a copy of how to set the timebase oscillator
frequency? *I measure the signal coming out the back of the counter
(with another counter) at 10.000066 MHz. *I adjusted the "coarse tune"
adjustment on the back of the unit and this is as close as it gets to
10.000000 MHz, so I assume there must be some other adjustment
somewhere...I took off both covers, but any adjustment control is not
blatantly obvious....


Scott
N0EDV


Scott,
I've seen the oven temperature control circuit more likely to cause this
type of problem. The fact that the oscillator is working eliminates a lot of
circuitry.

Before you do any more adjusting, do this:
Check that the oven temperature control circuit is working. *Check to see if
the collector of Q1 is in the ballpark of about -21 volts. *That point
should start out (cold oven) at around -5 volts or so, and go toward -21
volts as the oven warms up. *If it stays at the lower voltage, you have a
problem with either Q1 or one of the transistors on the oven control assy
A25. *That same reasoning goes if the voltage at Q1 collector starts out and
stays at -35 volts or so.
An extreme cause would be that of the oven heater being open. *In that case,
the oven assembly is bad, and will need to be replaced. *You can attempt ot
disassemble the oven and repair the heater, but it's iffy. *One of the temp
sensor components inside the oven might be bad as well.
If the oven and the oven control is OK, that means that the oscillator is
out of tune. *That could be caused by the crystal itself, of one of the
capacitors inside the oven.

I have an operable oven assembly that we could make a deal on, but since I
recently moved from Florida to Alabama and don't have a shop area yet, it's
still in storage. *If you can wait for a couple of months, I could dig it
out for you. You might look on Ebay for an oven; I've seen them offerred
there, but not often.

--
David
dgminala at mediacombb dot net


Excuse me for seeming a Patronising Old ******* here, but I feel some
basic radio theory is in order here, and to respond to the original
question......

Quote.
I measure the signal coming out the back of the counter
(with another counter) at 10.000066 MHz.


Response.
How accurate is the frequency counter you are using to measure the
10Mhz TXCO? (and does it have a current calibration certificate?) -
unless it is at least an order of magnitude BETTER than the HP, any
results will be meaningless. Your comparing the HP ref. signal
to......what?....

A easier way is to zero beat the HP TXCO with WWV. Yes, for the
purists, there are problems with this method, (which are NOT relevant
here) but if you tune for zerobeat by ear as best you can - by then,
the S meter should be pulsating (it can see the beat note, you cant
hear it) and then tune.

Get really hi-tech, use a GPS locked counter.

And I hope you took notes of the original "frequency" and can take it
back to this. Its a well aged, ovenized xtal. It will be pretty bloody
close, unless someone has been into it before you.....

These things were, in their day, laboratory grade instruments. They
still are, but have been superseded as technology advanced. You need
to learn what the display is telling you, and how much is relevant to
what you do. Its unlikely that you will be building something that
needs 10-12 accuracy. (A nominal figure, not going to dig the manual
out to look)

The error you quote is totally insignificant for average amateur (and
most professional ) use.

If the oven is working, it will get warm. Simple.
Plot the frequency change from cold switch on - see how long it takes
to stabilise. Do it again, later, when the ambient room temperature
has changed. If no shift, its OK. And if it is not working......well,
they ARE fascinating instruments, the service manual a joy to read.
(Bout the size of the phone book) They even give Boolean equations for
it. You could be entranced by 1960's technology - if you so choose.
g

Later model ones had a "Oven"light on the front panel - if it was out
after warm-up, then it was ok. BTW - anyone got a service manual for a
HP5248L counter.......got a gating fault, how similar are they to the
5245L - any HP test gurus out there?

In good faith, and hopefully no insult intended or received.

Andrew VK3BFA.



Dave M[_3_] April 27th 10 02:19 PM

HP 5245L Counter Oscillator adjust?
 
Andrew VK3BFA wrote:
On Apr 26, 11:41 am, "Dave M" wrote:
Scott wrote:
I'm trying to download a copy of the manual, but at the rate it's
downloading, I may have it by Tuesday, April 27th.....2013!


Anyhow...does anyone have a copy of how to set the timebase
oscillator frequency? I measure the signal coming out the back of
the counter (with another counter) at 10.000066 MHz. I adjusted the
"coarse tune" adjustment on the back of the unit and this is as
close as it gets to
10.000000 MHz, so I assume there must be some other adjustment
somewhere...I took off both covers, but any adjustment control is
not blatantly obvious....


Scott
N0EDV


Scott,
I've seen the oven temperature control circuit more likely to cause
this type of problem. The fact that the oscillator is working
eliminates a lot of circuitry.

Before you do any more adjusting, do this:
Check that the oven temperature control circuit is working. Check to
see if the collector of Q1 is in the ballpark of about -21 volts.
That point should start out (cold oven) at around -5 volts or so,
and go toward -21 volts as the oven warms up. If it stays at the
lower voltage, you have a problem with either Q1 or one of the
transistors on the oven control assy A25. That same reasoning goes
if the voltage at Q1 collector starts out and stays at -35 volts or
so.
An extreme cause would be that of the oven heater being open. In
that case, the oven assembly is bad, and will need to be replaced.
You can attempt ot disassemble the oven and repair the heater, but
it's iffy. One of the temp sensor components inside the oven might
be bad as well.
If the oven and the oven control is OK, that means that the
oscillator is out of tune. That could be caused by the crystal
itself, of one of the capacitors inside the oven.

I have an operable oven assembly that we could make a deal on, but
since I recently moved from Florida to Alabama and don't have a shop
area yet, it's still in storage. If you can wait for a couple of
months, I could dig it out for you. You might look on Ebay for an
oven; I've seen them offerred there, but not often.

--
David
dgminala at mediacombb dot net


Excuse me for seeming a Patronising Old ******* here, but I feel some
basic radio theory is in order here, and to respond to the original
question......

Quote.
I measure the signal coming out the back of the counter
(with another counter) at 10.000066 MHz.


Response.
How accurate is the frequency counter you are using to measure the
10Mhz TXCO? (and does it have a current calibration certificate?) -
unless it is at least an order of magnitude BETTER than the HP, any
results will be meaningless. Your comparing the HP ref. signal
to......what?....

A easier way is to zero beat the HP TXCO with WWV. Yes, for the
purists, there are problems with this method, (which are NOT relevant
here) but if you tune for zerobeat by ear as best you can - by then,
the S meter should be pulsating (it can see the beat note, you cant
hear it) and then tune.

Get really hi-tech, use a GPS locked counter.

And I hope you took notes of the original "frequency" and can take it
back to this. Its a well aged, ovenized xtal. It will be pretty bloody
close, unless someone has been into it before you.....

These things were, in their day, laboratory grade instruments. They
still are, but have been superseded as technology advanced. You need
to learn what the display is telling you, and how much is relevant to
what you do. Its unlikely that you will be building something that
needs 10-12 accuracy. (A nominal figure, not going to dig the manual
out to look)

The error you quote is totally insignificant for average amateur (and
most professional ) use.

If the oven is working, it will get warm. Simple.
Plot the frequency change from cold switch on - see how long it takes
to stabilise. Do it again, later, when the ambient room temperature
has changed. If no shift, its OK. And if it is not working......well,
they ARE fascinating instruments, the service manual a joy to read.
(Bout the size of the phone book) They even give Boolean equations for
it. You could be entranced by 1960's technology - if you so choose.
g

Later model ones had a "Oven"light on the front panel - if it was out
after warm-up, then it was ok. BTW - anyone got a service manual for a
HP5248L counter.......got a gating fault, how similar are they to the
5245L - any HP test gurus out there?

In good faith, and hopefully no insult intended or received.

Andrew VK3BFA.


The 5248L manual is on Agilent's site at
http://cp.literature.agilent.com/lit...5248-90001.pdf. I can't say how
similar they are to the 5245L, but the DCUs seem to be the same. I used to
be a calibration tech many years ago, and while I saw many of both
instruments on my bench, I rarely had to repair them; quite reliable. I
remember two cases where the counters exhibited the exact problem the OP
has; significant oscillator error. Both turned out to be problems with the
oven control circuit.

I have to disagree with your statement that the OP's error is insignigicant
for professional use. That might be true for some hobbiest uses, but for
many amateur radio operators and certainly for professional use, it's a
very significant error. The original time base spec for the 5245L is
3x10^-9 per day.
--
David
dgminala at mediacombb dot net




Andrew VK3BFA[_3_] April 27th 10 02:30 PM

HP 5245L Counter Oscillator adjust?
 
On Apr 27, 11:19*pm, "Dave M" wrote:
Andrew VK3BFA wrote:
On Apr 26, 11:41 am, "Dave M" wrote:
Scott wrote:
I'm trying to download a copy of the manual, but at the rate it's
downloading, I may have it by Tuesday, April 27th.....2013!


Anyhow...does anyone have a copy of how to set the timebase
oscillator frequency? I measure the signal coming out the back of
the counter (with another counter) at 10.000066 MHz. I adjusted the
"coarse tune" adjustment on the back of the unit and this is as
close as it gets to
10.000000 MHz, so I assume there must be some other adjustment
somewhere...I took off both covers, but any adjustment control is
not blatantly obvious....


Scott
N0EDV


Scott,
I've seen the oven temperature control circuit more likely to cause
this type of problem. The fact that the oscillator is working
eliminates a lot of circuitry.


Before you do any more adjusting, do this:
Check that the oven temperature control circuit is working. Check to
see if the collector of Q1 is in the ballpark of about -21 volts.
That point should start out (cold oven) at around -5 volts or so,
and go toward -21 volts as the oven warms up. If it stays at the
lower voltage, you have a problem with either Q1 or one of the
transistors on the oven control assy A25. That same reasoning goes
if the voltage at Q1 collector starts out and stays at -35 volts or
so.
An extreme cause would be that of the oven heater being open. In
that case, the oven assembly is bad, and will need to be replaced.
You can attempt ot disassemble the oven and repair the heater, but
it's iffy. One of the temp sensor components inside the oven might
be bad as well.
If the oven and the oven control is OK, that means that the
oscillator is out of tune. That could be caused by the crystal
itself, of one of the capacitors inside the oven.


I have an operable oven assembly that we could make a deal on, but
since I recently moved from Florida to Alabama and don't have a shop
area yet, it's still in storage. If you can wait for a couple of
months, I could dig it out for you. You might look on Ebay for an
oven; I've seen them offerred there, but not often.


--
David
dgminala at mediacombb dot net


Excuse me for seeming a Patronising Old ******* here, but I feel some
basic radio theory is in order here, and to respond to the original
question......


Quote.
*I measure the signal coming out the back of the counter
(with another counter) at 10.000066 MHz.


Response.
How accurate is the frequency counter you are using to measure the
10Mhz TXCO? *(and does it have a current calibration certificate?) -
unless it is at least an order of magnitude BETTER than the HP, any
results will be meaningless. *Your comparing the HP ref. signal
to......what?....


A easier way is to zero beat the HP TXCO with WWV. Yes, for the
purists, there are problems with this method, (which are NOT relevant
here) but if you tune for zerobeat by ear as best you can - by then,
the S meter should be pulsating (it can see the beat note, you cant
hear it) and then tune.


Get really hi-tech, use a GPS locked counter.


And I hope you took notes of the original "frequency" and can take it
back to this. Its a well aged, ovenized xtal. It will be pretty bloody
close, unless someone has been into it before you.....


These things were, in their day, laboratory grade instruments. They
still are, but have been superseded as technology advanced. You need
to learn what the display is telling you, and how much is relevant to
what you do. Its unlikely that you will be building something that
needs 10-12 accuracy. (A nominal figure, not going to dig the manual
out to look)


The error you quote is totally insignificant for average amateur (and
most professional ) use.


If the oven is working, it will get warm. Simple.
Plot the frequency change from cold switch on - see how long it takes
to stabilise. Do it again, later, when the ambient room temperature
has changed. If no shift, its OK. And if it is not working......well,
they ARE fascinating instruments, the service manual a joy to read.
(Bout the size of the phone book) They even give Boolean equations for
it. *You could be entranced by 1960's technology - if you so choose.
g


Later model ones had a "Oven"light on the front panel - if it was out
after warm-up, then it was ok. BTW - anyone got a service manual for a
HP5248L counter.......got a gating fault, how similar are they to the
5245L - any HP test gurus out there?


In good faith, and hopefully no insult intended or received.


Andrew VK3BFA.


The 5248L manual is on Agilent's site athttp://cp.literature.agilent.com/litweb/pdf/05248-90001.pdf. I can't say how
similar they are to the 5245L, but the DCUs seem to be the same. *I used to
be a calibration tech many years ago, and while I saw many of both
instruments on my bench, I rarely had to repair them; quite reliable. *I
remember two cases where the counters exhibited the exact problem the OP
has; significant oscillator error. *Both turned out to be problems with the
oven control circuit.

I have to disagree with your statement that the OP's error is insignigicant
for professional use. *That might be true for some hobbiest uses, but for
many amateur radio operators and certainly for professional use, *it's a
very significant error. * The original time base spec for the 5245L is
3x10^-9 per day.
--
David
dgminala at mediacombb dot net


David, than you for the link - will try for it, and hopefully it can
run overnight here. I stand corrected re accuracy - as I said, I
should have dig out the manual, (and, indeed, revise my own theory re
where the decimal point goes) a bit better.
I was hoping someone like you would stick their head up - helps to
talk to someone who has actually worked on them as a job.....thanks
mate, appreciated.

Andrew VK3BFA.

Andrew VK3BFA[_3_] April 27th 10 02:43 PM

HP 5245L Counter Oscillator adjust?
 
On Apr 27, 11:19*pm, "Dave M" wrote:
Andrew VK3BFA wrote:
On Apr 26, 11:41 am, "Dave M" wrote:
Scott wrote:
I'm trying to download a copy of the manual, but at the rate it's
downloading, I may have it by Tuesday, April 27th.....2013!


Anyhow...does anyone have a copy of how to set the timebase
oscillator frequency? I measure the signal coming out the back of
the counter (with another counter) at 10.000066 MHz. I adjusted the
"coarse tune" adjustment on the back of the unit and this is as
close as it gets to
10.000000 MHz, so I assume there must be some other adjustment
somewhere...I took off both covers, but any adjustment control is
not blatantly obvious....


Scott
N0EDV


Scott,
I've seen the oven temperature control circuit more likely to cause
this type of problem. The fact that the oscillator is working
eliminates a lot of circuitry.


Before you do any more adjusting, do this:
Check that the oven temperature control circuit is working. Check to
see if the collector of Q1 is in the ballpark of about -21 volts.
That point should start out (cold oven) at around -5 volts or so,
and go toward -21 volts as the oven warms up. If it stays at the
lower voltage, you have a problem with either Q1 or one of the
transistors on the oven control assy A25. That same reasoning goes
if the voltage at Q1 collector starts out and stays at -35 volts or
so.
An extreme cause would be that of the oven heater being open. In
that case, the oven assembly is bad, and will need to be replaced.
You can attempt ot disassemble the oven and repair the heater, but
it's iffy. One of the temp sensor components inside the oven might
be bad as well.
If the oven and the oven control is OK, that means that the
oscillator is out of tune. That could be caused by the crystal
itself, of one of the capacitors inside the oven.


I have an operable oven assembly that we could make a deal on, but
since I recently moved from Florida to Alabama and don't have a shop
area yet, it's still in storage. If you can wait for a couple of
months, I could dig it out for you. You might look on Ebay for an
oven; I've seen them offerred there, but not often.


--
David
dgminala at mediacombb dot net


Excuse me for seeming a Patronising Old ******* here, but I feel some
basic radio theory is in order here, and to respond to the original
question......


Quote.
*I measure the signal coming out the back of the counter
(with another counter) at 10.000066 MHz.


Response.
How accurate is the frequency counter you are using to measure the
10Mhz TXCO? *(and does it have a current calibration certificate?) -
unless it is at least an order of magnitude BETTER than the HP, any
results will be meaningless. *Your comparing the HP ref. signal
to......what?....


A easier way is to zero beat the HP TXCO with WWV. Yes, for the
purists, there are problems with this method, (which are NOT relevant
here) but if you tune for zerobeat by ear as best you can - by then,
the S meter should be pulsating (it can see the beat note, you cant
hear it) and then tune.


Get really hi-tech, use a GPS locked counter.


And I hope you took notes of the original "frequency" and can take it
back to this. Its a well aged, ovenized xtal. It will be pretty bloody
close, unless someone has been into it before you.....


These things were, in their day, laboratory grade instruments. They
still are, but have been superseded as technology advanced. You need
to learn what the display is telling you, and how much is relevant to
what you do. Its unlikely that you will be building something that
needs 10-12 accuracy. (A nominal figure, not going to dig the manual
out to look)


The error you quote is totally insignificant for average amateur (and
most professional ) use.


If the oven is working, it will get warm. Simple.
Plot the frequency change from cold switch on - see how long it takes
to stabilise. Do it again, later, when the ambient room temperature
has changed. If no shift, its OK. And if it is not working......well,
they ARE fascinating instruments, the service manual a joy to read.
(Bout the size of the phone book) They even give Boolean equations for
it. *You could be entranced by 1960's technology - if you so choose.
g


Later model ones had a "Oven"light on the front panel - if it was out
after warm-up, then it was ok. BTW - anyone got a service manual for a
HP5248L counter.......got a gating fault, how similar are they to the
5245L - any HP test gurus out there?


In good faith, and hopefully no insult intended or received.


Andrew VK3BFA.


The 5248L manual is on Agilent's site athttp://cp.literature.agilent.com/litweb/pdf/05248-90001.pdf. I can't say how
similar they are to the 5245L, but the DCUs seem to be the same. *I used to
be a calibration tech many years ago, and while I saw many of both
instruments on my bench, I rarely had to repair them; quite reliable. *I
remember two cases where the counters exhibited the exact problem the OP
has; significant oscillator error. *Both turned out to be problems with the
oven control circuit.

I have to disagree with your statement that the OP's error is insignigicant
for professional use. *That might be true for some hobbiest uses, but for
many amateur radio operators and certainly for professional use, *it's a
very significant error. * The original time base spec for the 5245L is
3x10^-9 per day.
--
David
dgminala at mediacombb dot net


Got it! - thank you. Paid $5 for it as an "under the table" item at a
Hamfest. Missing 2 front panel knobs, but will get it working properly
before I chase them. Got several plug ins for my 5245L, will
investigate if they are compatible..
Still a nice bit of gear....

Andrew VK3BFA.

Scott[_4_] April 28th 10 01:06 AM

HP 5245L Counter Oscillator adjust?
 
Andrew VK3BFA wrote:
On Apr 26, 11:41 am, "Dave M" wrote:
Scott wrote:
I'm trying to download a copy of the manual, but at the rate it's
downloading, I may have it by Tuesday, April 27th.....2013!
Anyhow...does anyone have a copy of how to set the timebase oscillator
frequency? I measure the signal coming out the back of the counter
(with another counter) at 10.000066 MHz. I adjusted the "coarse tune"
adjustment on the back of the unit and this is as close as it gets to
10.000000 MHz, so I assume there must be some other adjustment
somewhere...I took off both covers, but any adjustment control is not
blatantly obvious....
Scott
N0EDV

Scott,
I've seen the oven temperature control circuit more likely to cause this
type of problem. The fact that the oscillator is working eliminates a lot of
circuitry.

Before you do any more adjusting, do this:
Check that the oven temperature control circuit is working. Check to see if
the collector of Q1 is in the ballpark of about -21 volts. That point
should start out (cold oven) at around -5 volts or so, and go toward -21
volts as the oven warms up. If it stays at the lower voltage, you have a
problem with either Q1 or one of the transistors on the oven control assy
A25. That same reasoning goes if the voltage at Q1 collector starts out and
stays at -35 volts or so.
An extreme cause would be that of the oven heater being open. In that case,
the oven assembly is bad, and will need to be replaced. You can attempt ot
disassemble the oven and repair the heater, but it's iffy. One of the temp
sensor components inside the oven might be bad as well.
If the oven and the oven control is OK, that means that the oscillator is
out of tune. That could be caused by the crystal itself, of one of the
capacitors inside the oven.

I have an operable oven assembly that we could make a deal on, but since I
recently moved from Florida to Alabama and don't have a shop area yet, it's
still in storage. If you can wait for a couple of months, I could dig it
out for you. You might look on Ebay for an oven; I've seen them offerred
there, but not often.

--
David
dgminala at mediacombb dot net


Excuse me for seeming a Patronising Old ******* here, but I feel some
basic radio theory is in order here, and to respond to the original
question......

Quote.
I measure the signal coming out the back of the counter
(with another counter) at 10.000066 MHz.


Response.
How accurate is the frequency counter you are using to measure the
10Mhz TXCO? (and does it have a current calibration certificate?) -
unless it is at least an order of magnitude BETTER than the HP, any
results will be meaningless. Your comparing the HP ref. signal
to......what?....


Very accurate. It is our Agilent power meter/freq counter (to 26 GHz)
and has been cal'd.

A easier way is to zero beat the HP TXCO with WWV. Yes, for the
purists, there are problems with this method, (which are NOT relevant
here) but if you tune for zerobeat by ear as best you can - by then,
the S meter should be pulsating (it can see the beat note, you cant
hear it) and then tune.

Get really hi-tech, use a GPS locked counter.




And I hope you took notes of the original "frequency" and can take it
back to this. Its a well aged, ovenized xtal. It will be pretty bloody
close, unless someone has been into it before you.....


Yes, I did note the original freq.

These things were, in their day, laboratory grade instruments. They
still are, but have been superseded as technology advanced. You need
to learn what the display is telling you, and how much is relevant to
what you do. Its unlikely that you will be building something that
needs 10-12 accuracy. (A nominal figure, not going to dig the manual
out to look)

The error you quote is totally insignificant for average amateur (and
most professional ) use.


Well, I'm wanting to measure down to about 10 Hz "accuracy"...in other
words I am measuring 189.XXXXX MHz. This is the XTAL freq. for my
microwave LO that is multipled by 6 to get to 1136 MHz and that is
multiplied by 9 to get to 10224 MHz, for a total multiplication factor
of 54.

If the oven is working, it will get warm. Simple.


Now THAT'S something I need to check. It should be working...the unit
is only a bit over 40 years old! ;)


Plot the frequency change from cold switch on - see how long it takes
to stabilise. Do it again, later, when the ambient room temperature
has changed. If no shift, its OK. And if it is not working......well,
they ARE fascinating instruments, the service manual a joy to read.
(Bout the size of the phone book) They even give Boolean equations for
it. You could be entranced by 1960's technology - if you so choose.
g

Later model ones had a "Oven"light on the front panel - if it was out
after warm-up, then it was ok. BTW - anyone got a service manual for a
HP5248L counter.......got a gating fault, how similar are they to the
5245L - any HP test gurus out there?

In good faith, and hopefully no insult intended or received.


None taken. I work on microwave equipment at work all day long and can
get a bit worked up about "being on frequency" ;)

Thanks for the tips...the manual did finally download, so I'll dig into
it soon (the good news is I have two of these, so maybe I'll check the
other one and see how close it is. I just bought the second one for its
3-12 GHz mixer).

Scott
N0EDV

Andrew VK3BFA.



Scott[_4_] April 28th 10 01:09 AM

HP 5245L Counter Oscillator adjust?
 
Dave M wrote:
Andrew VK3BFA wrote:
On Apr 26, 11:41 am, "Dave M" wrote:
Scott wrote:
I'm trying to download a copy of the manual, but at the rate it's
downloading, I may have it by Tuesday, April 27th.....2013!
Anyhow...does anyone have a copy of how to set the timebase
oscillator frequency? I measure the signal coming out the back of
the counter (with another counter) at 10.000066 MHz. I adjusted the
"coarse tune" adjustment on the back of the unit and this is as
close as it gets to
10.000000 MHz, so I assume there must be some other adjustment
somewhere...I took off both covers, but any adjustment control is
not blatantly obvious....
Scott
N0EDV
Scott,
I've seen the oven temperature control circuit more likely to cause
this type of problem. The fact that the oscillator is working
eliminates a lot of circuitry.

Before you do any more adjusting, do this:
Check that the oven temperature control circuit is working. Check to
see if the collector of Q1 is in the ballpark of about -21 volts.
That point should start out (cold oven) at around -5 volts or so,
and go toward -21 volts as the oven warms up. If it stays at the
lower voltage, you have a problem with either Q1 or one of the
transistors on the oven control assy A25. That same reasoning goes
if the voltage at Q1 collector starts out and stays at -35 volts or
so.
An extreme cause would be that of the oven heater being open. In
that case, the oven assembly is bad, and will need to be replaced.
You can attempt ot disassemble the oven and repair the heater, but
it's iffy. One of the temp sensor components inside the oven might
be bad as well.
If the oven and the oven control is OK, that means that the
oscillator is out of tune. That could be caused by the crystal
itself, of one of the capacitors inside the oven.

I have an operable oven assembly that we could make a deal on, but
since I recently moved from Florida to Alabama and don't have a shop
area yet, it's still in storage. If you can wait for a couple of
months, I could dig it out for you. You might look on Ebay for an
oven; I've seen them offerred there, but not often.

--
David
dgminala at mediacombb dot net

Excuse me for seeming a Patronising Old ******* here, but I feel some
basic radio theory is in order here, and to respond to the original
question......

Quote.
I measure the signal coming out the back of the counter
(with another counter) at 10.000066 MHz.

Response.
How accurate is the frequency counter you are using to measure the
10Mhz TXCO? (and does it have a current calibration certificate?) -
unless it is at least an order of magnitude BETTER than the HP, any
results will be meaningless. Your comparing the HP ref. signal
to......what?....

A easier way is to zero beat the HP TXCO with WWV. Yes, for the
purists, there are problems with this method, (which are NOT relevant
here) but if you tune for zerobeat by ear as best you can - by then,
the S meter should be pulsating (it can see the beat note, you cant
hear it) and then tune.

Get really hi-tech, use a GPS locked counter.

And I hope you took notes of the original "frequency" and can take it
back to this. Its a well aged, ovenized xtal. It will be pretty bloody
close, unless someone has been into it before you.....

These things were, in their day, laboratory grade instruments. They
still are, but have been superseded as technology advanced. You need
to learn what the display is telling you, and how much is relevant to
what you do. Its unlikely that you will be building something that
needs 10-12 accuracy. (A nominal figure, not going to dig the manual
out to look)

The error you quote is totally insignificant for average amateur (and
most professional ) use.

If the oven is working, it will get warm. Simple.
Plot the frequency change from cold switch on - see how long it takes
to stabilise. Do it again, later, when the ambient room temperature
has changed. If no shift, its OK. And if it is not working......well,
they ARE fascinating instruments, the service manual a joy to read.
(Bout the size of the phone book) They even give Boolean equations for
it. You could be entranced by 1960's technology - if you so choose.
g

Later model ones had a "Oven"light on the front panel - if it was out
after warm-up, then it was ok. BTW - anyone got a service manual for a
HP5248L counter.......got a gating fault, how similar are they to the
5245L - any HP test gurus out there?

In good faith, and hopefully no insult intended or received.

Andrew VK3BFA.


The 5248L manual is on Agilent's site at
http://cp.literature.agilent.com/lit...5248-90001.pdf. I can't say how
similar they are to the 5245L, but the DCUs seem to be the same. I used to
be a calibration tech many years ago, and while I saw many of both
instruments on my bench, I rarely had to repair them; quite reliable. I
remember two cases where the counters exhibited the exact problem the OP
has; significant oscillator error. Both turned out to be problems with the
oven control circuit.

I have to disagree with your statement that the OP's error is insignigicant
for professional use. That might be true for some hobbiest uses, but for
many amateur radio operators and certainly for professional use, it's a
very significant error. The original time base spec for the 5245L is
3x10^-9 per day.


The oven has been mentioned in a few posts. I will try to establish if
that is working or if that's where the problem lays. I want to use it
to count my 189.XXXXX MHz XTAL freq in my 10 GHz transverter. I need
pretty good accuracy since this XTAL is multiplied by a factor of 54 in
the LO chain. Thanks for the tip!

Scott
N0EDV

JIMMIE April 28th 10 03:27 AM

HP 5245L Counter Oscillator adjust?
 
On Apr 27, 8:09*pm, Scott wrote:
Dave M wrote:
Andrew VK3BFA wrote:
On Apr 26, 11:41 am, "Dave M" wrote:
Scott wrote:
I'm trying to download a copy of the manual, but at the rate it's
downloading, I may have it by Tuesday, April 27th.....2013!
Anyhow...does anyone have a copy of how to set the timebase
oscillator frequency? I measure the signal coming out the back of
the counter (with another counter) at 10.000066 MHz. I adjusted the
"coarse tune" adjustment on the back of the unit and this is as
close as it gets to
10.000000 MHz, so I assume there must be some other adjustment
somewhere...I took off both covers, but any adjustment control is
not blatantly obvious....
Scott
N0EDV
Scott,
I've seen the oven temperature control circuit more likely to cause
this type of problem. The fact that the oscillator is working
eliminates a lot of circuitry.


Before you do any more adjusting, do this:
Check that the oven temperature control circuit is working. Check to
see if the collector of Q1 is in the ballpark of about -21 volts.
That point should start out (cold oven) at around -5 volts or so,
and go toward -21 volts as the oven warms up. If it stays at the
lower voltage, you have a problem with either Q1 or one of the
transistors on the oven control assy A25. That same reasoning goes
if the voltage at Q1 collector starts out and stays at -35 volts or
so.
An extreme cause would be that of the oven heater being open. In
that case, the oven assembly is bad, and will need to be replaced.
You can attempt ot disassemble the oven and repair the heater, but
it's iffy. One of the temp sensor components inside the oven might
be bad as well.
If the oven and the oven control is OK, that means that the
oscillator is out of tune. That could be caused by the crystal
itself, of one of the capacitors inside the oven.


I have an operable oven assembly that we could make a deal on, but
since I recently moved from Florida to Alabama and don't have a shop
area yet, it's still in storage. If you can wait for a couple of
months, I could dig it out for you. You might look on Ebay for an
oven; I've seen them offerred there, but not often.


--
David
dgminala at mediacombb dot net
Excuse me for seeming a Patronising Old ******* here, but I feel some
basic radio theory is in order here, and to respond to the original
question......


Quote.
*I measure the signal coming out the back of the counter
(with another counter) at 10.000066 MHz.
Response.
How accurate is the frequency counter you are using to measure the
10Mhz TXCO? *(and does it have a current calibration certificate?) -
unless it is at least an order of magnitude BETTER than the HP, any
results will be meaningless. *Your comparing the HP ref. signal
to......what?....


A easier way is to zero beat the HP TXCO with WWV. Yes, for the
purists, there are problems with this method, (which are NOT relevant
here) but if you tune for zerobeat by ear as best you can - by then,
the S meter should be pulsating (it can see the beat note, you cant
hear it) and then tune.


Get really hi-tech, use a GPS locked counter.


And I hope you took notes of the original "frequency" and can take it
back to this. Its a well aged, ovenized xtal. It will be pretty bloody
close, unless someone has been into it before you.....


These things were, in their day, laboratory grade instruments. They
still are, but have been superseded as technology advanced. You need
to learn what the display is telling you, and how much is relevant to
what you do. Its unlikely that you will be building something that
needs 10-12 accuracy. (A nominal figure, not going to dig the manual
out to look)


The error you quote is totally insignificant for average amateur (and
most professional ) use.


If the oven is working, it will get warm. Simple.
Plot the frequency change from cold switch on - see how long it takes
to stabilise. Do it again, later, when the ambient room temperature
has changed. If no shift, its OK. And if it is not working......well,
they ARE fascinating instruments, the service manual a joy to read.
(Bout the size of the phone book) They even give Boolean equations for
it. *You could be entranced by 1960's technology - if you so choose.
g


Later model ones had a "Oven"light on the front panel - if it was out
after warm-up, then it was ok. BTW - anyone got a service manual for a
HP5248L counter.......got a gating fault, how similar are they to the
5245L - any HP test gurus out there?


In good faith, and hopefully no insult intended or received.


Andrew VK3BFA.


The 5248L manual is on Agilent's site at
http://cp.literature.agilent.com/lit...5248-90001.pdf. I can't say how
similar they are to the 5245L, but the DCUs seem to be the same. *I used to
be a calibration tech many years ago, and while I saw many of both
instruments on my bench, I rarely had to repair them; quite reliable. *I
remember two cases where the counters exhibited the exact problem the OP
has; significant oscillator error. *Both turned out to be problems with the
oven control circuit.


I have to disagree with your statement that the OP's error is insignigicant
for professional use. *That might be true for some hobbiest uses, but for
many amateur radio operators and certainly for professional use, *it's a
very significant error. * The original time base spec for the 5245L is
3x10^-9 per day.


The oven has been mentioned in a few posts. *I will try to establish if
that is working or if that's where the problem lays. *I want to use it
to count my 189.XXXXX MHz XTAL freq in my 10 GHz transverter. *I need
pretty good accuracy since this XTAL is multiplied by a factor of 54 in
the LO chain. *Thanks for the tip!

Scott
N0EDV


QST had an article on GPS frequency standard. Something you might want
to check into. I think it was a construction project.

Jimmie

Scott[_4_] April 28th 10 12:07 PM

HP 5245L Counter Oscillator adjust?
 
JIMMIE wrote:


QST had an article on GPS frequency standard. Something you might want
to check into. I think it was a construction project.

Jimmie



Well, it certainly shouldn't be too hard to do. I think the 5245L uses
a 1 MHz signal for the external timebase input, so it might just be a
matter of dividing the 10 MHz output signal that the GPSDOs that I'm
familiar with and supplying it to the external timebase input...


Fred McKenzie May 1st 10 09:07 PM

HP 5245L Counter Oscillator adjust?
 
In article ,
Scott wrote:

I measure the signal coming out the back of the counter
(with another counter) at 10.000066 MHz. I adjusted the "coarse tune"
adjustment on the back of the unit and this is as close as it gets to
10.000000 MHz, so I assume there must be some other adjustment
somewhere.


Scott-

I have a different HP counter that had a similar problem when I got it.
There was a capacitor adjustment in the crystal oven, but it did not
have enough range to bring the oscillator to 10.0 MHz.

It turned out that there was an open thermal fuse in the supply line
inside the crystal oven. It was a plug-in device about the size of a
half watt resistor, maybe smaller. There were two wire-sockets that its
leads plugged into.

I managed to buy the last thermal fuse HP had in stock at the time.
Before it arrived, I had fabricated replacements using a thermal fuse
from Radio Shack, wired in parallel with a high value resistor which had
the correct lead diameter to plug into the wire sockets.

Using a rubidium oscillator purchased on E-Bay, I aligned the repaired
oscillator fairly accurately using an oscilloscope. After several
years, it seems to still be within a fraction of one Hz!

It turns out that this is a common problem. I wrote it up and sent it
to QST for their Hints & Kinks several years back. Since then, one of
the HP designers of the oscillator posted a comment that the thermal
fuse wasn't really needed, since the heating element shouldn't cause any
damage if left on continuously. Even so, I feel better with the thermal
fuse installed!

Fred
K4DII

Fred McKenzie May 2nd 10 12:56 AM

HP 5245L Counter Oscillator adjust?
 
In article ,
Fred McKenzie wrote:

It turned out that there was an open thermal fuse in the supply line
inside the crystal oven. It was a plug-in device about the size of a
half watt resistor, maybe smaller. There were two wire-sockets that its
leads plugged into.


I dug out my notes to find out the specifics. My counter is an HP 5334B
with Option 1, the high stability oscillator. The oscillator is one of
the HP 10811 series. The original thermal fuse, F1, was rated for 108
degrees C. HP revised the part to one rated for 115 degrees C, part
number 2110-0617 (10811-80003).

The Radio Shack thermal fuse was 270-1322A, rated for 128 degrees C.
There is also an NTE Electronics NTE8115, "Thermal Cut-Off", rated for
117 degrees C. Either is larger than the HP part, and is a tight fit.
I wrapped them in electrical tape to protect against short circuits.
When soldering to the high-value resistors, I clamped the fuse leads in
a pair of pliers held with rubber bands.

Of course this may not apply to your counter if it doesn't have the
crystal oven!

Fred
K4DII

Scott[_4_] May 2nd 10 01:56 AM

HP 5245L Counter Oscillator adjust?
 
Fred McKenzie wrote:
In article ,
Scott wrote:

I measure the signal coming out the back of the counter
(with another counter) at 10.000066 MHz. I adjusted the "coarse tune"
adjustment on the back of the unit and this is as close as it gets to
10.000000 MHz, so I assume there must be some other adjustment
somewhere.


Scott-

I have a different HP counter that had a similar problem when I got it.
There was a capacitor adjustment in the crystal oven, but it did not
have enough range to bring the oscillator to 10.0 MHz.

It turned out that there was an open thermal fuse in the supply line
inside the crystal oven. It was a plug-in device about the size of a
half watt resistor, maybe smaller. There were two wire-sockets that its
leads plugged into.

I managed to buy the last thermal fuse HP had in stock at the time.
Before it arrived, I had fabricated replacements using a thermal fuse
from Radio Shack, wired in parallel with a high value resistor which had
the correct lead diameter to plug into the wire sockets.

Using a rubidium oscillator purchased on E-Bay, I aligned the repaired
oscillator fairly accurately using an oscilloscope. After several
years, it seems to still be within a fraction of one Hz!

It turns out that this is a common problem. I wrote it up and sent it
to QST for their Hints & Kinks several years back. Since then, one of
the HP designers of the oscillator posted a comment that the thermal
fuse wasn't really needed, since the heating element shouldn't cause any
damage if left on continuously. Even so, I feel better with the thermal
fuse installed!

Fred
K4DII


Thanks Fred! I haven't had time to dig into it yet as I'm out playing
on 10 GHz this weekend. Fortunately, I have a second 5245L for
comparisons. I did find the capacitor on the oven as you mention, but
it did not have enough range as you noted. If the heater is working,
does the enclosure get warm? Seems to me that as I was feeling around,
it was ice cold on the outside. Maybe we're onto something here!

Scott
N0EDV

Scott[_4_] May 2nd 10 01:58 AM

HP 5245L Counter Oscillator adjust?
 
Fred McKenzie wrote:
In article ,
Fred McKenzie wrote:

It turned out that there was an open thermal fuse in the supply line
inside the crystal oven. It was a plug-in device about the size of a
half watt resistor, maybe smaller. There were two wire-sockets that its
leads plugged into.


I dug out my notes to find out the specifics. My counter is an HP 5334B
with Option 1, the high stability oscillator. The oscillator is one of
the HP 10811 series. The original thermal fuse, F1, was rated for 108
degrees C. HP revised the part to one rated for 115 degrees C, part
number 2110-0617 (10811-80003).

The Radio Shack thermal fuse was 270-1322A, rated for 128 degrees C.
There is also an NTE Electronics NTE8115, "Thermal Cut-Off", rated for
117 degrees C. Either is larger than the HP part, and is a tight fit.
I wrapped them in electrical tape to protect against short circuits.
When soldering to the high-value resistors, I clamped the fuse leads in
a pair of pliers held with rubber bands.

Of course this may not apply to your counter if it doesn't have the
crystal oven!

Fred
K4DII


Yes, mine has the oven (and the high stability Oscillator option). I've
gotten some good leads on this problem, so when I get a bit more time,
I'll rip into it! Thanks again!!

Scott
N0EDV

Bill Janssen May 2nd 10 02:17 AM

HP 5245L Counter Oscillator adjust?
 
Fred McKenzie wrote:
In article ,
Scott wrote:


I measure the signal coming out the back of the counter
(with another counter) at 10.000066 MHz. I adjusted the "coarse tune"
adjustment on the back of the unit and this is as close as it gets to
10.000000 MHz, so I assume there must be some other adjustment
somewhere.


Scott-

I have a different HP counter that had a similar problem when I got it.
There was a capacitor adjustment in the crystal oven, but it did not
have enough range to bring the oscillator to 10.0 MHz.

It turned out that there was an open thermal fuse in the supply line
inside the crystal oven. It was a plug-in device about the size of a
half watt resistor, maybe smaller. There were two wire-sockets that its
leads plugged into.

I managed to buy the last thermal fuse HP had in stock at the time.
Before it arrived, I had fabricated replacements using a thermal fuse
from Radio Shack, wired in parallel with a high value resistor which had
the correct lead diameter to plug into the wire sockets.

Using a rubidium oscillator purchased on E-Bay, I aligned the repaired
oscillator fairly accurately using an oscilloscope. After several
years, it seems to still be within a fraction of one Hz!

It turns out that this is a common problem. I wrote it up and sent it
to QST for their Hints & Kinks several years back. Since then, one of
the HP designers of the oscillator posted a comment that the thermal
fuse wasn't really needed, since the heating element shouldn't cause any
damage if left on continuously. Even so, I feel better with the thermal
fuse installed!

Fred
K4DII

Scott
I seem to recall that there is a second adjustment inside the plug-in
area. I assume you found
both of the adjustments.

Bill K7NOM

Scott[_4_] May 3rd 10 11:54 AM

HP 5245L Counter Oscillator adjust?
 
Bill Janssen wrote:
Fred McKenzie wrote:
In article ,
Scott wrote:


I measure the signal coming out the back of the counter (with another
counter) at 10.000066 MHz. I adjusted the "coarse tune" adjustment
on the back of the unit and this is as close as it gets to 10.000000
MHz, so I assume there must be some other adjustment somewhere.


Scott-

I have a different HP counter that had a similar problem when I got
it. There was a capacitor adjustment in the crystal oven, but it did
not have enough range to bring the oscillator to 10.0 MHz.

It turned out that there was an open thermal fuse in the supply line
inside the crystal oven. It was a plug-in device about the size of a
half watt resistor, maybe smaller. There were two wire-sockets that
its leads plugged into.

I managed to buy the last thermal fuse HP had in stock at the time.
Before it arrived, I had fabricated replacements using a thermal fuse
from Radio Shack, wired in parallel with a high value resistor which
had the correct lead diameter to plug into the wire sockets.

Using a rubidium oscillator purchased on E-Bay, I aligned the repaired
oscillator fairly accurately using an oscilloscope. After several
years, it seems to still be within a fraction of one Hz!

It turns out that this is a common problem. I wrote it up and sent it
to QST for their Hints & Kinks several years back. Since then, one of
the HP designers of the oscillator posted a comment that the thermal
fuse wasn't really needed, since the heating element shouldn't cause
any damage if left on continuously. Even so, I feel better with the
thermal fuse installed!

Fred
K4DII

Scott
I seem to recall that there is a second adjustment inside the plug-in
area. I assume you found
both of the adjustments.

Bill K7NOM


I did see a fairly large air variable capacitor sitting next to the oven
assembly, but since I didn't know what it was for, I didn't adjust it.
I'll go through the manual I downloaded and see if I can get it on
frequency. Thanks for the note.

Scott
N0EDV

Dave M[_3_] May 3rd 10 06:03 PM

HP 5245L Counter Oscillator adjust?
 
Scott wrote:
Bill Janssen wrote:
Fred McKenzie wrote:
In article ,
Scott wrote:


I measure the signal coming out the back of the counter (with
another counter) at 10.000066 MHz. I adjusted the "coarse tune"
adjustment on the back of the unit and this is as close as it gets
to 10.000000 MHz, so I assume there must be some other adjustment
somewhere.

Scott-

I have a different HP counter that had a similar problem when I got
it. There was a capacitor adjustment in the crystal oven, but it did
not have enough range to bring the oscillator to 10.0 MHz.

It turned out that there was an open thermal fuse in the supply line
inside the crystal oven. It was a plug-in device about the size of
a half watt resistor, maybe smaller. There were two wire-sockets
that its leads plugged into.

I managed to buy the last thermal fuse HP had in stock at the time.
Before it arrived, I had fabricated replacements using a thermal
fuse from Radio Shack, wired in parallel with a high value resistor
which had the correct lead diameter to plug into the wire sockets.

Using a rubidium oscillator purchased on E-Bay, I aligned the
repaired oscillator fairly accurately using an oscilloscope. After
several years, it seems to still be within a fraction of one Hz!

It turns out that this is a common problem. I wrote it up and sent
it to QST for their Hints & Kinks several years back. Since then,
one of the HP designers of the oscillator posted a comment that the
thermal fuse wasn't really needed, since the heating element
shouldn't cause any damage if left on continuously. Even so, I
feel better with the thermal fuse installed!

Fred
K4DII

Scott
I seem to recall that there is a second adjustment inside the plug-in
area. I assume you found
both of the adjustments.

Bill K7NOM


I did see a fairly large air variable capacitor sitting next to the
oven assembly, but since I didn't know what it was for, I didn't
adjust it. I'll go through the manual I downloaded and see if I can
get it on frequency. Thanks for the note.

Scott
N0EDV


Scott,
Those capacitors inside the plugin bay are medium and fine frequency
adjustments. If the coarse frequency adjustment inside the oven won't get
it on frequency, then the others certainly won't have enough range to get it
right.
As I and others have suggested, you really need to verify whether the oven
is being heated before you do any more adjusting. Set the coarse tuning
back to its starting position and troubleshoot the oven circuitry. I'm
convinced that's where you'll find the trouble.
Get your voltmeter out and check the oven heater connection. It will tell
you a lot.
--
David
dgminala at mediacombb dot net




K7ITM May 3rd 10 10:37 PM

HP 5245L Counter Oscillator adjust?
 
On May 1, 5:56*pm, Scott wrote:
Fred McKenzie wrote:
In article ,
*Scott wrote:


I measure the signal coming out the back of the counter
(with another counter) at 10.000066 MHz. *I adjusted the "coarse tune"
adjustment on the back of the unit and this is as close as it gets to
10.000000 MHz, so I assume there must be some other adjustment
somewhere.


Scott-


I have a different HP counter that had a similar problem when I got it.
There was a capacitor adjustment in the crystal oven, but it did not
have enough range to bring the oscillator to 10.0 MHz.


It turned out that there was an open thermal fuse in the supply line
inside the crystal oven. *It was a plug-in device about the size of a
half watt resistor, maybe smaller. *There were two wire-sockets that its
leads plugged into.


I managed to buy the last thermal fuse HP had in stock at the time. *
Before it arrived, I had fabricated replacements using a thermal fuse
from Radio Shack, wired in parallel with a high value resistor which had
the correct lead diameter to plug into the wire sockets.


Using a rubidium oscillator purchased on E-Bay, I aligned the repaired
oscillator fairly accurately using an oscilloscope. *After several
years, it seems to still be within a fraction of one Hz!


It turns out that this is a common problem. *I wrote it up and sent it
to QST for their Hints & Kinks several years back. *Since then, one of
the HP designers of the oscillator posted a comment that the thermal
fuse wasn't really needed, since the heating element shouldn't cause any
damage if left on continuously. *Even so, I feel better with the thermal
fuse installed!


Fred
K4DII


Thanks Fred! *I haven't had time to dig into it yet as I'm out playing
on 10 GHz this weekend. *Fortunately, I have a second 5245L for
comparisons. *I did find the capacitor on the oven as you mention, but
it did not have enough range as you noted. *If the heater is working,
does the enclosure get warm? *Seems to me that as I was feeling around,
it was ice cold on the outside. *Maybe we're onto something here!

Scott
N0EDV


Yes, most certainly the oven should be noticeably warm, unless your
ambient temperature is already really hot. You can also monitor the
current the oven draws (perhaps with some difficulty, depending on how
the oven is wired into the circuit). You should see moderately high
current when the oven is first turned on, and the current should drop
to (very roughly) half as much as the oven reaches operating
temperature. I'd expect the oven control loop to be reasonably
damped, so the current falls from the startup value to the idling
value within just a few seconds and stabilizes without overshoot, or
with only minor overshoot. At least that's what I've seen on several
models, including the HP10811.

These days, you can get some remarkably small and low-power oven
oscillators, down to TO-5 transistor can size I believe, and possibly
even smaller. The power to run them is low milliwatts. Even
temperature-compensated oscillators have gotten remarkably good...I
have some 3x5 millimeter ones that are rated half a part per million
max deviation over -20C to +55C (and run on about 2.5 milliwatts), and
you can get better than that.

Cheers,
Tom

Scott[_4_] May 5th 10 12:13 AM

HP 5245L Counter Oscillator adjust?
 
Dave M wrote:


Scott,
Those capacitors inside the plugin bay are medium and fine frequency
adjustments. If the coarse frequency adjustment inside the oven won't get
it on frequency, then the others certainly won't have enough range to get it
right.
As I and others have suggested, you really need to verify whether the oven
is being heated before you do any more adjusting. Set the coarse tuning
back to its starting position and troubleshoot the oven circuitry. I'm
convinced that's where you'll find the trouble.
Get your voltmeter out and check the oven heater connection. It will tell
you a lot.


Yup...I will delve into the oven circuitry when I get a chance...have a
couple other higher priority projects to clean up first...

N0EDV

Scott[_4_] May 5th 10 12:18 AM

HP 5245L Counter Oscillator adjust?
 
K7ITM wrote:


Yes, most certainly the oven should be noticeably warm, unless your
ambient temperature is already really hot. You can also monitor the
current the oven draws (perhaps with some difficulty, depending on how
the oven is wired into the circuit). You should see moderately high
current when the oven is first turned on, and the current should drop
to (very roughly) half as much as the oven reaches operating
temperature. I'd expect the oven control loop to be reasonably
damped, so the current falls from the startup value to the idling
value within just a few seconds and stabilizes without overshoot, or
with only minor overshoot. At least that's what I've seen on several
models, including the HP10811.

These days, you can get some remarkably small and low-power oven
oscillators, down to TO-5 transistor can size I believe, and possibly
even smaller. The power to run them is low milliwatts. Even
temperature-compensated oscillators have gotten remarkably good...I
have some 3x5 millimeter ones that are rated half a part per million
max deviation over -20C to +55C (and run on about 2.5 milliwatts), and
you can get better than that.

Cheers,
Tom


I don't think it's POSSIBLE to get REALLY HOT here in WI (by some
standards, that is...to me, 75 is really hot!)

;)