LinkBack Thread Tools Search this Thread Display Modes
Prev Previous Post   Next Post Next
  #11   Report Post  
Old December 5th 03, 03:37 PM
Ian Buckner
 
Posts: n/a
Default


"Paul Burridge" wrote in message
...
On 4 Dec 2003 17:30:27 -0800, Winfield Hill
wrote:

As John has said, that's a very low inductance that should not
present any problems at such a low power level. But perhaps for
a more detailed answer you can tell us the frequencies your coil
will experience. At high frequencies skin and proximity effects
dominate, and these can be evaluated with an Rac/Rdc ratio. If
a ferrite is used its high-frequency core loss can also be modeled
as an inductor resistance.


Thanks, Win! You're a diamond. John's formulae didn't appear on his
post for some reason, but you've given me the info I need to start
winding and be slap in the ball park right away. Great.
BTW, the factory inductors I have already are only about the size of
the newest half-watt resistors, so I was reluctant to chance it. I
know things keep getting smaller and somehow seem to defy the laws

of
physics, but just call me old fashioned. :-)
Thanks again.

P.


--

"I expect history will be kind to me, since I intend to write it."
-

Winston Churchill

Paul, I really don't think you need to wind your own. For example,
a Coilcraft 1008CS 180nH part is rated at 620mA rms:

http://www.coi1craft.com/1008cs.cfm

The "trick" is that the dissipation is a function of the series
resistance, which is very low (0.77 ohms) as long as the core
doesn't saturate.

If you want to get really silly, their "Spring" inductors are rated
at 3A rms.

Regards
Ian


 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Coils or specifications needed for Heathkit GD-1B Grid Dip Meter. Bob Equipment 9 August 15th 04 02:42 PM
Coils or specifications needed for Heathkit GD-1B Grid Dip Meter. Bob Equipment 0 August 12th 04 08:36 AM
Coils or specifications needed for Heathkit GD-1B Grid Dip Meter. Bob Equipment 0 August 12th 04 08:36 AM
National SW-3 coil winding data John H. Gindlesberger Boatanchors 0 March 17th 04 07:00 PM
phasing coils Antenna 2 July 25th 03 04:06 AM


All times are GMT +1. The time now is 04:20 AM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017