Rigth, I have seen that info, (0.01% of center freqency + 2% of freqency
span + 5 x N MHz), but I quite don't understand it ... If say I am measuring a 300 Mhz signal, and I have a span of say 500 Khz.. - What is the precision or error that I can expect ? Any hands on experience with that spectrum analizer, and in special regarding frecuency marker precision, will be welcomed. Salva "Norm Mann" escribió en el mensaje news:JeYmf.9018$Ea6.4054@trnddc08... "Salvador Ferrairo" wrote in message ... Hi I am using a HP8592B to do RF measurements and the marker, after a passed auto calibration, could be out 100 or 150 khz when measuring signals over the 300Mhz range. This spectrum analiser is a non synthetised VCO type, and I don't quite know what frecuency measurement precision can be expected from it. - Any experience on the marker frecuency precision on that type of spectrum analiser? Looking in a 1991 HP catalog, I see that you can expect a readout accuracy of no better than 0.01% of center freqency + 2% of freqency span + 5 x N MHz (this appears to be a term for the timebase accuracy). Keep in mind that many spectrum analyzers are not precision measurement instruments. -NM |