shielded multiway connector
Hi,
I am using an LMS485 chips to send a differential 1MHz clock to multiple PLL's via twisted screened cable. Does anyone know of a screened small 2 way connector I could use on my PCB for this? Thanks, John. |
shielded multiway connector
Hirose make lots of small shielded connectors that should be fine for
1MHz. They aren't cheap. Unless you are operating in a particularly noisy environment, though, I wonder why you couldn't just use a three or four pin header (ground on just one side or in the middle, or symmetrical ground on each side). Will you be connecting and disconnecting them often, or is it more a set-and-forget application? Have you done any phase noise testing on the LMS485? I'm wondering how well they work for precision clock distribution. It's an interesting idea. We find that ECL keeps close-in phase noise quite low, and could drive the usual 100-ohm-differential RS485 bus, at least singly-terminated. Cheers, Tom |