dick on the langwang May 26th 06 04:01 PM

Repairing moving coil meters.
 
Has anyone experience of repairing moving coil meters and/or able give
me to any useful pointers. One of my (many !!) restoration projects is
being held up by an u/s meter & from inspection I suspect although the
coil/pointer move freely one of the fine wire connections to the coil
has gone open circuit, due to corrosion. I'm happy stripping down &
repairing clocks but have no experience of doing the same to meters. In
the end I'll probably have to find a replacement but it would be nice
to try & get the original meter working again.


Fred McKenzie May 26th 06 07:08 PM

Repairing moving coil meters.
 
In article .com, "dick
on the langwang" wrote:

Has anyone experience of repairing moving coil meters and/or able give
me to any useful pointers. One of my (many !!) restoration projects is
being held up by an u/s meter & from inspection I suspect although the
coil/pointer move freely one of the fine wire connections to the coil
has gone open circuit, due to corrosion. I'm happy stripping down &
repairing clocks but have no experience of doing the same to meters. In
the end I'll probably have to find a replacement but it would be nice
to try & get the original meter working again.


Dick-

As I recall, current is conducted via upper and lower springs, to the
moving coil. If you can determine that the coil itself is still
conducting, you may be able to repair connections to the other components.

If the needle cannot be zeroed with the mechanical adjustment, it is
possible one of the springs has broken or come loose at one end.

It would be handy if you have an Ohmmeter with a beeper, that sounds with
very low current conduction.

(I've had very few movements with open coils, but have obversed several
cases where plating of the pole pieces peeled and jammed the movement.)

As far as replacement, look near the bottom of the meter scale. You may
find the meter sensitivity listed. It might be something like "FS=1mA" or
"FS=50uA". If you determine the sensitivity, any meter with the same size
and sensitivity may be useable by swapping meter scales.

Fred
K4DII

dick on the langwang May 27th 06 10:31 AM

Repairing moving coil meters.
 
Already know the sensitivity (250 microamps) but thanks for the tip
about peeling pole piece plating, don't think it's that though because
the coil/needle rotate freely. Reason I suspect the o/c is because
there's a 'green, furry blob' (due damp storage sometime in the past ?)
halfway along the fine coil connection wire, possibly surrounding a
joint. Job for a fine brush & steady hand I think !!


John Ferrell May 27th 06 08:16 PM

Repairing moving coil meters.
 
I have not worked on a meter movement in many years due to lower costs
replacements and better personal finances. When I did work on them I
recall being pretty successful.
If you spend enough time preparing, it almost always works out. The
safest way to verify an open movement is to take it in your hand and
see how much you can shake it around. If the needle shows a difference
in damping with and without the terminals shorted it is not open.

Bearing problems due to mechanical shock are common.

Broken pointers can be repaired with a tiny droplet of black paint.
Use a single hair from a paint brush to apply.

Be innovative, if you are motivated, it will work!

de W8CCW John

On 26 May 2006 08:01:20 -0700, "dick on the langwang"
wrote:

Has anyone experience of repairing moving coil meters and/or able give
me to any useful pointers. One of my (many !!) restoration projects is
being held up by an u/s meter & from inspection I suspect although the
coil/pointer move freely one of the fine wire connections to the coil
has gone open circuit, due to corrosion. I'm happy stripping down &
repairing clocks but have no experience of doing the same to meters. In
the end I'll probably have to find a replacement but it would be nice
to try & get the original meter working again.

John Ferrell W8CCW

fsphotos April 26th 12 11:21 PM

I bought a Triplett 630 on eBay that has a problem with its needle swinging even with the most gentle movement. When you handle the meter the needle swings back and forth and takes a while to settle down. Any suggestion on what is causing the needle to swing so freely? Can it be be adjusted? Appreciate any help.

Quote:

Originally Posted by dick on the langwang (Post 437866)
Has anyone experience of repairing moving coil meters and/or able give
me to any useful pointers. One of my (many !!) restoration projects is
being held up by an u/s meter & from inspection I suspect although the
coil/pointer move freely one of the fine wire connections to the coil
has gone open circuit, due to corrosion. I'm happy stripping down &
repairing clocks but have no experience of doing the same to meters. In
the end I'll probably have to find a replacement but it would be nice
to try & get the original meter working again.



All times are GMT +1. The time now is 09:52 AM.