WTP07 October 5th 04 11:25 PM

PRO 95 TRUNKED SYSTEM
 
Can anyone tell me what type of trunked system a "GE" system is? Motorola?
EDACS?

Thanks...

Randy.




Gerry Wheeler October 6th 04 01:25 AM

On Tue, 05 Oct 2004 18:25:32 -0400, WTP07 wrote:

Can anyone tell me what type of trunked system a "GE" system is?
Motorola? EDACS?


Not Motorola -- they're longtime competitors.

I think GE is equivalent to EDACS, but I'm open to correction. I heard the
long story once about who developed what, and then who bought whom, and
all that. As I recall, the net result is that GE was involved in EDACS.
--
Gerry Wheeler
Naples, FL


WTP07 October 6th 04 01:59 AM

Thanks Gerry,

The learning curve with my "new to me" PRO 95 is pretty steep....

having a hard time with picking up the trunking end of things. I keep
getting the squacking...and very infrequently...voice! I really wish I
could find an extensive trunking tutorial...

Randy.


"Gerry Wheeler" wrote in message
. ..
On Tue, 05 Oct 2004 18:25:32 -0400, WTP07 wrote:

Can anyone tell me what type of trunked system a "GE" system is?
Motorola? EDACS?


Not Motorola -- they're longtime competitors.

I think GE is equivalent to EDACS, but I'm open to correction. I heard the
long story once about who developed what, and then who bought whom, and
all that. As I recall, the net result is that GE was involved in EDACS.
--
Gerry Wheeler
Naples, FL




Bruce Markowitz October 6th 04 02:59 AM

You need to set the bank and the channels to ED
AND
EDACS channels must be loaded in the proper order, starting with the bank
"01" channel, "00" must be locked out
"WTP07" wrote in message
. ..
Thanks Gerry,

The learning curve with my "new to me" PRO 95 is pretty steep....

having a hard time with picking up the trunking end of things. I keep
getting the squacking...and very infrequently...voice! I really wish I
could find an extensive trunking tutorial...

Randy.


"Gerry Wheeler" wrote in message
. ..
On Tue, 05 Oct 2004 18:25:32 -0400, WTP07 wrote:

Can anyone tell me what type of trunked system a "GE" system is?
Motorola? EDACS?


Not Motorola -- they're longtime competitors.

I think GE is equivalent to EDACS, but I'm open to correction. I heard

the
long story once about who developed what, and then who bought whom, and
all that. As I recall, the net result is that GE was involved in EDACS.
--
Gerry Wheeler
Naples, FL






Paul Hirose October 6th 04 07:17 PM

WTP07 wrote:
having a hard time with picking up the trunking end of things. I keep
getting the squacking...and very infrequently...voice! I really wish I
could find an extensive trunking tutorial...


If you tell us what department you're trying to monitor and what you
know about their freqs etc., maybe someone can help with scanner
setup. As I write this my PRO-95 is simultaneously scanning EDACS and
Motorola trunked systems, as well as multiple conventional channels.
The radio is competent, but its manual is poorly organized. That
reminds me, I should finish the critique of the PRO-95 that I started
a couple months ago.

Try putting stuff like "trunking scanner", "trunked radio", etc. into
a search engine. It should come up with some useful pages.

--

Paul Hirose
To reply by email delete INVALID from address.


Paul Hirose October 8th 04 03:35 AM

WTP07 wrote:

1) I have 2 "sets" of freq's....140ish Mhz and 800ish Mhz. Does this seem
right? (these are for the London ONT cops)


The official site says they're using a "3 site, 20 channel, 800
megahertz trunking system", so I'd recommend the 800 MHz freqs.

http://police.city.london.on.ca/Tech...ioOverview.htm


3) The manual states that with EDACS systems, the channels have to be in LCN
(logical channel number) order. Is this simply in order by frequency # or
is there another way to determine the LCN?


The LCNs aren't necessarily arranged in order of frequency. If you
don't know the LCN assignments it's possible to determine them by
trial and error.


2) I seem to have 2 800 Mhz control channels (CTL-01 and CTL-02 on the
display)


If a control channel is active, the CTL-01 or CTL-02 should be
intermittently replaced by talkgroup numbers when users are talking on
the system. Do you see that?

The other freqs -- do they sound like they're trunked and part of the
same system? Park the scanner on each one for a while and listen. Are
you hearing voice? The web site says the system was designed to allow
digital encrypted voice. The PRO-95 can't handle digital voice, even
when sent "in the clear".

--

Paul Hirose
To reply by email delete INVALID from address.