Regarding Acoustic Echo Cancellation with Subbanding
Dear Sir,
I am working on Acoustic Echo Cancellation. I have implemented both AEC without subbanding and AEC with subbanding in C+ +. For subbanding of AEC I used Polyphase IIR filter(with 70dB attenuation). AEC without subbanding is working fine. But in the outputs of AEC with subbanding there exists some slight disturbance(but echo is cancelling for all recorded audio files that are recorded through sound recorder and for some other audio files that I got from some application echo is not cancelling and this disturbance is continued). So I obsereved each function(ie., polyphase lowpass filter function, polyphase highpass filter function and the AEC operation function) output by printing each and every output value of functions in text files. In that I observed that where ever the highpass filter farend sample is negative(there by estimated echo is negative and hence and updated weights of that sample are negative) this distortion is occuring. So how to handle when updated weights are negative so that to get clear echo cancelled outputs. If any one knows information regarding this please reply to this mail. Thanks in advance. Regards, Aparna Ram.K. |
Regarding Acoustic Echo Cancellation with Subbanding
"Aparna Ram" wrote in message oups.com... Dear Sir, I am working on Acoustic Echo Cancellation. I have implemented both AEC without subbanding and AEC with subbanding in C+ +. For subbanding of AEC I used Polyphase IIR filter(with 70dB attenuation). AEC without subbanding is working fine. But in the outputs of AEC with subbanding there exists some slight disturbance(but echo is cancelling for all recorded audio files that are recorded through sound recorder and for some other audio files that I got from some application echo is not cancelling and this disturbance is continued). So I obsereved each function(ie., polyphase lowpass filter function, polyphase highpass filter function and the AEC operation function) output by printing each and every output value of functions in text files. In that I observed that where ever the highpass filter farend sample is negative(there by estimated echo is negative and hence and updated weights of that sample are negative) this distortion is occuring. So how to handle when updated weights are negative so that to get clear echo cancelled outputs. If any one knows information regarding this please reply to this mail. Thanks in advance. Regards, Aparna Ram.K. Yes, I believe we can help. Post your source code and we can get started. -- rb |
Regarding Acoustic Echo Cancellation with Subbanding
In article .com,
Aparna Ram wrote: Dear Sir, I am working on Acoustic Echo Cancellation. Snip How exciting. -- Telamon Ventura, California |
Regarding Acoustic Echo Cancellation with Subbanding
In article ,
"Ron Baker, Pluralitas!" wrote: "Aparna Ram" wrote in message oups.com... Dear Sir, I am working on Acoustic Echo Cancellation. Snip Yes, I believe we can help. Post your source code and we can get started. Have him email you then. -- Telamon Ventura, California |
All times are GMT +1. The time now is 05:09 PM. |
Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
RadioBanter.com