Richard Clark
Posts: n/a
On 11 Aug 2003 09:54:47 -0700,
(Tom Bruhns) wrote:
In such a case, I'd work on a match to the antenna (or
the Cantenna or whatever) first--well, right after making sure the
meter was telling me the truth or something close to it.
Hi Tom,
This is kind of a chicken and egg problem.
Calibrate the meter against the load.
Calibrate the load against the meter.
It would seem that discussion would eventually get around to bringing
in a known and stable reference. The length of lossy line would
suffice for a rough cut solution but still leaves a bench full of
rather sloppy instruments.
73's
Richard Clark, KB7QHC
Reply With Quote