Thread: VE9SRB
View Single Post
  #15   Report Post  
Old June 3rd 04, 08:44 PM
Jim Kelley
 
Posts: n/a
Default



Cecil Moore wrote:

Walter Maxwell wrote:
Cecil, the following is a direct quote from Steve's Comm Quart Article, Oct
1999:
"For the impedance matching network to 'work', this analysis must demonstrate
that the steady-state traveling backward power developed at the matching network
input is equal in magnitude but 180 degrees out of phase with the initial power
reflected at the matching network input. For this to occur Vback must be the
negative of VR. In this case ALL POWER TRAVELING BACKWARD TOWARDS THE
TRANSMISTTER WILL BE CANCELED, resulting in the steady-state matched condition."


Joules/sec possesses phase? Joules/sec can be canceled?


Therein lies part of the problem with thinking that the unit
(Joules/sec) moves along a transmission line. Energy in Joules moves.
(Joules/sec) of power does not.

73, Jim AC6XG