Volker Tonn wrote:
But for sure you can not do it by yourself and it will cost a LOT. And
at least there is NO insurance it will work under ALL circumstances.
Best (additional) way to go is to disconnect the antenna when leaving
the shack or lightning is coming up whilst you are in your shack.


Not true. You have to be anal-retentive as hell to make sure that it
is done right, but you can do it properly using the right equipment.
Polyphaser or I.C.E. protectors do the job well, but they must be
mounted on an appropriate ground window. The object of the game is
not to have your equipment at ground potential; rather the object is
to have the potential on all the equipment rise and fall together so
there is no differential amongst the equipment.

There is quite a bit of introductory material at www.polyphaser.com.

Eric

--