On Fri, 04 Mar 2005 16:47:05 GMT, "Thomas Magma"
wrote:
Response is flattened through gain controlling the pre-amp from a look-up
table held in the micro's EEPROM. The alignment procedure is automated using
the HB-IP bus from the spectrum analyzer and a computer. The
computer/analyzer also looks for harmonic content and spurious emissions
during this procedure. Think it takes about ten seconds to do this.
Hi Thomas,
10 seconds to adjust all 6 stubs?
73's
Richard Clark, KB7QHC
|