wrote:

would a voltage balun be more effective in any of those conditions?


Hi Jack,

The typical Voltage BalUn is constructed in such a way that one lead
violates the isolation offered by the Current BalUn method. There are
examples found for the same application of the 4:1. One is the
Guanella, the other is the Ruthroff. If you examine the Ruthroff
model, you will notice that one lead of the load (antenna) is
connected directly to the source without a choking intervention. On
the other hand, both leads are choked by the Guanella.

By common usage, the Guanella is generally described as a Current
type, where as the Ruthroff is described as a Voltage type BalUn.
Current or Voltage, the more important feature is in the choking.

73's