John Smith wrote:
Cecil:

One element I do not understand in EZNEC is: say I end up with 225 ohms
inductive reactance in the gamma rod(just an example figure, use any you
please), how do I inform EZNEC I am inserting a 225 ohm capactive reactance,
at the feedpoint to offset it?


Use the "Loads" feature to install a lumped point load of
any Q. For instance, a coil might be 10 + j300 ohms or
a cap might be 2 - j500 ohms. The position of a load
is similar to positioning a source.
--
73, Cecil http://www.qsl.net/w5dxp