John Smith wrote:
Cecil:
One element I do not understand in EZNEC is: say I end up with 225 ohms
inductive reactance in the gamma rod(just an example figure, use any you
please), how do I inform EZNEC I am inserting a 225 ohm capactive reactance,
at the feedpoint to offset it?
Use the "Loads" feature to install a lumped point load of
any Q. For instance, a coil might be 10 + j300 ohms or
a cap might be 2 - j500 ohms. The position of a load
is similar to positioning a source.
--
73, Cecil
http://www.qsl.net/w5dxp
----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==----
http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups
----= East and West-Coast Server Farms - Total Privacy via Encryption =----