View Single Post
  #10   Report Post  
Old May 24th 05, 08:03 PM
Ron Hardin
 
Posts: n/a
Default

I run everything off a SS-18 (R8B and 30 ANC4's DA100E's and DSP's). I tried
a RS-7A but didn't like the heat it throws off. The switching supply avoids
that.

I fuse the output at the supply with an inline fuse (reflecting the wire
gauge), and fuse each device separately with like 1/4 or 1/2 or 1-2 amp fuses
where I distribute 12v to them all. A properly working power supply can easily
burn up the light wires running to these things if you don't fuse it, where
the internal resistance of wall warts had prevented it before you went to
a central power supply.

There's some birdies from the SS-18 but they're not bad; and I put the thing
in the basement and run the 12v to the first floor, so there's some distance
intervening as well. It does run enormously cooler.

I was motivated to get the central 12v by the heat the R8B's supply throws
off, that is now eliminated, as well as the growing number of wall warts
I was accumulating as I added to my phased array.
--
Ron Hardin


On the internet, nobody knows you're a jerk.