Wes Stewart wrote:
On 18 Jun 2005 14:20:34 -0700,
wrote:
[snip]
Rho can never be greater than one going into a passive
network. Only when you have an active device, or gain, can
you move outside of the unity circle on the Smith Chart.
You better raise your deflection shield.
No need to, i have the laws of physics
on my side!
Hint: Conservation of Energy!
Slick