View Single Post
  #20   Report Post  
Old June 27th 05, 02:28 PM
Cecil Moore
 
Posts: n/a
Default

W8JI wrote:
I'd like to clarify Sevik used transmission line mode, not transformer
mode coupling, in his single core 4:1 current balun. My contention is
it is impossible to build a 4:1 current balun on a single core unless
it is a primary-secondary isolation transformer, and an isolation
transformer would be a very limited performance balun compared to a
properly constructed transmission line balun.


Just so we know which Sevik design you are talking about, is it
Fig 9-8(B) of "Transmission Line Transformers"?
--
73, Cecil http://www.qsl.net/w5dxp

----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==----
http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups
----= East and West-Coast Server Farms - Total Privacy via Encryption =----