On Tue, 28 Jun 2005 23:17:15 -0500, Cecil Moore
wrote in :

Frank Gilliland wrote:
Impedance matching of an SWR meter is generally unimportant since most
SWR meters used for HF have a directional coupler that is much shorter
than the operating wavelength.


Point is that they are usually calibrated for Z0=50 ohms
and are in error when used in Z0 environments differing
from Z0=50 ohms, e.g. Z0=75 ohms.



The point is that the error is insignificant when the directional
coupler is much shorter than the wavelength. The error is even more
insignificant when there are a host of variables and confounds between
the SWR meter and the transmitted field that can (and frequently do)
affect the objective -- field strength. It's much simpler (and just
plain logical) to measure the field strength directly instead of
measuring an abstract value halfway towards the objective and relying
on nothing more than speculation that the rest is working according as
expected.