Frank Gilliland wrote:
Point is that they are usually calibrated for Z0=50 ohms
and are in error when used in Z0 environments differing
from Z0=50 ohms, e.g. Z0=75 ohms.


The point is that the error is insignificant when the directional
coupler is much shorter than the wavelength.


Nope, that's not the point at all. It is true that a 50 ohm
SWR meter designed for HF may not work on 70 cm but the error
I'm talking about is the calibration error in a 50 ohm SWR meter
designed for HF and used on HF in, for instance, a Z0 = 450 ohm
environment instead of its calibrated-for 50 ohm environment. It
works perfectly in a 50 ohm environment at the HF frequency of
operation. Here's the proof using a 50 ohm SWR meter:

XMTR--1/2WL 450 ohm line--SWR meter--1/2WL 450 ohm line--50 ohm load

The 50 ohm SWR meter will read 1:1, nowhere near the actual SWR

XMTR--1/4WL 450 ohm line--SWR meter--1/4WL 450 ohm line--50 ohm load

The 50 ohm SWR meter will read 81:1, nowhere near the actual SWR

An SWR meter calibrated for 450 ohms will correctly read 9:1
in both cases.
--
73, Cecil http://www.qsl.net/w5dxp