View Single Post
  #1   Report Post  
Old March 7th 04, 08:33 PM
Mike Knudsen
 
Posts: n/a
Default Resonant HV Secondary Windings?

This may be OT but could apply to some high-voltage transformers that supply
hihg-powered TX finals.

Does anyone know why the 4 KV secondary of a medium-sized transformer used in
an electrostatic precipitator air cleaner should have a 0.01 uF cap across its
secondary? My suppy failed when this cap opened up. Without it, only a small
fraction of the voltage was developed across the two diodes and 0.08 filter
caps in a voltage-doubler circuit that produces about 8 KV at up to 5 mA.

When I replaced it with half the original value, a 0.047 6KV cap from an old
color TV parts bin, I got enough DC output to draw a 1/4" arc. But when I
paralleld a second such cap, to pretty much equal the original value, I got a
3/8" or more arc, and the transformer made buzzing noises like it was really
doing some work.

I permenently soldered in the two replacement caps and put the air cleaner back
together. It works good as new again. Oh yes, I added a fuse to the primary
side, just in case my new caps short out. Odd there wasn't one already.

Anyway, I at first thought that shunt cap was just to protect against line
spikes, but apparently it tunes a resonance in the secondary winding, or
something. Has anyone else encountered such a cap? Obviously a dangerous
place for a cap to be, so I can understand this isn't used often. 73, Mike K.

Oscar loves trash, but hates Spam! Delete him to reply to me.