View Single Post
  #2   Report Post  
Old August 22nd 05, 03:42 AM
gb
 
Posts: n/a
Default

"Jack" wrote in message
...
I'm looking for the inductance and current rating of the HQ-180A power
supply choke so I can find a suitable replacement. Mine burnt to a crisp
although it still shows continuity. It reads about 250 ohms and on the
DMM's Lx function it says 7.0 Hy. Thanks for any help.


I see that Peter Dahl has the specifications for the HQ-180A power
transformer
http://www.pwdahl.com/dahlcatalog/hamtrans011404.html#H

HAMMARLUND HQ-180A POWER
REPLACES P/N P26305-1, 115 VAC PRI ONLY
CORE) EI-125 X 1.75 STYLE #) 06 E-I LAMINATED CORE
PR) 115 VAC 60 HZ 1 PH

S1) 420 VCT @ 200 MA CCS

S2) 6.3 VAC @ 6A CCS

DM) HT = 2.625 WT = 3.750 DT = 3.125 MD = 2.500 MW = 3.125
PRICE) $125.00 Plus S&H FOB El Paso, TX WEIGHT) 6 LBS
================
He may also have the filter choke specifications. IF you have the
original -- they will rework / rebuild it -- to keep size, etc.

gb