What is SINAD?
On Mon, 17 Oct 2005 03:09:11 GMT, Owen Duffy wrote:
So, theoretically:
- an ideal average responding meter should read (1-2/pi)% which is
36.3% or 8.8dB on an perfect square wave;
I think this is close to the right answer, but for the wrong reason. I
think it needs to be evaluated iteratively, and I get an answer closer
to 34.3% or 9.3dB.
Owen
--
|