Reg Edwards wrote:
Sorry! Just to continue and further confuse the haggling, the forward
voltages are unknown because one does not know, in the case of amateur
systems, what is the internal voltage and internal impedance of the
transmitter.


There are an infinite number of internal voltages and internal impedances
that will give the same voltage on the line. All you need to know is the
forward power and reflected power.

It is this unknown voltage and internal impedance which the so-called SWR
(Rho) meter merely ASSUMES.


Pretty easy to measure the forward and reflected powers and take the
square root of Pref/Pfwd to find 'rho' based on those assumptions.
--