View Single Post
  #5   Report Post  
Old August 6th 06, 06:00 AM posted to rec.radio.amateur.boatanchors,rec.radio.shortwave,cornell.marketplace,ithaca.marketplace
m II m II is offline
external usenet poster
 
First recorded activity by RadioBanter: Jul 2006
Posts: 2,053
Default WTB:WTB: power transformer

Lynn Coffelt wrote:


...........big snip.............. Not eloquent, and maybe even a little
hair raising, but if only one short to ground it can be fixed (OK, klutched)
by insulating the transformer core and frame from the chassis.
Lynn, W7LTQ (who does not necessarily recommend this "fix")



That may turn into a dangerous solution.. it's good that you don't
recommend it. I would think that a 'turn to turn' short is more likely
than a turn to frame short.

If there is more than one turn of the winding being shorted, the turns
ratio will be changed, altering the output. The voltage on the out side
goes up if the primary winding count is reduced and it goes down if it's
the secondary windings getting together.





mike